Emine Yağız Gürbüz

Dr. Emine Yağız Gürbüz

Energy Systems Engineering, Muğla Sıtkı Koçman University, Muğla, Turkey (Türkiye)
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Renewable Energy
Verified
Journal Article
Closed access
Emine Yağız GürbüzEmine Yağız Gürbüz
Emine Yağız Gürbüz
OGOnur Vahip Güler
Onur Vahip Güler
AKAli Keçebaş
Ali Keçebaş

2 December 2023 in Energy
Verified
Journal Article
Closed access
ATAzim Doğuş Tuncer
Azim Doğuş Tuncer
Emine Yağız GürbüzEmine Yağız Gürbüz
Emine Yağız Gürbüz
IŞİsTemihan Şahinkesen
İsTemihan Şahinkesen
AGAleksandar Georgiev
Aleksandar Georgiev
AKAli Keçebaş
Ali Keçebaş

9 August 2023 in Renewable Energy
Verified
Journal Article
Closed access
Emine Yağız GürbüzEmine Yağız Gürbüz
Emine Yağız Gürbüz
IŞİsTemihan Şahinkesen
İsTemihan Şahinkesen
ATAzim Doğuş Tuncer
Azim Doğuş Tuncer
AKAli Keçebaş
Ali Keçebaş

1 May 2023 in Energy
Verified
Journal Article
Closed access
Emine Yağız GürbüzEmine Yağız Gürbüz
Emine Yağız Gürbüz
IŞİsTemihan Şahinkesen
İsTemihan Şahinkesen
BKBarış Kusun
Barış Kusun
ATAzim Doğuş Tuncer
Azim Doğuş Tuncer
AKAli Keçebaş
Ali Keçebaş

3 November 2020 in Experimental Heat Transfer
Verified
Journal Article
Closed access
Emine Yağız GürbüzEmine Yağız Gürbüz
Emine Yağız Gürbüz
Adnan SÖZENAdnan SÖZEN
Adnan SÖZEN
Ali KeçebaşAli Keçebaş
Ali Keçebaş
EÖEngin Özbaş
Engin Özbaş
In this paper, the effect of various zinc oxide aluminate spinel (ZnOAl2O3) and titanium oxide (TiO2) nanoparticle concentrations on the thermal performance of the Diffusion Absorption Refrigeration (DAR) system is investigated. The main aim of the study is to increase the efficiency of DAR systems operating with low thermal performance. The first part of the study is experimentally tested on the system under the same ambient conditions in order to develop passive heat transfer using different nanofluids as working liquids, including ammonia/water solution containing different amounts (1 wt.% and 2 wt.%) of ZnOAl2O3 and TiO2 particles. In the next part of the study, the tested system is designed in MATLAB/Simulink toolbox environment to compare experimental and numerical results. The use of nanofluids can increase the surface area expansion and the heat capacity of the fluid, resulting in a significant positive increase in heat transfer. The results clarify that the use of nanofluid as working fluid in the DAR system helps quicker evaporation, which reduces operating time and increases heat transfer in the generator. Compared to a base DAR system, the nanofluid solution with a 2 wt.% ZnOAl2O3 nanoparticle concentration among other nanofluid and proportions causes a 57% increase in the coefficient of performance (COP) of DAR system.

15 March 2021 in Heat and Mass Transfer
Verified
Journal Article
Closed access
PDF file
ASAdnan Sözen
Adnan Sözen
AKAli Keçebaş
Ali Keçebaş
Emine Yağız GürbüzEmine Yağız Gürbüz
Emine Yağız Gürbüz