Djelloul Belkacemi

Dr. Djelloul Belkacemi

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
DBDjelloul Belkacemi
Djelloul Belkacemi
TMTAHAR ABBES Miloud
TAHAR ABBES Miloud
MAMohammed Al-Rawi
Mohammed Al-Rawi
AAAhmed Al_Jumaily
Ahmed Al_Jumaily
SBSofiane Bachene
Sofiane Bachene
BLBoualem Laribi
Boualem Laribi
Abdominal aortic aneurysms (AAA) continue to pose a high mortality risk despite advances in medical imaging and surgery. Intraluminal thrombus (ILT) is detected in most AAAs and may critically impact their development. Therefore, understanding ILT deposition and growth is of practical importance. To assist in managing these patients, the scientific community has been researching the relationship between intraluminal thrombus (ILT) and hemodynamic parameters wall shear stress (WSS) derivatives. This study analyzed three patient-specific AAA models reconstructed from CT scans using computational fluid dynamics (CFD) simulations and a pulsatile non-Newtonian blood flow model. The co-localization and relationship between WSS-based hemodynamic parameters and ILT deposition were examined. The results show that ILT tends to occur in regions of low velocity and time-averaged WSS (TAWSS) and high oscillation shear index (OSI), endothelial cell activation potential (ECAP), and relative residence time (RRT) values. ILT deposition areas were found in regions of low TAWSS and high OSI independently of the nature of flow near the wall characterized by transversal WSS (TransWSS). A new approach is suggested which is based on the estimation of CFD-based WSS indices specifically in the thinnest and thickest ILT areas of AAA patients; this approach is promising and supports the effectiveness of CFD as a decision-making tool for clinicians. Further research with a larger patient cohort and follow-up data are needed to confirm these findings.

24 October 2024 in Energy and Buildings
Verified
Journal Article
Closed access
MKM. Kassim
M. Kassim
MMM. Merzouk
M. Merzouk
NMN. Kasbadji Merzouk
N. Kasbadji Merzouk
LML. Merabti
L. Merabti
WTW. Taane
W. Taane
DBDjelloul Belkacemi
Djelloul Belkacemi

12 September 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
AAAhmed Al_Jumaily
Ahmed Al_Jumaily
MAMohammed Al-Rawi
Mohammed Al-Rawi
DBDjelloul Belkacemi
Djelloul Belkacemi
RSRadu Andy Sascau
Radu Andy Sascau
CRISTIAN STATESCUCRISTIAN STATESCU
CRISTIAN STATESCU
Larisa AnghelLarisa Anghel
Larisa Anghel
Cardiovascular diseases (CVD) remain the leading cause of mortality among older adults. Early detection is critical as the prognosis for advanced-stage CVD is often poor. Consequently, non-invasive diagnostic tools that can assess hemodynamic function, particularly of the aorta, are essential. Computational fluid dynamics (CFD) has emerged as a promising method for simulating cardiovascular dynamics efficiently and cost-effectively, using increasingly accessible computational resources. This study developed a CFD model to assess the aorta geometry using tetrahedral and polyhedral meshes. A healthy aorta was modeled with mesh sizes ranging from 0.2 to 1 mm. Key hemodynamic parameters, including blood pressure waveform, pressure difference, wall shear stress (WSS), and associated wall parameters like relative residence time (RRT), oscillatory shear index (OSI), and endothelial cell activation potential (ECAP) were evaluated. The performance of the CFD simulations, focusing on accuracy and processing time, was assessed to determine clinical viability. The CFD model demonstrated clinically acceptable results, achieving over 95% accuracy while reducing simulation time by up to 54%. The entire simulation process, from image construction to the post-processing of results, was completed in under 120 min. Both mesh types (tetrahedral and polyhedral) provided reliable outputs for hemodynamic analysis. This study provides a novel demonstration of the impact of mesh type in obtaining accurate hemodynamic data, quickly and efficiently, using CFD simulations for non-invasive aortic assessments. The method is particularly beneficial for routine check-ups, offering improved diagnostics for populations with limited healthcare access or higher cardiovascular disease risk.

1 September 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
MAMohammed Al-Rawi
Mohammed Al-Rawi
DBDjelloul Belkacemi
Djelloul Belkacemi
ELEric T.A. Lim
Eric T.A. Lim
MKManar Khashram
Manar Khashram
Aortic dissection is a catastrophic failure of the endothelial wall that could lead to malperfusion or rupture. Computational modelling tools may help detect arterial damage. Technological advancements have led to more sophisticated forms of modelling being made available to low-grade computers. These devices can create 3D models with clinical data, where the clinical blood pressure waveforms’ model can be used to form boundary conditions for assessing hemodynamic parameters, modelling blood flow propagation along the aorta to predict the development of cardiovascular disease. This study presents patient-specific data for a rare case of severe Type A aortic dissection. CT scan images were taken nine months apart, consisting of the artery both before and after dissection. The results for the pre-dissection CT showed that the pressure waveform at the ascending aorta was higher, and the systolic pressure was lagging at the descending aorta. For the post-dissection analysis, we observed the same outcome; however, the amplitude for the waveform (systolic pressure) at the ascending aorta increased in the false lumen by 25% compared to the true lumen by 3%. Also, the waveform peak (systolic) was leading by 0.01 s. The hemodynamic parameter of wall shear stress (WSS) predicted the aneurysm’s existence at the ascending aorta, as well as potential aortic dissection. The high WSS contours were located at the tear location at the peak blood flow of 0.14 s, which shows the potential of this tool for earlier diagnosis of aortic dissection.

30 September 2024 in Journal of Engineering and Science in Medical Diagnostics and Therapy
Verified
Journal Article
Open access
PDF file
MAMohammed Al-Rawi
Mohammed Al-Rawi
DBDjelloul Belkacemi
Djelloul Belkacemi
AAAhmed Al_Jumaily
Ahmed Al_Jumaily
Early diagnosis of cardiovascular diseases (CVDs), including arterial stenosis, enables targeted treatments that reduce CVD mortality. It is vital to improve the accuracy of early diagnostic tools. Current computational studies of stenosis use mathematical models, such as laminar and k–omega shear stress transport (SST) models, available in ansys (Fluent and CFX), openfoam, and comsol software packages. Users can adjust boundary conditions, such as inlet velocity and outlet pressure using user-defined functions (UDFs) with different expressions and constant values. However, currently there is no rule over what to impose at these boundaries, and previous studies have used various assumptions, such as rigid artery wall, one-way fluid–structure interaction (FSI) or two-way FSI, and the blood's Newtonian or non-Newtonian material properties. This variety in construction has associated deviations of the models from the clinical data and lessens the value of the models as potential diagnostic or predictive tools for medical practitioners. In this study, we examine arterial stenosis models, with severities of 20%, 40%, and 50%, compared with the healthy artery analyzed in terms of strain energy to the artery wall. Additionally, we investigate elastic walls using one-way FSI, comparing with laminar and k–omega SST. These boundary conditions are based on clinical data. The results regarding the strain energy (mJ) behavior along the artery wall show that the k–omega SST model outperforms the laminar model for short arterial segments and under the Newtonian assumption with a no-slip boundary wall and turbulent flow.