Christian J. Kähler

Prof. Dr. Christian J. Kähler

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2012 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
CKChristian J. Kähler
Christian J. Kähler
SSSven Scharnowski
Sven Scharnowski
CCChristian Cierpka
Christian Cierpka
The reliable measurement of mean flow properties near walls and interfaces between different fluids or fluid and gas phases is a very important task, as well as a challenging problem, in many fields of science and technology. Due to the decreasing concentration of tracer particles and the strong flow gradients, these velocity measurements are usually biased. To investigate the reason and the effect of the bias errors systematically, a detailed theoretical analysis was performed using window-correlation, singe-pixel ensemble-correlation and particle tracking evaluation methods. The different findings were validated experimentally for microscopic, long-range microscopic and large field imaging conditions. It is shown that for constant flow gradients and homogeneous particle image density, the bias errors are usually averaged out. This legitimates the use of these techniques far away from walls or interfaces. However, for inhomogeneous seeding and/or nonconstant flow gradients, only PTV image analysis techniques give reliable results. This implies that for wall distances below half an interrogation window dimension, the singe-pixel ensemble-correlation or PTV evaluation should always be applied. For distances smaller than the particle image diameter, only PTV yields reliable results.

21 February 2012 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
CKChristian J. Kähler
Christian J. Kähler
SSSven Scharnowski
Sven Scharnowski
CCChristian Cierpka
Christian Cierpka
This work analyzes the spatial resolution that can be achieved by digital particle image velocimetry (DPIV) as a function of the tracer particles and the imaging and recording system. As the in-plane resolution for window-correlation evaluation is related by the interrogation window size, it was assumed in the past that single-pixel ensemble-correlation increases the spatial resolution up to the pixel limit. However, it is shown that the determining factor limiting the resolution of single-pixel ensemble-correlation are the size of the particle images, which is dependent on the size of the particles, the magnification, the f-number of the imaging system, and the optical aberrations. Furthermore, since the minimum detectable particle image size is determined by the pixel size of the camera sensor in DPIV, this quantity is also considered in this analysis. It is shown that the optimal magnification that results in the best possible spatial resolution can be estimated from the particle size, the lens properties, and the pixel size of the camera. Thus, the information provided in this paper allows for the optimization of the camera and objective lens choices as well as the working distance for a given setup. Furthermore, the possibility of increasing the spatial resolution by means of particle tracking velocimetry (PTV) is discussed in detail. It is shown that this technique allows to increase the spatial resolution to the subpixel limit for averaged flow fields. In addition, PTV evaluation methods do not show bias errors that are typical for correlation-based approaches. Therefore, this technique is best suited for the estimation of velocity profiles.

23 May 2016 in Experiments in Fluids
Verified
Journal Article
Open access
PDF file
CKChristian J. Kähler
Christian J. Kähler
TATommaso Astarita
Tommaso Astarita
PVPavlos P. Vlachos
Pavlos P. Vlachos
JSJun Sakakibara
Jun Sakakibara
RHRainer Hain
Rainer Hain
CCChristian Cierpka
Christian Cierpka
In the last decade, worldwide PIV development efforts have resulted in significant improvements in terms of accuracy, resolution, dynamic range and extension to higher dimensions. To assess the achievements and to guide future development efforts, an International PIV Challenge was performed in Lisbon (Portugal) on July 5, 2014. Twenty leading participants, including the major system providers, i.e., Dantec (Denmark), LaVision (Germany), MicroVec (China), PIVTEC (Germany), TSI (USA), have analyzed 5 cases. The cases and analysis explore challenges specific to 2D microscopic PIV (case A), 2D time-resolved PIV (case B), 3D tomographic PIV (cases C and D) and stereoscopic PIV (case E). During the event, 2D macroscopic PIV images (case F) were provided to all 80 attendees of the workshop in Lisbon, with the aim to assess the impact of the user’s experience on the evaluation result. This paper describes the cases and specific algorithms and evaluation parameters applied by the participants and reviews the main results. For future analysis and comparison, the full image database will be accessible at http://www.pivChallenge.org.

23 July 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
RBRune Barnkob
Rune Barnkob
CKChristian J. Kähler
Christian J. Kähler
Massimiliano RossiMassimiliano Rossi
Massimiliano Rossi
A General Defocusing Particle Tracking (GDPT) method is proposed for tracking the three-dimensional motion of particles in Lab-on-a-chip systems based on a set of calibration images and the normalized cross-correlation function. In comparison with other single-camera defocusing particle-tracking techniques, GDPT possesses a series of key advantages: it is applicable to particle images of arbitrary shapes, it is intuitive and easy to use, it can be used without advanced knowledge of optics and velocimetry theory, it is robust against outliers and overlapping particle images, and it requires only equipment which is standard in microfluidic laboratories. We demonstrate the method by tracking the three-dimensional motion of 2 μm spherical particles in a microfluidic channel using three different optical arrangements. The position of the particles was measured with an estimated uncertainty of 0.1 μm in the in-plane direction and 2 μm in the depth direction for a measurement volume of 1510 × 1270 × 160 μm3. A ready-to-use GUI implementation of the method can be acquired on http://www.unibw.de/lrt7/gdpt.

30 August 2008 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
RHRainer Hain
Rainer Hain
CKChristian J. Kähler
Christian J. Kähler
DMDirk Michaelis
Dirk Michaelis

23 September 2008 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
WZWei Zhang
Wei Zhang
RHRainer Hain
Rainer Hain
CKChristian J. Kähler
Christian J. Kähler