Mobility impairment is common in people with multiple sclerosis (PwMS) and there is a need to assess mobility in remote settings. Here, we apply a novel wireless, skin-mounted, and conformal inertial sensor (BioStampRC, MC10 Inc.) to examine gait characteristics of PwMS under controlled conditions. We determine the accuracy and precision of BioStampRC in measuring gait kinematics by comparing to contemporary research-grade measurement devices. A total of 45 PwMS, who presented with diverse walking impairment (Mild MS = 15, Moderate MS = 15, Severe MS = 15), and 15 healthy control subjects participated in the study. Participants completed a series of clinical walking tests. During the tests participants were instrumented with BioStampRC and MTx (Xsens, Inc.) sensors on their shanks, as well as an activity monitor GT3X (Actigraph, Inc.) on their non-dominant hip. Shank angular velocity was simultaneously measured with the inertial sensors. Step number and temporal gait parameters were calculated from the data recorded by each sensor. Visual inspection and the MTx served as the reference standards for computing the step number and temporal parameters, respectively. Accuracy (error) and precision (variance of error) was assessed based on absolute and relative metrics. Temporal parameters were compared across groups using ANOVA. Mean accuracy±precision for the BioStampRC was 2±2 steps error for step number, 6±9ms error for stride time and 6±7ms error for step time (0.6–2.6% relative error). Swing time had the least accuracy±precision (25±19ms error, 5±4% relative error) among the parameters. GT3X had the least accuracy±precision (8±14% relative error) in step number estimate among the devices. Both MTx and BioStampRC detected significantly distinct gait characteristics between PwMS with different disability levels (p<0.01). BioStampRC sensors accurately and precisely measure gait parameters in PwMS across diverse walking impairment levels and detected differences in gait characteristics by disability level in PwMS. This technology has the potential to provide granular monitoring of gait both inside and outside the clinic.
Gait speed is a powerful clinical marker for mobility impairment in patients suffering from neurological disorders. However, assessment of gait speed in coordination with delivery of comprehensive care is usually constrained to clinical environments and is often limited due to mounting demands on the availability of trained clinical staff. These limitations in assessment design could give rise to poor ecological validity and limited ability to tailor interventions to individual patients. Recent advances in wearable sensor technologies have fostered the development of new methods for monitoring parameters that characterize mobility impairment, such as gait speed, outside the clinic, and therefore address many of the limitations associated with clinical assessments. However, these methods are often validated using normal gait patterns; and extending their utility to subjects with gait impairments continues to be a challenge. In this paper, we present a machine learning method for estimating gait speed using a configurable array of skin-mounted, conformal accelerometers. We establish the accuracy of this technique on treadmill walking data from subjects with normal gait patterns and subjects with multiple sclerosis-induced gait impairments. For subjects with normal gait, the best performing model systematically overestimates speed by only 0.01 m/s, detects changes in speed to within less than 1%, and achieves a root-mean-square-error of 0.12 m/s. Extending these models trained on normal gait to subjects with gait impairments yields only minor changes in model performance. For example, for subjects with gait impairments, the best performing model systematically overestimates speed by 0.01 m/s, quantifies changes in speed to within 1%, and achieves a root-mean-square-error of 0.14 m/s. Additional analyses demonstrate that there is no correlation between gait speed estimation error and impairment severity, and that the estimated speeds maintain the clinical significance of ground truth speed in this population. These results support the use of wearable accelerometer arrays for estimating walking speed in normal subjects and their extension to MS patient cohorts with gait impairment.
Inertial measurement units (IMUs) are increasingly utilized as motion capture devices in human movement studies. Given their high portability, IMUs can be deployed in any environment, importantly those outside of the laboratory. However, a significant challenge limits the adoption of this technology; namely estimating the orientation of the IMUs to a common world frame, which is essential to estimating the rotations across skeletal joints. Common (probabilistic) methods for estimating IMU orientation rely on the ability to update the current orientation estimate using data provided by the IMU. The objective of this work is to present a novel error-state Kalman filter that yields highly accurate estimates of IMU orientation that are robust to poor measurement updates from fluctuations in the local magnetic field and/or highly dynamic movements. The method is validated with ground truth data collected with highly accurate orientation measurements provided by a coordinate measurement machine. As an example, the method yields IMU-estimated orientations that remain within 3.7 degrees (RMS error) over relatively long (25 cumulative minutes) trials even in the presence of large fluctuations in the local magnetic field. For comparison, ignoring the magnetic interference increases the RMS error to 12.8 degrees, more than a threefold increase.
