Jean-David Werthel

Dr. Jean-David Werthel

Service d’Orthopédie et de Traumatologie, Hôpital Ambroise Paré, Boulogne-Billancourt, France

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2019 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
JWJean-David Werthel
Jean-David Werthel
GWGilles Walch
Gilles Walch
EVEmilie Vegehan
Emilie Vegehan
PDPierric DERANSART
Pierric DERANSART
JSJoaquin Sanchez-Sotelo
Joaquin Sanchez-Sotelo
PVPhilippe Valenti
Philippe Valenti

20 November 2018 in Obere Extremität
Verified
Journal Article
Open access
PDF file
PVPhilippe Valenti
Philippe Valenti
JWJean-David Werthel
Jean-David Werthel
Background Lower trapezius transfer can restore external rotation in brachial plexus palsies. In some cuff tear arthropathies, there is lack of active external rotation with a preservation of forward elevation. We evaluated the clinical outcomes of a lower trapezius transfer extended with a semitendinosus tendon and fixed to the insertion of the infraspinatus via arthroscopy. Methods Between 2013 and 2016, we operated on 14 patients (8 men, 6 women; mean age of 62 years, range: 50–70) to reconstruct irreparable posterosuperior rotator cuff tear. A vertical incision of 6 cm following the medial border of the spine was made to harvest the lower trapezius in extension with the semitendinosus tendon. The extension band of the lower trapezius was fixed laterally via arthroscopy on the great tuberosity at the level of the insertion of the infraspinatus. The proximal stump of this extension band was then fixed medially into the muscle of the lower trapezius with the arm in maximum external rotation. Outcomes were evaluated with the Constant–Murley score, simple shoulder test (SST), and subjective shoulder value (SSV). Results Over a mean follow-up of 24 months (range: 12–36 months), the gain in external rotation with the arm at the side was 24° and 40° in 90° of abduction. The Constant–Murley score improved from 35 to 60 points, the SST from 3.5 to 7.5, the SSV from 30 to 60%, and the pain decreased from 7 to 2 (visual analogue scale, 0–10). Both the lag sign and hornblower sign were negative after this transfer. There were two cases of hematomas, and one was revised because of infection. Conclusion Lower trapezius transfer is a therapeutic option for irreparable posterosuperior cuff tears with a lack of active external rotation and a good subscapularis. Patients can expect improvements in pain and in active external rotation without any loss of active anterior elevation.

1 January 2018 in Journal of Shoulder and Elbow Arthroplasty
Verified
Journal Article
Open access
JWJean-David Werthel
Jean-David Werthel
BSBradley S Schoch
Bradley S Schoch
SVSteven C van Veen
Steven C van Veen
BEBassem T Elhassan
Bassem T Elhassan
KAKai-Nan An
Kai-Nan An
JSJohn W Sperling
John W Sperling
The purpose of this study is to assess the incidence of acromial stress fractures in a population of reverse shoulder arthroplasties (RSA) and determine potential risk factors for fracture. Between August 2004 and December 2013, 1082 primary RSA were performed at a single institution. Twelve (1.11%) patients were diagnosed with a postoperative acromial stress fracture. This group was case-matched to a control group of 48 shoulders. Clinical and radiographic risk factors for fracture were assessed. Compared to controls, fractures were less satisfied with their outcome despite equivalent American Shoulder and Elbow Surgeons scores, pain scores, and range of motion. Osteoporosis was significantly associated with acromial fractures (P = .027). A smaller lateral offset of the greater tuberosity, greater arm lengthening, and a thinner acromion were more common in the fracture group (P = .026, P = .004, and P = .008, respectively). In summary, postoperative acromial stress fractures appear to be incidental lesions with little influence on the outcome after RSA. The combination of a thin acromion and superior migration of the humeral head increase the risk of acromial fracture. Lateralized designs that do not excessively verticalize the deltoid line of pull on the acromion may decrease the risk of postoperative acromial fractures.

26 December 2019 in The American Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
JWJean-David Werthel
Jean-David Werthel
VSVincent Sabatier
Vincent Sabatier
BSBradley Schoch
Bradley Schoch
LALior Amsallem
Lior Amsallem
GNGeoffroy Nourissat
Geoffroy Nourissat
AHAlexandre Hardy
Alexandre Hardy
It remains unclear whether results differ between a Latarjet procedure performed after a failed arthroscopic Bankart repair and one performed as the primary operation. To compare the postoperative outcomes of the Latarjet procedure when performed as primary surgery and as revision for a failed arthroscopic Bankart repair. Cohort study; Level of evidence, 3. A multicenter retrospective comparative case-cohort analysis was performed for all patients undergoing a Latarjet procedure for recurrent anterior shoulder instability. Patients were separated into 2 groups depending on if the Latarjet procedure was performed after a failed arthroscopic Bankart repair (group 1) or as the first operation (group 2). Outcome measures included recurrent instability, reoperation rates, complications, pain, Walch-Duplay scores, and Simple Shoulder Test. A total of 308 patients were eligible for participation in the study; 72 (23.4%) did not answer and were considered lost to follow-up, leaving 236 patients available for analysis. Mean follow-up was 3.4 ± 0.8 years. There were 20 patients in group 1 and 216 in group 2. Despite similar rates of recurrent instability (5.0% in group 1 vs 2.3% in group 2; P = .5) and revision surgery (0% in group 1 vs 6.5% in group 2; P = .3), group 1 demonstrated significantly worse pain scores (2.56 ± 2.7 vs 1.2 ± 1.7; P = .01) and patient-reported outcomes (Walch-Duplay: 52 ± 25.1 vs 72.2 ± 25.0; P = .0007; Simple Shoulder Test: 9.3 ± 2.4 vs 10.7 ± 1.9; P = .001) when compared with those patients undergoing primary Latarjet procedures. Functional outcome scores and postoperative pain are significantly worse in patients undergoing a Latarjet procedure after a failed arthroscopic Bankart repair when compared with patients undergoing primary Latarjet. The assumption that a failed a Bankart repair can be revised by a Latarjet with a similar result to a primary Latarjet appears to be incorrect. Surgeons should consider these findings when deciding on the optimal surgical procedure for recurrent shoulder instability.

