BNSL Manjeera Vinnakota

Mrs. BNSL Manjeera Vinnakota


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
BVBNSL Manjeera Vinnakota
BNSL Manjeera Vinnakota
Kishan BellurKishan Bellur
Kishan Bellur
SSSandra L. Starnes
Sandra L. Starnes
MSMark Schulz
Mark Schulz
Aligned with the medical device industry’s trend of miniaturization, academic and commercial researchers are constantly attempting to reduce device sizes. Many applications require miniature actuators (2 mm range) to perform mechanical work; however, biocompatible micromotors are not readily available. To that end, a hydraulic motor-driven cutting module that aims to combine cutting and drug delivery is presented. The hydraulic motor prototype developed has an outside diameter (OD) of ~4 mm (twice the target size) and a 1 mm drive shaft to attach a cutter. Four different designs were explored and fabricated using additive manufacturing. The benchtop experimental data of the prototypes are presented herein. For the prototype motor with fluid inlet perpendicular to the blades, the average angular velocity was 10,593 RPM at a flowrate of 3.6 mL/s and 42,597 RPM at 10.1 mL/s. This design was numerically modeled using 3D-transient simulations in ANSYS CFX (version 2022 R2) to determine the performance characteristics and the internal resistance of the motor. Simplified mathematical models were also used to compute and compare the peak torque with the simulation estimates. The viability of current design represents a crucial milestone in scaling the hydraulic motor to a 2 mm OD to power a microcutter.

29 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
BVBNSL Manjeera Vinnakota
BNSL Manjeera Vinnakota
Kishan BellurKishan Bellur
Kishan Bellur
SSSandra L. Starnes
Sandra L. Starnes
MSMark Schulz
Mark Schulz
Miniaturization of multifunctional instruments is key to evolving less invasive medical procedures. The current work outlines steps towards developing a miniature motor to power a cutting tool of a millimeter-scale robot/device (target outside diameter ~2 mm) for minimally invasive procedures. Multiple motor concepts were explored and ranked using a Pugh matrix. The single-rotor hydraulic design was deemed most viable for prototyping and scale-down to the target size. Prototypes were manufactured to be progressively smaller using additive manufacturing. The smallest prototype fabricated was 2:1 scale of the desired final size with a 2 mm outside diameter (OD) rotor and a device OD of 4 mm. The scaled prototypes with an 8 mm rotor were lab tested and achieved average speeds of 5000–6000 RPM at a flowrate of 15–18 mL/s and 45 PSI water pressure. Ansys CFX was used as a design tool to explore the parameter space and 3D transient simulations were implemented using the immersed solid method. The predicted rotor RPM from the modeling matched the experimental values within 3% error. The model was then used to develop performance curves for the miniature hydraulic motor. In summary, the single-rotor hydraulic design shows promise for miniaturization to the target 2 mm size.

23 January 2025 in Discover Mechanical Engineering
Verified
Journal Article
Open access
PDF file
BVBNSL Manjeera Vinnakota
BNSL Manjeera Vinnakota
Kishan BellurKishan Bellur
Kishan Bellur
SSSandra L. Starnes
Sandra L. Starnes
MSMark Schulz
Mark Schulz
To address the challenges of biopsy and intratumoral drug delivery using microdevices, a miniature multifunctional tethered device that has tissue cutting, biopsy and drug delivery capabilities is presented in this paper. The cutting module in the prototype is hydraulically powered and has an outside diameter (OD) of 2 mm at the tip and a cutter attached to 500 µm drive shaft. The hydraulic micromotor prototype was fabricated using micro additive manufacturing. It was tested using a benchtop set-up and had an average speed greater than 100,000 RPM at a water flowrate of 45 mL/min and a speed of about 34,000 RPM at 15 mL/min flowrate. This micromotor design was numerically modeled using 3D-transient simulations in ANSYS CFX to determine its performance characteristics and internal resistance. Preliminary testing was performed using cutting modules with five cutter geometries on agar tissue phantoms of different concentrations and other biological materials. The dissection ability of the cutting module, its ability to deliver particles, and collect biopsy samples were successfully demonstrated. Scaling the 2 mm OD device further, a 1 mm OD micromotor, with a nominal output shaft diameter of 250 µm, was fabricated and operated with air establishing the proof of concept. Graphical Abstract