Wearable sensors have the potential to enable comprehensive patient characterization and optimized clinical intervention. Critical to realizing this vision is accurate estimation of biomechanical time-series in daily-life, including joint, segment, and muscle kinetics and kinematics, from wearable sensor data. The use of physical models for estimation of these quantities often requires many wearable devices making practical implementation more difficult. However, regression techniques may provide a viable alternative by allowing the use of a reduced number of sensors for estimating biomechanical time-series. Herein, we review 46 articles that used regression algorithms to estimate joint, segment, and muscle kinematics and kinetics. We present a high-level comparison of the many different techniques identified and discuss the implications of our findings concerning practical implementation and further improving estimation accuracy. In particular, we found that several studies report the incorporation of domain knowledge often yielded superior performance. Further, most models were trained on small datasets in which case nonparametric regression often performed best. No models were open-sourced, and most were subject-specific and not validated on impaired populations. Future research should focus on developing open-source algorithms using complementary physics-based and machine learning techniques that are validated in clinically impaired populations. This approach may further improve estimation performance and reduce barriers to clinical adoption.
11 May 2021 in IEEE Journal of Biomedical and Health Informatics
Falls are a significant problem for persons with multiple sclerosis (PwMS). Yet fall prevention interventions are not often prescribed until after a fall has been reported to a healthcare provider. While still nascent, objective fall risk assessments could help in prescribing preventative interventions. To this end, retrospective fall status classification commonly serves as an intermediate step in developing prospective fall risk assessments. Previous research has identified measures of gait biomechanics that differ between PwMS who have fallen and those who have not, but these biomechanical indices have not yet been leveraged to detect PwMS who have fallen. Moreover, they require the use of laboratory-based measurement technologies, which prevent clinical deployment. Here we demonstrate that a bidirectional long short-term (BiLSTM) memory deep neural network was able to identify PwMS who have recently fallen with good performance (AUC of 0.88) based on accelerometer data recorded from two wearable sensors during a one-minute walking task. These results provide substantial improvements over machine learning models trained on spatiotemporal gait parameters (21% improvement in AUC), statistical features from the wearable sensor data (16%), and patient-reported (19%) and neurologist-administered (24%) measures in this sample. The success and simplicity (two wearable sensors, only one-minute of walking) of this approach indicates the promise of inexpensive wearable sensors for capturing fall risk in PwMS.
There is a critical need for fast, inexpensive, objective, and accurate screening tools for childhood psychopathology. Perhaps most compelling is in the case of internalizing disorders, like anxiety and depression, where unobservable symptoms cause children to go unassessed–suffering in silence because they never exhibiting the disruptive behaviors that would lead to a referral for diagnostic assessment. If left untreated these disorders are associated with long-term negative outcomes including substance abuse and increased risk for suicide. This paper presents a new approach for identifying children with internalizing disorders using an instrumented 90-second mood induction task. Participant motion during the task is monitored using a commercially available wearable sensor. We show that machine learning can be used to differentiate children with an internalizing diagnosis from controls with 81% accuracy (67% sensitivity, 88% specificity). We provide a detailed description of the modeling methodology used to arrive at these results and explore further the predictive ability of each temporal phase of the mood induction task. Kinematical measures most discriminative of internalizing diagnosis are analyzed in detail, showing affected children exhibit significantly more avoidance of ambiguous threat. Performance of the proposed approach is compared to clinical thresholds on parent-reported child symptoms which differentiate children with an internalizing diagnosis from controls with slightly lower accuracy (.68-.75 vs. .81), slightly higher specificity (.88–1.00 vs. .88), and lower sensitivity (.00-.42 vs. .67) than the proposed, instrumented method. These results point toward the future use of this approach for screening children for internalizing disorders so that interventions can be deployed when they have the highest chance for long-term success.