1 December 2021 in Orthopaedics & Traumatology: Surgery & Research
Verified
Journal Article
Closed access
JWJean-David Werthel
Jean-David Werthel
MVMarie Vigan
Marie Vigan
BSBradley Schoch
Bradley Schoch
ALAlexandre Lädermann
Alexandre Lädermann
GNGeoffroy Nourissat
Geoffroy Nourissat
CCChristel Conso
Christel Conso

20 October 2021 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PMPhilipp Moroder
Philipp Moroder
MUManuel Meng Urvoy
Manuel Meng Urvoy
PRPatric Raiss
Patric Raiss
JWJean-David Werthel
Jean-David Werthel
DADoruk Akgun
Doruk Akgun
PSPaul Siegert
Paul Siegert
Background: Component selection and placement in reverse total shoulder arthroplasty (RTSA) is still being debated. Recently, scapulothoracic orientation and posture have emerged as relevant factors when planning an RTSA. However, the degree to which those parameters may influence ROM and whether modifiable elements of implant configuration may be helpful in improving ROM among patients with different postures have not been thoroughly studied, and modeling them may be instructive. Questions/purposes: Using a dedicated expansion of a conventional preoperative planning software, we asked: (1) How is patient posture likely to influence simulated ROM after virtual RTSA implantation? (2) Do changes in implant configuration, such as humeral component inclination and retrotorsion, or glenoid component size and centricity improve the simulated ROM after virtual RTSA implantation in patients with different posture types? Methods: In a computer laboratory study, available whole-torso CT scans of 30 patients (20 males and 10 females with a mean age of 65 ± 17 years) were analyzed to determine the posture type (Type A, upright posture, retracted scapulae; Type B, intermediate; Type C, kyphotic posture with protracted scapulae) based on the measured scapula internal rotation as previously described. The measurement of scapular internal rotation, which defines these posture types, was found to have a high intraclass correlation coefficient (0.87) in a previous study, suggesting reliability of the employed classification. Three shoulder surgeons each independently virtually implanted a short, curved, metaphyseal impaction stem RTSA in each patient using three-dimensional (3D) preoperative surgical planning software. Modifications based on the original component positioning were automatically generated, including different humeral component retrotorsion (0°, 20°, and 40° of anatomic and scapular internal rotation) and neck-shaft angle (135°, 145°, and 155°) as well as glenoid component configuration (36-mm concentric, 36-mm eccentric, and 42-mm concentric), resulting in 3720 different RTSA configurations. For each configuration, the maximum potential ROM in different planes was determined by the software, and the effect of different posture types was analyzed by comparing subgroups. Results: Irrespective of the RTSA implant configuration, the posture types had a strong effect on the calculated ROM in all planes of motion, except for flexion. In particular, simulated ROM in patients with Type C compared with Type A posture demonstrated inferior adduction (median 5° [interquartile range -7° to 20°] versus 15° [IQR 7° to 22°]; p < 0.01), abduction (63° [IQR 48° to 78°] versus 72° [IQR 63° to 82°]; p < 0.01), extension (4° [IQR -8° to 12°] versus 19° [IQR 8° to 27°]; p < 0.01), and external rotation (7° [IQR -5° to 22°] versus 28° [IQR 13° to 39°]; p < 0.01). Lower retrotorsion and a higher neck-shaft angle of the humeral component as well as a small concentric glenosphere resulted in worse overall ROM in patients with Type C posture, with severe restriction of motion in adduction, extension, and external rotation to below 0°. Conclusion: Different posture types affect the ROM after simulated RTSA implantation, regardless of implant configuration. An individualized choice of component configuration based on scapulothoracic orientation seems to attenuate the negative effects of posture Type B and C. Future studies on ROM after RTSA should consider patient posture and scapulothoracic orientation. Clinical Relevance: In patients with Type C posture, higher retrotorsion, a lower neck-shaft angle, and a larger or inferior eccentric glenosphere seem to be advantageous.