Yuanyuan Jia

Prof. Dr. Yuanyuan Jia


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YJYuanyuan Jia
Yuanyuan Jia
AGAli Gholipour
Ali Gholipour
ZHZhongshi He
Zhongshi He
SWSimon K. Warfield
Simon K. Warfield
In magnetic resonance (MR), hardware limitations, scan time constraints, and patient movement often result in the acquisition of anisotropic 3-D MR images with limited spatial resolution in the out-of-plane views. Our goal is to construct an isotropic high-resolution (HR) 3-D MR image through upsampling and fusion of orthogonal anisotropic input scans. We propose a multiframe super-resolution (SR) reconstruction technique based on sparse representation of MR images. Our proposed algorithm exploits the correspondence between the HR slices and the low-resolution (LR) sections of the orthogonal input scans as well as the self-similarity of each input scan to train pairs of overcomplete dictionaries that are used in a sparse-land local model to upsample the input scans. The upsampled images are then combined using wavelet fusion and error backprojection to reconstruct an image. Features are learned from the data and no extra training set is needed. Qualitative and quantitative analyses were conducted to evaluate the proposed algorithm using simulated and clinical MR scans. Experimental results show that the proposed algorithm achieves promising results in terms of peak signal-to-noise ratio, structural similarity image index, intensity profiles, and visualization of small structures obscured in the LR imaging process due to partial volume effects. Our novel SR algorithm outperforms the nonlocal means (NLM) method using self-similarity, NLM method using self-similarity and image prior, self-training dictionary learning-based SR method, averaging of upsampled scans, and the wavelet fusion method. Our SR algorithm can reduce through-plane partial volume artifact by combining multiple orthogonal MR scans, and thus can potentially improve medical image analysis, research, and clinical diagnosis.

1 July 2021 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
BHBaoru HAN
Baoru HAN
JDJinglong Du
Jinglong Du
YJYuanyuan Jia
Yuanyuan Jia
HZHuazheng Zhu
Huazheng Zhu
Aiming at the security issues in the storage and transmission of medical images in the medical information system, combined with the special requirements of medical images for the protection of lesion areas, this paper proposes a robust zero-watermarking algorithm for medical images’ security based on VGG19. First, the pretrained VGG19 is used to extract deep feature maps of medical images, which are fused into the feature image. Second, the feature image is transformed by Fourier transform, and low-frequency coefficients of the Fourier transform are selected to construct the feature matrix of the medical image. Then, based on the low-frequency part of the feature matrix of the medical image, the mean-perceptual hashing algorithm is used to achieve a set of 64-bit binary perceptual hashing values, which can effectively resist local nonlinear geometric attacks. Finally, the algorithm adopts a watermarking image after scrambling and the 64-bit binary perceptual hashing value to obtain robust zero-watermarking. At the same time, the proposed algorithm utilizes Hermite chaotic neural network to scramble the watermarking image for secondary protection, which enhances the security of the algorithm. Compared with the existing related works, the proposed algorithm is simple to implement and can effectively resist local nonlinear geometric attacks, with good robustness, security, and invisibility.

20 August 2015 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YJYuanyuan Jia
Yuanyuan Jia
ZHZhongshi He
Zhongshi He
AGAli Gholipour
Ali Gholipour
SWSimon K. Warfield
Simon K. Warfield
In magnetic resonance (MR), hardware limitation, scanning time, and patient comfort often result in the acquisition of anisotropic 3-D MR images. Enhancing image resolution is desired but has been very challenging in medical image processing. Super resolution reconstruction based on sparse representation and overcomplete dictionary has been lately employed to address this problem; however, these methods require extra training sets, which may not be always available. This paper proposes a novel single anisotropic 3-D MR image upsampling method via sparse representation and overcomplete dictionary that is trained from in-plane high resolution slices to upsample in the out-of-plane dimensions. The proposed method, therefore, does not require extra training sets. Abundant experiments, conducted on simulated and clinical brain MR images, show that the proposed method is more accurate than classical interpolation. When compared to a recent upsampling method based on the nonlocal means approach, the proposed method did not show improved results at low upsampling factors with simulated images, but generated comparable results with much better computational efficiency in clinical cases. Therefore, the proposed approach can be efficiently implemented and routinely used to upsample MR images in the out-of-planes views for radiologic assessment and postacquisition processing.

26 April 2023 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
CMChenyang Ma
Chenyang Ma
YQYonggang Qian
Yonggang Qian
KLKun Li
Kun Li
XDXianhui Dou
Xianhui Dou
Huanfeng ShenHuanfeng Shen
Huanfeng Shen
GOGuangzhou Ou-Yang
Guangzhou Ou-Yang
The separation of land surface temperature (LST) and land surface emissivity (LSE) is an ill-posed problem in thermal infrared (TIR) remote sensing. By building a new observation matrix to compress the LSE unknows and a dictionary training method to reconstruct complete LSE spectra, a new dictionary-based sparse representation for emissivity (DSRE) method has been proposed to retrieve LST and LSE from the atmospherically corrected hyperspectral TIR data. The proposed method fully utilizes the sparsity of compressed sensing and the empirical knowledge of the trained emissivity dictionary. The sensitivity analysis shows that the modeling accuracies of the proposed method are 0.215 K and 0.0060 for LST and LSE, respectively. Even with the instrument noise of 0.3 K and the uncertainties in atmospheric transmittance, atmospheric upwelling, and downwelling radiance of 10 %, the retrieval accuracies are 0.811 K for LST and 0.0241 for LSE, respectively. Then a field experiment was conducted to validate the proposed method, and a comparison was executed to three published methods, including ASTER temperature-emissivity separation (ASTERTES), linear spectral emissivity constraint TES (LSECTES), and iterative spectrally smooth TES (ISSTES). The accuracies of retrieved LST and spectral LSE are 1.41 K / 0.009, 2.57 K / 0.071, 1.59 K / 0.038, and 2.00 K / 0.077 for DSRE, ASTERTES, LSECTES, and ISSTES. In contrast to the three published methods, our proposed method is more accurate and effective than other published methods. Especially in the atmospheric absorption band, the proposed method has a strong anti-noise capability to the residuals of environmental downwelling radiance.

1 October 2021 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
LWLulu Wang
Lulu Wang
JDJinglong Du
Jinglong Du
AGAli Gholipour
Ali Gholipour
HZHuazheng Zhu
Huazheng Zhu
ZHZhongshi He
Zhongshi He
YJYuanyuan Jia
Yuanyuan Jia

27 October 2015 in International Journal of Machine Learning and Cybernetics
Verified
Journal Article
Closed access
PDF file
HZHuazheng Zhu
Huazheng Zhu
ZHZhongshi He
Zhongshi He
YJYuanyuan Jia
Yuanyuan Jia