This article proposes a single-frequency occultation method whose core is the reconstruction of a second frequency measurement. We process the actual received Galileo E1 single-frequency occultation observation data of FengYun3E to meet the urgent need for single-frequency Galileo occultation inversion of FengYun3 E/F/G/H satellites. Galileo single-frequency occultation events are globally distributed evenly and have stable quantities. The refractive index products and dry temperature products inverted from the single-frequency occultation data are reliable at altitudes of 5–30 km. The Galileo E1 single-frequency occultation process can effectively improve the output of FengYun3E/GNOS occultation products. These results validate the feasibility and correctness of using FengYun3/GNOS for the actual Galileo single-frequency occultation process. The atmospheric occultation products of Galileo single-frequency occultation increase the quantity of global occultation products and serve as a beneficial supplement to global numerical weather prediction data sources.
GNSS single-frequency occultation processing technology has the advantage of simple instrumentation, but it is not clear about the accuracy of the Beidou-based single-frequency occultation processing. This paper verifies the single-frequency occultation processing algorithm of the BeiDou navigation system (BDS) and analyzes its accuracy based on occultation observation data from the FY3E satellite. The research aimed to verify the single-frequency ionospheric relative total electron content (relTEC), analyze the accuracy of the reconstructed second frequency ’s excess phase Doppler, and analyze the accuracy of the refractive index products. Results: (1) As for relTEC and excess phase Doppler, the correlation coefficient between single-frequency occultation processing and dual-frequency occultation processing is greater than 0.95. (2) The relative average deviations of the excess phase Doppler of are mostly less than 0.2%, and the relative standard deviations are mostly around 0.5%. (3) The bias index and root mean square index of single/dual-frequency inversion have good consistency compared with ERA5 data. All the results show that the single- and dual-frequency inversion refractive index products have comparable accuracies, and the accuracy of the standard deviation of single-frequency inversion refractive index products over 25 km being slightly lower than that of dual-frequency inversion refractive index products.