Zhixing Wang

Dr. Zhixing Wang

Radiation Oncology, City of Hope, Duarte, California, USA
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
XCXiaozhi Cao
Xiaozhi Cao
CLCongyu Liao
Congyu Liao
ZWZhixing Wang
Zhixing Wang
YCYing Chen
Ying Chen
HYHuihui Ye
Huihui Ye
JZJianhui Zhong
Jianhui Zhong

24 February 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
XCXiaozhi Cao
Xiaozhi Cao
CLCongyu Liao
Congyu Liao
SISiddharth Srinivasan Iyer
Siddharth Srinivasan Iyer
ZWZhixing Wang
Zhixing Wang
ZZZihan Zhou
Zihan Zhou
KSKawin Setsompop
Kawin Setsompop

1 November 2001 in Brain and Development
Verified
Journal Article
Closed access
ZZZhongshu Zhou
Zhongshu Zhou
WYWeiming Yu
Weiming Yu
YFYukio Fukuyama
Yukio Fukuyama
CZCheng-(L)Ning Zheng
Cheng-(L)Ning Zheng
ZWZhixing Wang
Zhixing Wang

11 November 2024 in NMR in Biomedicine
Verified
Journal Article
Open access
QDQuan Dou
Quan Dou
ZWZhixing Wang
Zhixing Wang
XFXue Feng
Xue Feng
ACAdrienne E. Campbell‐Washburn
Adrienne E. Campbell‐Washburn
JMJohn P. Mugler
John P. Mugler
CMCraig H. Meyer
Craig H. Meyer
MR images with high signal‐to‐noise ratio (SNR) provide more diagnostic information. Various methods for MRI denoising have been developed, but the majority of them operate on the magnitude image and neglect the phase information. Therefore, the goal of this work is to design and implement a complex‐valued convolutional neural network (CNN) for MRI denoising. A complex‐valued CNN incorporating the noise level map (non‐blind DnCNN) was trained with ground truth and simulated noise‐corrupted image pairs. The proposed method was validated using both simulated and in vivo data collected from low‐field scanners. Its denoising performance was quantitively and qualitatively evaluated, and it was compared with the real‐valued CNN and several other algorithms. For the simulated noise‐corrupted testing dataset, the complex‐valued models had superior normalized root‐mean‐square error, peak SNR, structural similarity index, and phase ABSD. By incorporating the noise level map, the non‐blind DnCNN showed better performance in dealing with spatially varying parallel imaging noise. For in vivo low‐field data, the non‐blind DnCNN significantly improved the SNR and visual quality of the image. The proposed non‐blind DnCNN provides an efficient and effective approach for MRI denoising. This is the first application of non‐blind DnCNN to medical imaging. The method holds the potential to enable improved low‐field MRI, facilitating enhanced diagnostic imaging in under‐resourced areas.

10 April 2023 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ZWZhixing Wang
Zhixing Wang
RRRajiv Ramasawmy
Rajiv Ramasawmy
XFXue Feng
Xue Feng
ACAdrienne E. Campbell‐Washburn
Adrienne E. Campbell‐Washburn
JMJohn P. Mugler
John P. Mugler
CMCraig H. Meyer
Craig H. Meyer
Purpose: To develop 2D turbo spin‐echo (TSE) imaging using annular spiral rings (abbreviated “SPRING‐RIO TSE”) with compensation of concomitant gradient fields and B0 inhomogeneity at both 0.55T and 1.5T for fast T2‐weighted imaging.Methods: Strategies of gradient waveform modifications were implemented in SPRING‐RIO TSE for compensation of self‐squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction‐based corrections to simultaneously compensate for the residual concomitant gradient and B0 field induced phase accruals along the readout. The signal pathway disturbance caused by time‐varying and spatially dependent concomitant fields was simulated, and echo‐to‐echo phase variations before and after sequence‐based compensation were compared. Images from SPRING‐RIO TSE with no compensation, with compensation, and Cartesian TSE were also compared via phantom and in vivo acquisitions.Results: Simulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off‐resonance corrections. Volunteer data showed that after full correction, the SPRING‐RIO TSE sequence achieved high image quality with improved SNR efficiency (15%–20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low‐field (0.55T).Conclusion: Implementation of SPRING‐RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time‐varying along the echo train and temporally asymmetric in TSE‐based imaging.

25 May 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
KQKun Qing
Kun Qing
TATalissa A. Altes
Talissa A. Altes
JMJohn P. Mugler
John P. Mugler
Jaime MataJaime Mata
Jaime Mata
NTNicholas Tustison
Nicholas Tustison
BMBorna Mehrad
Borna Mehrad
Purpose: The existing tools to quantify lung function in interstitial lung diseases have significant limitations. Lung MRI imaging using inhaled hyperpolarized xenon-129 gas (129Xe) as a contrast agent is a new technology for measuring regional lung physiology. We sought to assess the utility of the 129Xe MRI in detecting impaired lung physiology in usual interstitial pneumonia (UIP). Materials and methods: After institutional review board approval and informed consent and in compliance with HIPAA regulations, we performed chest CT, pulmonary function tests (PFTs), and 129Xe MRI in 10 UIP subjects and 10 healthy controls. Results: The 129Xe MRI detected highly heterogeneous abnormalities within individual UIP subjects as compared to controls. Subjects with UIP had markedly impaired ventilation (ventilation defect fraction: UIP: 30 ± 9%; healthy: 21 ± 9%; p = 0.026), a greater amount of 129Xe dissolved in the lung interstitium (tissue-to-gas ratio: UIP: 1.45 ± 0.35%; healthy: 1.10 ± 0.17%; p = 0.014), and impaired 129Xe diffusion into the blood (RBC-to-tissue ratio: UIP: 0.20 ± 0.06; healthy: 0.28 ± 0.05; p = 0.004). Most MRI variables had no correlation with the CT and PFT measurements. The elevated level of 129Xe dissolved in the lung interstitium, in particular, was detectable even in subjects with normal or mildly impaired PFTs, suggesting that this measurement may represent a new method for detecting early fibrosis. Conclusion: The hyperpolarized 129Xe MRI was highly sensitive to regional functional changes in subjects with UIP and may represent a new tool for understanding the pathophysiology, monitoring the progression, and assessing the effectiveness of treatment in UIP.