Darko Boljevic

Dr. Darko Boljevic

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in Frontiers in Microbiology
Verified
Journal Article
Open access
PDF file
ANAleksandra Nikolić
Aleksandra Nikolić
DBDarko Boljevic
Darko Boljevic
MBMilovan Bojić
Milovan Bojić
SVStefan Veljković
Stefan Veljković
DVDragana Miroslav Vukovic
Dragana Miroslav Vukovic
SRSalvatore Rubino
Salvatore Rubino
Lyme endocarditis is extremely rare manifestation of Lyme disease. The clinical manifestations of Lyme endocarditis are non-specific and can be very challenging diagnosis to make when it is the only manifestation of the disease. Until now, only a few cases where reported. Physicians should keep in mind the possibility of borrelial etiology of endocarditis in endemic areas. Appropriate valve tissue sample should be sent for histopathology, culture, and PCR especially in case of endocarditis of unknown origin PCR on heart valve samples is recommended. With more frequent PCR, Borrelia spp. may be increasingly found as a cause of infective endocarditis. Prompt diagnosis and treatment of Lyme carditis may prevent surgical treatment and pacemaker implantations. Due to climate change and global warming Lyme disease is a growing problem. Rising number of Lyme disease cases we can expect and rising number of Lyme endocarditis.

28 February 2020 in Blood Purification
Verified
Journal Article
Closed access
PDF file
DBDarko Boljevic
Darko Boljevic
ANAleksandra Nikolic
Aleksandra Nikolic
SRSinisa Rusovic
Sinisa Rusovic
JLJovana Lakcevic
Jovana Lakcevic
MBMilovan Bojic
Milovan Bojic
BBBela Balint
Bela Balint
Background: In patients with ST-elevation myocardial infarction (STEMI), C-reactive protein (CRP) levels are associated with larger infarct size, transmural extent, and poor function of left ventricle and independently predict 30-day mortality. CRP-apheresis following STEMI showed to be feasible, safe, and has significant beneficial effect both on myocardial infarction size and wall motion. To the best of our knowledge, this is only the second published clinical evaluation of the efficacy and safety of selective CRP-apheresis in the STEMI treatment using Spectra-Optia and Pentrasorb CRP-adsorber systems. Case Report: A 53-year-old female was referred with anterior STEMI. After percutaneous coronary intervention, patient received standard post-STEMI therapy according to current guidelines. Selective therapeutic plasma exchange (TPE) was performed using Spectra-Optia (Terumo BCT; USA) and Pentrasorb CRP-adsorber (Pentracor GmbH; Germany) systems. Antecubital veins were used for vascular access and acid-citrate-dextrose solution (ACD formula A; total volume = 1,026 mL) was utilized as anticoagulant. The volume of processed blood was 15,600 mL. The removed “natural” plasma (total volume = 8,329 mL) was replaced with CRP-depleted autologous plasma (total volume = 8,085 mL). This intensive TPE-treatment was well tolerated, without adverse effects, or complications. The CRP plasma levels were: initial = 4.2 mg/L 6 h after acute myocardial infarction (AMI), pre-apheresis = 16.4 mg/L, and post-apheresis = 4.59 mg/L (CRP-depletion = 72%). There were neither significant changes observed in biochemistry nor any alterations in plasma hemostatic activity investigated before and after CRP-adsorption performed. Conclusion: Early performed CRP-apheresis is a promising innovative therapeutic approach for STEMI treatment that could provide a reduced size of infarction zone – with inferior occurrence of heart failure after AMI. However, precise and complete evaluation of the efficacy and safety of this treatment requires further multicenter randomized and larger clinical studies.

28 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MBMIlos Babic
MIlos Babic
SVStefan Veljković
Stefan Veljković
JLJovana Lakčević
Jovana Lakčević
RBRade M. Babić
Rade M. Babić
MOMiodrag Ostojic
Miodrag Ostojic
ANAleksandra Nikolic
Aleksandra Nikolic
The 12-lead electrocardiogram (ECG) is a first-line diagnostic tool for patients with cardiac symptoms. As observed during the COVID-19 pandemic, the ECG is essential to the initial patient evaluation. The novel KardioPal three-lead-based ECG reconstructive technology provides a potential alternative to a standard ECG, reducing the response time and cost of treatment and improving patient comfort. Our study aimed to evaluate the diagnostic accuracy of a reconstructed 12-lead ECG obtained by the KardioPal technology, comparing it with the standard 12-lead ECG, and to assess the feasibility and time required to obtain a reconstructed ECG in a real-life scenario. A prospective, nonrandomized, single-center, adjudicator-blinded trial was conducted on 102 patients during the COVID-19 pandemic at the Dedinje Cardiovascular Institute in Belgrade. The KardioPal system demonstrated a high feasibility rate (99%), with high specificity (96.3%), sensitivity (95.8%), and diagnostic accuracy (96.1%) for obtaining clinically relevant matching of reconstructed 12-lead compared to the standard 12-lead ECG recording. This novel technology provided a significant reduction in ECG acquisition time and the need for personnel and space for obtaining ECG recordings, thereby reducing the risk of viral transmission and the burden on an already overwhelmed healthcare system such as the one experienced during the COVID-19 pandemic.

