High-k metal oxides are gradually replacing the traditional SiO2 dielectric layer in the new generation of electronic devices. In this paper, we report the production of five-element high entropy metal oxides (HEMOs) dielectric films by solution method and analyzed the role of each metal oxide in the system by characterizing the film properties. On this basis, we found optimal combination of (AlGaTiYZr)Ox with the best dielectric properties, exhibiting a low leakage current of 1.2 × 10−8 A/cm2 @1 MV/cm and a high dielectric constant, while the film’s visible transmittance is more than 90%. Based on the results of factor analysis, we increased the dielectric constant up to 52.74 by increasing the proportion of TiO2 in the HEMOs and maintained a large optical bandgap (>5 eV). We prepared thin film transistors (TFTs) based on an (AlGaTiYZr)Ox dielectric layer and an InGaZnOx (IGZO) active layer, and the devices exhibit a mobility of 18.2 cm2/Vs, a threshold voltage (Vth) of −0.203 V, and an subthreshold swing (SS) of 0.288 V/dec, along with a minimal hysteresis, which suggests a good prospect of applying HEMOs to TFTs. It can be seen that the HEMOs dielectric films prepared based on the solution method can combine the advantages of various high-k dielectrics to obtain better film properties. Moreover, HEMOs dielectric films have the advantages of simple processing, low-temperature preparation, and low cost, which are expected to be widely used as dielectric layers in new flexible, transparent, and high-performance electronic devices in the future.
Structural optimization of the cathode flow field is a viable approach to homogenize multi-physical field distributions and boost the output of air-cooled proton exchange membrane fuel cells (PEMFCs). This work develops a three-dimensional non-isothermal model to systematically evaluate the performance of graded flow channel designs. The results indicate that the graded structure promotes fluid transport in the central zone, thereby improving oxygen distribution uniformity at the gas diffusion layer/catalyst layer (GDL/CL) interface. Compared to the traditional parallel flow channel (with an average oxygen mass fraction of 0.051% and a uniformity index of 0.779), this configuration yields a 6.4% increase in the average oxygen mass fraction and a 0.96% enhancement in distribution uniformity. However, increased gradient flow reduces the flow velocity within the channels and raises the operating temperature, posing challenges for water and thermal management. The curved channel design, featuring longer channels at the ends and shorter channels in the center, compensates for the uneven air supply caused by the fan, thus balancing the flow distribution. Among the tested configurations, the 10° curved structure exhibits optimal performance, achieving the best compromise between gas distribution and liquid water removal. It effectively promotes oxygen diffusion and uniform water distribution, significantly alleviating mass transfer polarization and yielding a more uniform interface temperature distribution due to evaporative cooling. Both excessively small and large curvature angles lead to performance degradation, primarily due to inadequate water removal and flow separation, accompanied by excessive pressure drop, respectively. In contrast, the 10° curved channel strikes an optimal balance, offering significant advantages in overall cell performance and water–thermal management, which provides critical guidance for optimizing PEMFC flow field designs.
Air-cooled proton exchange membrane fuel cells (PEMFCs) are promising power sources for unmanned aerial vehicles because of their high specific energy and relatively simple balance-of-plant requirements. However, maintaining an acceptable and uniform stack temperature with low auxiliary power remains challenging. This study investigates a periodic edge-cooling configuration in which multiple fans are arranged at equal intervals along the long sides of a PEMFC stack. A three-dimensional steady conjugate heat-transfer model was developed to evaluate five heat fluxes, ranging from 2,400 to 3,600 W m −2 , and five fan spacings of 20–60 mm. For each of the 25 cases, the inlet velocity was iteratively adjusted until the maximum active-area temperature satisfied 358.15 ± 0.1 K. The effects of fan spacing and heat flux on the active-area temperature difference, airflow requirement, pressure drop, and representative-unit airflow hydraulic power were then analyzed. The results show that increasing heat flux requires a higher inlet velocity and increases both the pressure drop and temperature nonuniformity. As the fan spacing increases, the required airflow hydraulic power first decreases and then increases because of the competing effects of outlet-area enlargement, flow-path extension, and increased airflow demand. A second-order response-surface model fitted to the Computational Fluid Dynamics (CFD) results indicates a candidate low-airflow-power spacing region of approximately 38–40 mm over the investigated heat-flux range. This candidate spacing range is specific to the ideal periodic geometry and operating conditions investigated here. Because the full three-dimensional model has not been supported by a formal mesh-convergence study or independent experimental validation, the results should be interpreted as preliminary comparative design guidance rather than validated full-stack predictions.