Dong Zhao

Dr. Dong Zhao


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2018 in Archives of Virology
Verified
Journal Article
Closed access
PDF file
DZDong Zhao
Dong Zhao
XWXiaobo Wang
Xiaobo Wang
QGQingqing Gao
Qingqing Gao
CHChangchao Huan
Changchao Huan
WWWanbin Wang
Wanbin Wang
XLXiufan Liu
Xiufan Liu

9 January 2023 in ACS Omega
Verified
Journal Article
Open access
HWHaoyu Wang
Haoyu Wang
PXPengli Xiao
Pengli Xiao
Shengbo SangShengbo Sang
Shengbo Sang
HCHonglie Chen
Honglie Chen
XDXiushan Dong
Xiushan Dong
DZDong Zhao
Dong Zhao
A factor closely associated with renal disease status in clinical diagnosis is abnormal human serum albumin (HSA) concentration levels in human body fluids urine, serum, etc. The surface stress biosensor was developed as a new type of biosensor to detect protein molecule concentration and has a wide range of clinical applications. However, further sensitivity improvement is required to achieve higher detection performance. Herein, MXene/PDMS/Fe3O4/PDMS of the multilayer heterogeneous membrane biosensor (MHBios) based on the coupling of the magnetic field, electric field, and surface stress field was successfully developed to achieve high sensitivity HSA detection through magnetic sensitization. The modified antibody specifically binds to HSA at the AuNP layer, allowing the biosensor to convert the surface stress caused by PDMS film deformation into an electrical signal. When the biosensor was exposed to a uniform magnetic field, the conductive path of the conductive layer was reshaped further as the magnetic force amplified the deformation of the PDMS film, enhancing the conversion of biological signals to electrical signals. The results exhibited that the detection limit (LOD) of the MHBios was 78 ng/mL when HSA concentration was 0-50 mu g/mL, which was markedly lower than the minimum diagnostic limit of microalbuminuria. Furthermore, the MHBios detected HSA in actual samples, confirming the potential for early disease screening.

17 September 2023 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
DZDong Zhao
Dong Zhao
PXPengli Xiao
Pengli Xiao
XDXiushan Dong
Xiushan Dong
YGYang Ge
Yang Ge
XGXing Guo
Xing Guo
Shengbo SangShengbo Sang
Shengbo Sang
The membrane-mediated magneto-stress-electric-coupled-sensitization biosensor (MSEC-MMB) was developed with a LOD of 24 pg mL−1 for HSA. The biosensor showed a high sensitivity and practicality, providing a platform for early nephropathy diagnosis.

27 July 2023 in Analytical Biochemistry
Verified
Journal Article
Closed access
HCHonglie Chen
Honglie Chen
KYKun Yang
Kun Yang
SSShengbo Sang
Shengbo Sang
XGXing Guo
Xing Guo
YGYang Ge
Yang Ge
DZDong Zhao
Dong Zhao

7 February 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
XGXing Guo
Xing Guo
JHJianru Hou
Jianru Hou
YGYang Ge
Yang Ge
DZDong Zhao
Dong Zhao
Shengbo SangShengbo Sang
Shengbo Sang
Jianlong JiJianlong Ji
Jianlong Ji
The need for Alpha2-Macroglobulin (α2-M) detection has increased because it plays an important role in the diagnosis of diabetic nephropathy (DN). However, few sensors can realize the high-sensitive detection for α2-M with characteristics of being fast, flexible, wearable and portable. Herein, a biosensor based on a MnFe2O4@chitosan/MWCNTs/PDMS composite film was developed for α2-M detection. Due to the excellent magnetoelastic effect of MnFe2O4 nanoparticles, the stress signal of the biosensor surface induced by the specific antibody–antigen binding was transformed into the electrical and magnetic signal. Chitosan-coated MnFe2O4 particles were used to provide biological modification sites for the α2-M antibody, which simplified the conventional biological functionalization modification process. The MnFe2O4@chitosan particles were successfully prepared by a chemical coprecipitation method and the property was studied by TEM, FT-IR and XRD. MWCNTs were employed to enhance electrical conductivity and the sensitivity of the biosensor. The detection limit (LOD) was reduced to 0.1299 ng·mL−1 in the linear range from 10 ng∙mL−1 to 100 µg·mL−1, which was significantly lower than the limit of health diagnostics. The biosensor is fabricated by a simple method, with advantages of being rapid and highly-sensitive, and having selective detection of α2-M, which provides a novel method for the early diagnosis of DN, and it has potential in the point of care (PoC) field.

12 July 2024 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
YLYuanhang Liu
Yuanhang Liu
Shengbo SangShengbo Sang
Shengbo Sang
DZDong Zhao
Dong Zhao
YGYang Ge
Yang Ge
JXJuanjuan Xue
Juanjuan Xue
XGXing Guo
Xing Guo
African swine fever (ASF) is a highly contagious and severe hemorrhagic disease caused by the African swine fever virus (ASFV). The continuous spread of ASFV affects the safety of the global meat supply; therefore, the establishment of sensitive and specific detection methods for ASFV has become an important hot spot in food safety. Herein, we developed a flexible magnetoelastic (ME) biosensor based on PDMS/FeSiB/QDs composite films for the detection of ASFV P72 protein. Based on the high luminescence performance of CsPbBr3 quantum dots and the excellent magnetoelastic effect of FeSiB, flexible ME biosensors convert stress signals generated by antibody–antigen-specific binding into optical and electromagnetic signals. The nanostructures covalently linked by quantum dots and PDMS provide biomodification sites for ASFV P72 antibodies, simplifying the functionalization modification process compared to the case of conventional biosensors. The deformation of the PDMS film is amplified, and the conversion of surface stress signals to electrical signals is enhanced by exposing the biosensor to a uniform magnetic field. The experimental results proved that the flexible ME biosensor has a wide linear range of 10 ng mL−1–100 μg mL−1, and the detection limit is as low as 0.079 ng mL−1. Moreover, the flexible ME biosensor also shows good stability, sensitivity and specificity, confirming the potential for early disease screening.