This paper describes an evaluation framework that allows a standardized and objective quantitative comparison of carotid artery lumen segmentation and stenosis grading algorithms. We describe the data repository comprising 56 multi-center, multi-vendor CTA datasets, their acquisition, the creation of the reference standard and the evaluation measures. This framework has been introduced at the MICCAI 2009 workshop 3D Segmentation in the Clinic: A Grand Challenge III, and we compare the results of eight teams that participated. These results show that automated segmentation of the vessel lumen is possible with a precision that is comparable to manual annotation. The framework is open for new submissions through the website http://cls2009.bigr.nl.
Object: Surface-based registration (SBR) with facial surface scans has been proposed as an alternative for the commonly used fiducial-based registration in image-guided neurosurgery. Recent studies comparing the accuracy of SBR and fiducial-based registration have been based on a few targets located on the head surface rather than inside the brain and have yielded contradictory conclusions. Moreover, no visual feedback is provided with either method to inform the surgeon about the estimated target registration error (TRE) at various target locations. The goals in the present study were: 1) to quantify the SBR error in a clinical setup, 2) to estimate the targeting error for many target locations inside the brain, and 3) to create a map of the estimated TRE values superimposed on a patient's head image. Methods: The authors randomly selected 12 patients (8 supine and 4 in a lateral position) who underwent neurosurgery with a commercial navigation system. Intraoperatively, scans of the patients' faces were acquired using a fast 3D surface scanner and aligned with their preoperative MR or CT head image. In the laboratory, the SBR accuracy was measured on the facial zone and estimated at various intracranial target locations. Contours related to different TREs were superimposed on the patient's head image and informed the surgeon about the expected anisotropic error distribution. Results: The mean surface registration error in the face zone was 0.9 ± 0.35 mm. The mean estimated TREs for targets located 60, 105, and 150 mm from the facial surface were 2.0, 3.2, and 4.5 mm, respectively. There was no difference in the estimated TRE between the lateral and supine positions. The entire registration procedure, including positioning of the scanner, surface data acquisition, and the registration computation usually required < 5 minutes. Conclusions: Surface-based registration accuracy is better in the face and frontal zones, and error increases as the target location lies further from the face. Visualization of the anisotropic TRE distribution may help the surgeon to make clinical decisions. The observed and estimated accuracies and the intraoperative registration time show that SBR using the fast surface scanner is practical and feasible in a clinical setup.
Purpose: To characterize fast and slow diffusion components in diffusion‐weighted magnetic resonance imaging (DW‐MRI) of pediatric Crohn's disease (CD). Overall diffusivity reduction as measured by the apparent diffusion coefficient (ADC) in patients with CD has been previously demonstrated. However, the ADC reduction may be due to changes in either fast or slow diffusion components. In this study we distinguished between the fast and slow diffusion components in the DW‐MRI signal decay of pediatric CD.Materials and Methods: We acquired MRI from 24 patients, including MR enterography (MRE) and DW‐MRI with 8 b‐values (0–800 s/mm2). We characterized fast and slow diffusivity by intravoxel incoherent motion (IVIM) model parameters (f, D*, D), and overall diffusivity by ADC values. We determined which model best described the DW‐MRI signal decay. We assessed the influence of the IVIM model parameters on the ADC. We evaluated differences in model parameter values between the enhancing and nonenhancing groups.Results: The IVIM model described the observed data significantly better than the ADC model (P = 0.0088). The ADC was correlated with f (r = 0.67, P = 0.0003), but not with D (r = 0.39, P = 0.062) and D* (r = −0.39, P = 0.057). f values were significantly lower (P < 0.003) and D* values were significantly higher (P = 0.03) in the enhancing segments, while D values were not significantly different between the groups (P = 0.14).Conclusion: For this study population the IVIM model provides a better description of the DW‐MRI signal decay than the ADC model. The reduced ADC is related to changes in the fast diffusion rather than to changes in the slow diffusion. J. Magn. Reson. Imaging 2013;37:156–163.
24 October 2018 in Journal of Magnetic Resonance Imaging