Optical imaging of single biomolecules and complexes in living cells provides a useful window into cellular processes. However, the three-dimensional dynamics of most important biomolecules in living cells remains essentially uncharacterized. The precise subcellular localization of mRNA-protein complexes plays a critical role in the spatial and temporal control of gene expression, and a full understanding of the control of gene expression requires precise characterization of mRNA transport dynamics beyond the optical diffraction limit. In this paper, we describe three-dimensional tracking of single mRNA particles with 25-nm precision in the x and y dimensions and 50-nm precision in the z dimension in live budding yeast cells using a microscope with a double-helix point spread function. Two statistical methods to detect intermittently confined and directed transport were used to quantify the three-dimensional trajectories of mRNA for the first time, using ARG3 mRNA as a model. Measurements and analysis show that the dynamics of ARG3 mRNA molecules are mostly diffusive, although periods of non-Brownian confinement and directed transport are observed. The quantitative methods detailed in this paper can be broadly applied to the study of mRNA localization and the dynamics of diverse other biomolecules in a wide variety of cell types.
We describe the corkscrew point spread function (PSF), which can localize objects in three dimensions throughout a depth of field with nanometer precision. The corkscrew PSF rotates as a function of the axial (z) position of an emitter. Fisher information calculations show that the corkscrew PSF can achieve nanometer localization precision with limited numbers of photons. We demonstrate three-dimensional super-resolution microscopy with the corkscrew PSF by imaging beads on the surface of a triangular polydimethylsiloxane (PDMS) grating. With 99,000 photons detected, the corkscrew PSF achieves a localization precision of in x, in y, and in z.
Wide-field microscopy with a double-helix point spread function (DH-PSF) provides three-dimensional (3D) position information beyond the optical diffraction limit. We compare the theoretical localization precision for an unbiased estimator of the DH-PSF to that for 3D localization by astigmatic and biplane imaging using Fisher information analysis including pixelation and varying levels of background. The DH-PSF results in almost constant localization precision in all three dimensions for a thick depth of field while astigmatism and biplane improve the axial localization precision over smaller axial ranges. For high signal-to-background ratio, the DH-PSF on average achieves better localization precision.
1 January 2010 in Multiscale Modeling & Simulation
First, we propose a new stochastic model for a spatially incoherent source in optical phenomena. The model naturally incorporates the incoherent property into the electromagnetic wave equation through a random source term. Then we propose a new numerical method based on Wiener chaos expansion (WCE) and apply it to solve the resulting stochastic wave equation. The main advantage of the WCE method is that it separates random and deterministic effects and allows the random effects to be factored out of the primary partial differential equation (PDE) very effectively. Therefore, the stochastic PDE is reduced to a set of deterministic PDEs for the coefficients of the WCE method which can be solved by conventional numerical algorithms. We solve these secondary deterministic PDEs by a finite-difference time domain (FDTD) method and demonstrate that the numerical computations based on the WCE method are considerably more efficient than the brute-force simulations. Moreover, the WCE approach does not require gener...
Designing a low-cost, compact, yet sensitive planar microwave sensor for complex permittivity measurement is highly desired for numerous applications though quite challenging. Here, in this research, an ultrasensitive planar microwave sensor is proposed which is based on an electric LC structure. The core sensor was fabricated on an FR-4 substrate using a simple fabrication process, then integrated within a polymethylmethacrylate microfluidic channel for straightforward liquid delivery to the sensing region. The resonance frequency of the bare sensor was designed to occur at 4.14 GHz while empty and shifted to 0.88 GHz when deionized water flows into the channel. The sensor response has been characterized for different mixture ratios of methanol and ethanol with deionized water. Next, the complex permittivity of the resulted binary mixtures has been extracted by the Debye model through a least square fitting method. The calculated average sensitivity is 1.45% which stands above most of sensors reported in the literature. Besides, the sensor has a small footprint with dimensions of 3.6 × 3.8 mm $$^2$$ making it a suitable candidate for integration with point-of-care testing devices.