30 November 2019 in The Journal of Infection in Developing Countries
Verified
Journal Article
Open access
PDF file
DBDarko Boljevic
Darko Boljevic
Aleksandra BaracAleksandra Barac
Aleksandra Barac
PVPetar Vukovic
Petar Vukovic
DKDejan Kojic
Dejan Kojic
MBMilovan Bojic
Milovan Bojic
ANAleksandra Nikolic
Aleksandra Nikolic
Background: Cardiac device-related endocarditis has emerged as a serious complication in the era of advanced medical technology. Pacemaker related infections are rare and life-threatening with incidence from 0.06% to 7% and high mortality rate (30-35%). Diagnosis is hard, frequently delayed and could be even missed due to poor clinical findings. The average delay in diagnosis is 5.5 month. We report a case of the late-onset of pacemaker lead endocarditis caused by S. epidermidis successfully treated with open heart surgery. Case Report: Patient with persistent high fever for 11 month and suspicion for infective endocarditis was admitted in Cardiovascular Institute. No clinical signs of endocarditis were observed. TTE revealed large vegetation 30 × 17 mm attached to the atrial electrodes with high embolic potential. This finding was verified by transesophageal echocardiography (TEE), although CT scan did not reveal vegetation. Blood cultures were negative. A sternotomy with cardiopulmonary bypass was performed and electrodes were extracted with large vegetation. Intraoperative finding revealed large thrombus with vegetation around pacemaker leads. Cultures of the electrodes and vegetation revealed Staphylococcus epidermidis. Surgery was followed up with antibiotic treatment for 6 weeks. He has been followed up for the next 2 years, and without complications. Conclusion: The absence of criteria for endocarditis and negative blood cultures should not keep the physician from ruling out lead endocarditis. This complication carries high risk of mortality if left untreated.

3 November 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
DBDarko Boljevic
Darko Boljevic
JLJovana Lakčević
Jovana Lakčević
MFMihajlo Farkić
Mihajlo Farkić
VMVladimir Mihajlovic Mihajlovic
Vladimir Mihajlovic Mihajlovic
SVStefan Veljković
Stefan Veljković
ANAleksandra Nikolic
Aleksandra Nikolic
Background and Clinical Significance: Concomitant severe aortic stenosis (AS) and abdominal aortic aneurysm (AAA) in elderly patients presents a significant therapeutic challenge. While transcatheter aortic valve replacement (TAVR) and endovascular aneurysm repair (EVAR) have become established minimally invasive treatments for high-risk patients, simultaneous management of both conditions remains rare. Case Presentation: We report the first documented case in Serbia of a simultaneous TAVR and EVAR in a 75-year-old male with severe symptomatic AS and AAA. The patient had a history of hypertension, diabetes mellitus, atrial fibrillation, prior radiofrequency pulmonary vein ablation, and pacemaker implantation. Echocardiography demonstrated severe AS with a transvalvular gradient of 116/61 mmHg, an aortic valve area of 0.6 cm2, and a left ventricular ejection fraction of 30–35%. Coronary angiography revealed 50–60% stenosis of the right coronary artery. Following evaluation by a multidisciplinary Heart and Vascular Team, a combined procedure was performed under general anesthesia via bilateral femoral access. TAVR with a Medtronic Evolut R valve was successfully deployed, followed by EVAR with satisfactory stent graft positioning and angiographic results. The patient’s postoperative course was uneventful, and he was discharged on the ninth day. At six-month follow-up, echocardiography showed optimal valve function, and CT identified a type II endoleak, which was managed conservatively. Conclusions: This case demonstrates the feasibility and safety of simultaneous TAVR and EVAR in a high-risk elderly patient, emphasizing the importance of careful preoperative planning and a coordinated multidisciplinary approach. Further studies are warranted to establish standardized guidelines for the management of patients with coexisting severe AS and AAA.

24 May 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
DBDarko Boljevic
Darko Boljevic
MBMilovan Bojic
Milovan Bojic
MFMihajlo Farkic
Mihajlo Farkic
DSDragan Sagic
Dragan Sagic
DTDragan Topic
Dragan Topic
ANAleksandra Nikolic
Aleksandra Nikolic
Introduction: Severe aortic stenosis, a highly-common valve disease in the elderly, has a poor prognosis if left untreated. To address the concern of effective procedures for severe aortic stenosis, a systematic TAVI program was established at the Dedinje Cardiovascular Institute (Belgrade, Serbia). Methods: Our cohort was composed of 56 patients (74±15 years old). The mean logistic EuroScore was 10.17%; the mean Society of Thoracic Surgeons score was 3.22%. One third of the patients were categorized as class III or IV of the New York Heart Association (NYHA). The valves selected for use were either self-expandable or balloon expandable (Evolut R, Medtronic; Acurate Neo, Boston Scientific and Myval, Meril). The choice of valve type was made by the Institute's Structural Heart Team, in accordance with the patient's native aortic valve, size and calcification of ilio-femoral vessels, as well as the need for alternative access. TAVI procedure was conducted according to current guidelines provided by the European Society of Cardiology. Results: The procedure success rate was 100%. Trans-femoral approach was achieved in 100% of patients; percutaneously in 87.5%, while a surgical cut was necessary in 12.5%. No patient showed moderate or severe aortic regurgitation after the procedure, although trace or mild regurgitation was recorded in 30.3%. Permanent pacemaker was implanted in one patient (1.78%), contrast induced acute kidney injury occured in one patient (1.78%), no stroke was recorded, and three pseudo-aneurysms which required surgical intervention occurred. Three patients required blood transfusions (5.33%). A 30-day all-cause mortality rate was 1.78%. Conclusion: The Dedinje Cardiovascular Institute spearheaded all efforts to establish a TAVI program in Serbia. Our initial TAVI results are promising, encouraging, and comparable with the results of previous large randomized trials. This initial experience opens the door for further development with a goal of our Institute to become a high-volume TAVI center.