Ahmad Yaseen Abdulrazzak

Mr. Ahmad Yaseen Abdulrazzak


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2024 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
AAAhmad Yaseen Abdulrazzak
Ahmad Yaseen Abdulrazzak
SMSaleem Latif Mohammed
Saleem Latif Mohammed
Ali Al-NajiAli Al-Naji
Ali Al-Naji
Javaan ChahlJavaan Chahl
Javaan Chahl
Introduction: Despite the many attempts made by researchers to diagnose jaundice non-invasively using machine learning techniques, the low amount of data used to build their models remains the key factor limiting the performance of their models. Objective: To build a system to diagnose neonatal jaundice non-invasively based on machine learning algorithms created based on a dataset comprising 767 infant images using a computer device and a USB webcam. Methods: The first stage of the proposed system was to evaluate the performance of four machine learning algorithms, namely support vector machine (SVM), k nearest neighbor (k-NN), random forest (RF), and extreme gradient boost (XGBoost), based on a dataset of 767 infant images. The algorithm with the best performance was chosen as the classifying algorithm in the developed application. The second stage included designing an application that enables the user to perform jaundice detection for a patient under test with the minimum effort required by capturing the patient’s image using a USB webcam. Results: The obtained results of the first stage of the machine learning algorithms evaluation process indicated that XGBoost outperformed the rest of the algorithms by obtaining an accuracy of 99.63%. The second-best algorithm was the RF algorithm, which had an accuracy of 98.99%. Following RF, with a slight difference, was the k-NN algorithm. It achieved an accuracy of 98.25%. SVM scored the lowest performance among the above three algorithms, with an accuracy of 96.22%. Based on these obtained results, the XGBoost algorithm was chosen to be the classifier of the proposed system. In the second stage, the jaundice application was designed based on the model created by the XGBoost algorithm. This application ensured it was user friendly with as fast a processing time as possible. Conclusion: Early detection of neonatal jaundice is crucial due to the severity of its complications. A non-invasive system using a USB webcam and an XGBoost machine learning technique was proposed. The XGBoost algorithm achieved 99.63% accuracy and successfully diagnosed 10 out of 10 NICU infants with very little processing time. This denotes the efficiency of machine learning algorithms in healthcare in general and in monitoring systems specifically.

5 July 2023 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
AAAhmad Yaseen Abdulrazzak
Ahmad Yaseen Abdulrazzak
SMSaleem Latif Mohammed
Saleem Latif Mohammed
Ali Al-NajiAli Al-Naji
Ali Al-Naji
Neonatal jaundice is a prevalent condition among newborns, with potentially severe complications that can result in permanent brain damage if left untreated during its early stages. The existing approaches for jaundice detection involve invasive procedures such as blood sample collection, which can inflict pain and distress on the patient, and may give rise to additional complications. Alternatively, a non-invasive method using image-processing techniques and implementing kNN, Random Forest, and XGBoost machine learning algorithms as a classifier can be employed to diagnose jaundice, necessitating a comprehensive database of infant images to achieve a diagnosis with high accuracy. This data article presents the NJN collection, a repository of newborn images encompassing diverse birthweights and skin tones, spanning an age range of 2 to 8 days. The dataset is accompanied by an Excel sheet file in CSV format containing the RGB and YCrCb channel values, as well as the status of each sample. The dataset and associated resources are openly accessible at Zenodo website. Moreover, the Python code for data testing utilizing various AI techniques is provided. Consequently, this article offers an unparalleled resource for AI researchers, enabling them to train their AI systems and develop algorithms that can assist neonatal intensive care unit (NICU) healthcare specialists in monitoring neonates while facilitating the fast, real-time, non-invasive, and accurate diagnosis of jaundice.

31 March 2023 in Journal of Techniques
Verified
Journal Article
Open access
PDF file
AAAhmad Yaseen Abdulrazzak
Ahmad Yaseen Abdulrazzak
SMSaleem Latif Mohammed
Saleem Latif Mohammed
AAAli Al-Naji
Ali Al-Naji
JCJavaan Chahl
Javaan Chahl
At the beginning of their lives, newborns may have a widespread condition known as Jaundice or Hyperbilirubinemia. High levels of bilirubin in the blood are the primary cause of jaundice. Severe cases of jaundice may cause acute bilirubin encephalopathy due to the toxicity of bilirubin to the cells of the brain, which may lead to kernicterus. Kernicterus causes several symptoms, including a permanent upward look, loss of hearing, and repetitive and uncontrolled movements. Therefore, diagnosing this condition at the appropriate time helps to prevent chronic effects. In this study, jaundice or hyperbilirubinemia is diagnosed using a computer vision system based on a random forest algorithm. The system comprises a digital HD camera, a computer device with a Matlab application installed to analyze and detect the skin color changes of the infant, and an Arduino Uno microcontroller to control an LED ultraviolet light. A set of neonate images were collected to train the random forest algorithm, including 374 for normal and 137 for jaundiced infants. |The experimental results using the random forest algorithm for classification reached an accuracy of 98.4375%. The results of this study are promising and open doors for new monitoring applications in various medical diseases detection with a high degree of accuracy.