Renaud Sales

Dr. Renaud Sales

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
QDQuentin Durand
Quentin Durand
CSChris Serrand
Chris Serrand
RSRenaud Sales
Renaud Sales
FOFabien de Oliveira
Fabien de Oliveira
julien frandonjulien frandon
julien frandon
The study’s aim was to assess the impact of a deep learning image reconstruction algorithm (Precise Image; DLR) on image quality and liver metastasis conspicuity compared with an iterative reconstruction algorithm (IR). This retrospective study included all consecutive patients with at least one liver metastasis having been diagnosed between December 2021 and February 2022. Images were reconstructed using level 4 of the IR algorithm (i4) and the Standard/Smooth/Smoother levels of the DLR algorithm. Mean attenuation and standard deviation were measured by placing the ROIs in the fat, muscle, healthy liver, and liver tumor. Two radiologists assessed the image noise and image smoothing, overall image quality, and lesion conspicuity using Likert scales. The study included 30 patients (mean age 70.4 ± 9.8 years, 17 men). The mean CTDIvol was 6.3 ± 2.1 mGy, and the mean dose-length product 314.7 ± 105.7 mGy.cm. Compared with i4, the HU values were similar in the DLR algorithm at all levels for all tissues studied. For each tissue, the image noise significantly decreased with DLR compared with i4 (p < 0.01) and significantly decreased from Standard to Smooth (−26 ± 10%; p < 0.01) and from Smooth to Smoother (−37 ± 8%; p < 0.01). The subjective image assessment confirmed that the image noise significantly decreased between i4 and DLR (p < 0.01) and from the Standard to Smoother levels (p < 0.01), but the opposite occurred for the image smoothing. The highest scores for overall image quality and conspicuity were found for the Smooth and Smoother levels.

27 May 2025 in Research in Diagnostic and Interventional Imaging
Verified
Journal Article
Open access
Joel GREFFIERJoel GREFFIER
Joel GREFFIER
MPMaxime Pastor
Maxime Pastor
QDQuentin Durand
Quentin Durand
RSRenaud Sales
Renaud Sales
CSChris Serrand
Chris Serrand
JFJulien Frandon
Julien Frandon
To compare the impact of a deep-learning image reconstruction algorithm (Precise Image) with an iterative reconstruction algorithm on image quality and detection of solid lung lesions in chest CT images. All consecutive patients with at least one solid lung lesion diagnosed between December 2021 and February 2022 were retrospectively included. Images were reconstructed using Level 4 of the iterative reconstruction algorithm (i4) and the Standard/Smooth/Smoother levels of the deep-learning image reconstruction algorithm. Mean attenuation and standard deviation were measured by placing regions of interest in fat, muscle, trachea and solid lung lesions. The contrast-to-noise ratio between the lesion and the trachea was computed. Two radiologists assessed image noise and image smoothness, overall image quality and confidence diagnostic level using Likert scales. One radiologist also measured the large axis of the largest lesion. Statistical analyses was performed to compare outcomes obtained with the different algorithms. Thirty patients with a mean age of 70.0 ± 9.0 years (17 men) were included. The mean CTDIvol was 6.3 ± 2.1 mGy. For all tissues, the contrast-to-noise ratio was similar for i4 and Standard level (p > 0.05) but increased significantly with other deep-learning image reconstruction levels compared to i4 (p < 0.05) and increased significantly from Standard to Smoother. Radiologists rated the image noise with a similar score between i4 and Standard level but decreased significantly between i4 and other deep-learning image reconstruction levels (p < 0.05) and from Standard to Smoother levels (p < 0.01). Overall image quality score were highest for the Smooth and Smoother levels. Smooth and Smoother levels may now be used in clinical practice for chest CT acquisitions in solid lung lesion follow-up.