Yuxiong Huang

Dr. Yuxiong Huang

School of Electric Engineering, Xi’an Jiaotong University, Xi’an 713599, China
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
Yuxiong HuangYuxiong Huang
Yuxiong Huang
GLGengfeng Li
Gengfeng Li
CCChen Chen
Chen Chen
YBYiheng Bian
Yiheng Bian
Tao QianTao Qian
Tao Qian
ZBZhaohong Bie
Zhaohong Bie
Resilience becomes vital for power grids facing the increasingly frequent extreme weather events. Microgrid formation is a promising way to achieve resilient distribution networks (RDN) when the utility power is unavailable. This paper proposes a RDN-oriented microgrid formation (RoMF) method based on the deep reinforcement learning (DRL) technique, which integrates the OpenDSS as an interaction object and searches for optimal control policies in a model-free fashion. Specifically, we formulate the microgrid formation problem as a Markov decision process, taking into account complex factors such as unbalanced three-phase power flow and microgrid operation constraints. Next, a simulator-based RoMF environment is constructed and integrated into the OpenAI Gym, providing a standard agent-environment interface for applying DRL algorithms. Then, the deep Q-network is used to search for optimal microgrid formation strategies, and an offline-training and online-application framework of the DRL-based RoMF is given. Finally, extensive numerical results validate the effectiveness of our proposed method.

21 December 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YBYiheng Bian
Yiheng Bian
CCChen Chen
Chen Chen
Yuxiong HuangYuxiong Huang
Yuxiong Huang
ZBZhaohong Bie
Zhaohong Bie
João P. S. CatalãoJoão P. S. Catalão
João P. S. Catalão
The time required to restore distribution systems following an extreme event is highly dependent on damage assessment. Waiting for field assessors patrolling the feeders to identify fault locations is a bottleneck in improving restoration efficiency. This paper proposes an optimal service restoration model for resilient distribution systems considering the coordination with damage assessment, as a contribution to earlier studies. The restoration actions such as fault isolation, network reconfiguration, crew mobilization and fault repair are brought forward to the damage assessment stage and the restoration schedules are dynamically updated with the reveal of the damage status. The relationship between fault location, switch status and node status is established to optimize the network topology and guarantee crew operation safety under the condition that the network has multiple faults or unchecked potential faulted areas. Moreover, the crew routing formulations are modified to enable fault isolation and load island reconnection by manual switches during the restoration process. Case studies validate the effectiveness of the proposed model in reducing load shedding and restoration duration.

9 July 2019 in Journal of Modern Power Systems and Clean Energy
Verified
Journal Article
Open access
PDF file
GLGengfeng Li
Gengfeng Li
GHGechao Huang
Gechao Huang
ZBZhaohong Bie
Zhaohong Bie
YLYanling Lin
Yanling Lin
Yuxiong HuangYuxiong Huang
Yuxiong Huang
Increasingly frequent natural disasters and man-made malicious attacks threaten the power systems. Improving the resilience has become an inevitable requirement for the development of power systems. The importance assessment of components is of significance for resilience improvement, since it plays a crucial role in strengthening grid structure, designing restoration strategy, and improving resource allocation efficiency for disaster prevention and mitigation. This paper proposes a component importance assessment approach of power systems for improving resilience under wind storms. Firstly, the component failure rate model under wind storms is established. According to the model, system states under wind storms can be sampled by the non-sequential Monte Carlo simulation method. For each system state, an optimal restoration model is then figured out by solving a component repair sequence optimization model considering crew dispatching. The distribution functions of component repair moment can be obtained after a sufficient system state sampling. And Copeland ranking method is adopted to rank the component importance. Finally, the feasibility of the proposed approach is validated by extensive case studies.

27 February 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
GLGengfeng Li
Gengfeng Li
Yuxiong HuangYuxiong Huang
Yuxiong Huang
ZBZhaohong Bie
Zhaohong Bie
Load rebound characteristics (LRC), which means that restoration of distribution systems with large thermostatically controlled load (TCL) after an outage may create significantly higher load demand than normal (namely the demand if this outage does not occur), will make the reliability index-expected energy not supplied (EENS) of distribution systems obtained by traditional methods pessimistic and inaccurate. Since EENS is one of the base points of investment planning for distribution system operator, it is necessary to consider the LRC in the reliability evaluation and provide a more accurate evaluation on EENS. This paper proposed a new reliability evaluation method of smart distribution systems based on a nonnegative k-singular value decomposition (NN-K-SVD) algorithm and a sequential Monte Carlo (SMC) simulation. The NN-K-SVD algorithm is used to identify the TCL in total load. A reliability model considering the LRC is established based on an electric water heater model. The SMC simulation is used to mimic the operation of distribution systems based on the established reliability evaluation model, and calculate reliability indices. Furthermore, the feasibility of the proposed method is validated by extensive cases studies.

6 April 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
GLGengfeng Li
Gengfeng Li
Yuxiong HuangYuxiong Huang
Yuxiong Huang
ZBZhaohong Bie
Zhaohong Bie
TDTao Ding
Tao Ding
Reliability evaluation of power distribution systems is a well‐studied and understood problem, but topology analysis efficiency and failure feature description are still limiting the practical application of reliability evaluation in distribution systems. One approach the authors proposed in this study is to incorporate the machine‐learning technique into the simulation‐based reliability evaluation method, and assess the system reliability in an empirical fashion. In this study, a framework for performing the machine‐learning‐based reliability evaluation, and corresponding modelling processes are first established. Then, by inducing a supervised learning algorithm named perceptron, a state‐space classification‐based (SSC) method for system state assessment, the core procedure of reliability evaluation, is proposed. On this basis, a reliability evaluation algorithm combining the SSC‐based system state assessment and sequential Monte Carlo simulation is proposed, where the workload of topology analysis required in conventional reliability evaluation methods can be released. Furthermore, extensive case studies are conducted on the Roy Billinton Test System (RBTS) bus 2 system and an actual distribution system to verify the proposed models and algorithms. Results show that the proposed framework supports a more efficient reliability evaluation pattern while ensuring the evaluation accuracy.

23 September 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LZLiyin Zhang
Liyin Zhang
GLGengfeng Li
Gengfeng Li
Yuxiong HuangYuxiong Huang
Yuxiong Huang
JJJiangfeng Jiang
Jiangfeng Jiang
ZBZhaohong Bie
Zhaohong Bie
HTHuili Tian
Huili Tian
Residential customer baseline load (CBL) estimation is critical to Demand Response (DR) implementation. The accurate estimation of baseline load is challenging because of the complexity and uncertainty of customer behavior. In addition, conventional methods are based on centralized datasets, which may be unrealistic considering the customer privacy issues and the geographical distribution of data storage under multiple load aggregators (LA). This paper proposes a fully distributed framework for CBL estimation based on joint Fuzzy C-Means (FCM). The fuzzy membership matrix is utilized to capture the load features. LAs can acquire the joint clustering result through limited information exchange in a privacy-preserving way. At last, the CBL is calculated through an inverse process of clustering. Case studies have been conducted utilizing the dynamic Time of Use trail data from Low Carbon London project. Compared with widely used averaging methods, the proposed method significantly improves the estimation accuracy.