Muzalifah BINTI HAJI Mohd Said

Dr. Muzalifah BINTI HAJI Mohd Said


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2020 in Polymers
Verified
Journal Article
Open access
PDF file
JYJumril Yunas
Jumril Yunas
BMBudi Mulyanti
Budi Mulyanti
IHIda Hamidah
Ida Hamidah
MSMuzalifah BINTI HAJI Mohd Said
Muzalifah BINTI HAJI Mohd Said
RPRoer Eka Pawinanto
Roer Eka Pawinanto
BMBurhanuddin Yeop Majlis
Burhanuddin Yeop Majlis
In this study, we present a comprehensive review of polymer-based microelectromechanical systems (MEMS) electromagnetic (EM) actuators and their implementation in the biomedical engineering field. The purpose of this review is to provide a comprehensive summary on the latest development of electromagnetically driven microactuators for biomedical application that is focused on the movable structure development made of polymers. The discussion does not only focus on the polymeric material part itself, but also covers the basic mechanism of the mechanical actuation, the state of the art of the membrane development and its application. In this review, a clear description about the scheme used to drive the micro-actuators, the concept of mechanical deformation of the movable magnetic membrane and its interaction with actuator system are described in detail. Some comparisons are made to scrutinize the advantages and disadvantages of electromagnetic MEMS actuator performance. The previous studies and explanations on the technology used to fabricate the polymer-based membrane component of the electromagnetically driven microactuators system are presented. The study on the materials and the synthesis method implemented during the fabrication process for the development of the actuators are also briefly described in this review. Furthermore, potential applications of polymer-based MEMS EM actuators in the biomedical field are also described. It is concluded that much progress has been made in the material development of the actuator. The technology trend has moved from the use of bulk magnetic material to using magnetic polymer composites. The future benefits of these compact flexible material employments will offer a wide range of potential implementation of polymer composites in wearable and portable biomedical device applications.

31 December 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
MSMuzalifah BINTI HAJI Mohd Said
Muzalifah BINTI HAJI Mohd Said
JYJumril Yunas
Jumril Yunas
BBBadariah Bais
Badariah Bais
AHAzrul Hamzah
Azrul Hamzah
BMBurhanuddin Yeop Majlis
Burhanuddin Yeop Majlis
A valveless electromagnetic (EM) micropump with a matrix-patterned magnetic polymer composite actuator membrane structure was successfully designed and fabricated. The composite membrane structure is made of polydemethylsiloxane (PDMS) that is mixed with magnetic particles and patterned in matrix blocks. The matrix magnetic composite membrane was fabricated using a soft lithography process and expected to have a compact structure having sufficient magnetic force for membrane deformation and maintained membrane flexibility. The magnetic membrane was integrated with the microfluidic system and functionally tested. The experimental results show that a magnetic composite actuator membrane containing of 6% NdFeB is capable of producing a maximum membrane deflection up to 12.87 µm. The functionality test of the EM actuator for fluid pumping resulted in an extremely low sample injection flow rate of approximately 6.523 nL/min. It was also concluded that there is a correlation between the matrix structure of the actuator membrane and the fluid pumping flow rate. The injection flow rate of the EM micropump can be controlled by adjusting the input power supplied to the EM coil, and this is believed to improve the injection accuracy of the drug dosage and have potential in improving the proficiency of the existing drug delivery system.

29 July 2021 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
JYJumril Yunas
Jumril Yunas
MSMuzalifah BINTI HAJI Mohd Said
Muzalifah BINTI HAJI Mohd Said
RPRoer Eka Pawinanto
Roer Eka Pawinanto
BBBadariah Bais
Badariah Bais
BMBudi Mulyanti
Budi Mulyanti
BMBurhanuddin Yeop Majlis
Burhanuddin Yeop Majlis
In this paper we present the development of electromagnetic (EM) microfluidic pumps incorporating the magnetic polymer composite for the transport of microfluidic bio-sample. The pump system includes the electromagnetic field generator, a flexible actuator membrane made of polymer material with embedded magnetic particles and valve-less microfluidic channel and chamber. The micropump is fabricated using a MEMS process with additional bonding process. Various types of the magnetic membrane as well as electromagnetic coils were fabricated and characterized to find optimum pump performance. As the results, it is found that the fabricated pump systems were able to deliver fluidic sample within a large flow-rate range from 6 ml/min down to several nl/min which can be adjusted by setting the input electrical current parameters, such as intensity, frequency and type of the current signal.

11 November 2024 in International Journal of Academic Research in Business and Social Sciences
Verified
Journal Article
Open access
PDF file
MSMuzalifah BINTI HAJI Mohd Said
Muzalifah BINTI HAJI Mohd Said
FJFaiq Nazeer Jasni
Faiq Nazeer Jasni
SYSiti Aisah Mat Yunos
Siti Aisah Mat Yunos
FHFaiz Harith
Faiz Harith
HRMARS is well established journal publisher based in Pakistan. It is publishing prominent journals in social sciences since 2011.