Karolis Senvaitis

Mr. Karolis Senvaitis


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KSKarolis Senvaitis
Karolis Senvaitis
AAAušra Adomavičienė
Aušra Adomavičienė
ATAlina Tomaševič
Alina Tomaševič
RKRadvilė Kernagytė
Radvilė Kernagytė
APAda Petrauskaitė
Ada Petrauskaitė
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
This study includes an ergonomic evaluation of patient lifting motion performed by healthcare specialists. This analysis focuses on the neck, shoulder, and elbow, as these are statistically significant areas with insufficient research data. Data collection was conducted using the Movella Xsens system as a standard 17 IMU (inertia measurement unit) marker set. A total of 44 test subjects participated, resulting in 396 measurements. A mathematical model was presented, including the main expressions and a three-dimensional moment arm of the shoulder calculation determining both the moment and accumulated moment. The patient load profile was measured in the experiment and parametrically integrated into the mathematical model. Ergonomic limits were calculated and presented, showing that during the lifting motion, the neck exceeds its ergonomic limit by 66%, the shoulders by 49%, and the elbow by 76%. The accumulated moment can vary by up to 23% depending on different evaluated techniques or data cross-sections. The model was verified by comparing it with data from other experiments, and recommendations were presented based on the findings, along with suggestions for future research development in the area.

15 May 2023 in Machines
Verified
Journal Article
Open access
PDF file
KSKarolis Senvaitis
Karolis Senvaitis
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
As musculoskeletal modeling improves, the possibilities of calculating more diverse parameters or performing specific motion analyses increase. However, customization might require a different approach that is not offered by the original software or it requires complex knowledge. Patient lift motion was analyzed in Plug-in-Gait (PiG) marker-set-based kinematic model in Rhino Grasshopper for the range of motion calculation of arms. The model was compared with the biomechanics of body (BoB) 10.5 software kinematic model. For the analyzed model, RMSE evaluated as a percentage of the amplitude varied from 9.17% to 32.44%. The data showed actively accurate results except for a few values that were defined as moderately accurate. All data sets showed strong correlation with the reference model. The tested model was confirmed, since it showed significant data correlation with relative accurate values and was evaluated as suitable for further development and analysis before being put to practical use.

1 June 2024 in Acta Mechanica et Automatica
Verified
Journal Article
Open access
PDF file
KSKarolis Senvaitis
Karolis Senvaitis
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
AAAušra Adomavičienė
Aušra Adomavičienė
This study examines the ergonomics of the patient lifting motion often used by healthcare professionals, focusing on the shoulder area, as manual weight management is still an important part of daily work. Data acquisition was made with the 17 IMU sensors, Movella Xsens system. A total of 25 quality measurements were acquired for further data processing. A mathematical model with the defined assumptions is presented in this research calculating shoulder moment-kinematics. The load engagement profile was determined based on the hip extension as a variable size for different test subjects and trials. Shoulder flexion-extension range of motion (ROM) variance was estimated, determining each test subject’s technique, together with shoulder moment and cumulative shoulder moment. Cumulative shoulder load varied from -31.46% to 27.78% from the mean shoulder moment value. During the estimated accumulation of a 5-year work span, the difference in worst to best techniques accumulated to 1.86 times. Recommendations on how the technique and the further scope of the research could be improved were given.

14 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KSKarolis Senvaitis
Karolis Senvaitis
AAAušra Adomavičienė
Aušra Adomavičienė
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
This study includes musculoskeletal disorder (MSD) risk evaluation based on the IMU sensor data gathered from patient-lifting movement performed by healthcare specialists. This is a continuation of previous research focusing on a novel multicriteria statistical model integrating experimental and large-scale statistical datasets. The proposed model estimates MSD probabilities over 5, 10, and 15 years for the neck (0.537 ± 0.156), shoulder (0.449 ± 0.084), and elbows (0.277 ± 0.221). The model enables individual risk profiling, influenced by dynamic parameters that can reduce the long-term risk by up to 70.49%. The model is in its early development stages, i.e., it is the proof of concept that offers a new approach to assessing MSD risk at work using motion tracking data in combination with statistics. Further studies with larger sample sizes and validated criterion weights are needed to refine and validate this approach.