Mahmoud A Hafez

Dr. Mahmoud A Hafez

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2006 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
ADAnthony M DiGioia
Anthony M DiGioia
Mahmoud A HafezMahmoud A Hafez
Mahmoud A Hafez
BJBranislav Jaramaz
Branislav Jaramaz
TLTimothy J Levison
Timothy J Levison
JMJames E Moody
James E Moody
We prospectively obtained preoperative and 3-month postoperative lateral pelvic radiographs in the standing and sitting positions from 84 patients who underwent total hip arthroplasty. We measured pelvic orientation (flexion extension) using the anterior pelvic plane as defined by the anterior superior iliac spines and pubic tubercles as references. There was a trend towards upright pelvic alignment when standing, with a mean anterior pelvic plane angle of 1.2° (range, −22°-+27°). In the sitting position the pelvis tended to extend posteriorly, with a mean anterior pelvic plane angle of −36.2° (range, −64°-+4°). There was a wide variation in the arc of pelvic flexion extension as patients moved from standing to sitting, with arc of pelvic motion in some patients as mobile as 70° and in others as stiff as 5°. There was no significant variation between males and females or between preoperative and postoperative pelvic flexion extension. There were substantial variations in pelvic orientation when comparing standing and sitting for an individual patient and between different patients. This variation can be unpredictable, and may influence implant alignment and stability after total hip arthroplasty. Level of Evidence: Level II, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

1 March 2006 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
Mahmoud A HafezMahmoud A Hafez
Mahmoud A Hafez
KCK L Chelule
K L Chelule
BSB B Seedhom
B B Seedhom
KSK P Frcs Sherman
K P Frcs Sherman
Current techniques used for total knee arthroplasty rely on conventional instrumentation that violates the intramedullary canals. Accuracy of the instrumentation is questionable, and assembly and disposal of the numerous pieces is time consuming. Navigation techniques are more accurate, but their broad application is limited by cost and complexity. We aimed to prove a new concept of computer-assisted preoperative planning to provide patient-specific templates that can replace conventional instruments. Computed tomography-based planning was used to design two virtual templates. Using rapid prototyping technology, virtual templates were transferred into physical templates (cutting blocks) with surfaces that matched the distal femur and proximal tibia. We performed 45 total knee arthroplasties on 16 cadaveric and 29 plastic knees, including a comparative trial against conventional instrumentations. All operations were performed using patient-specific templates with no conventional instrumentations, intramedullary perforation, tracking, or registration. The mean time for bone cutting was 9 minutes with a surgical assistant and 11 minutes without an assistant. Computer-assisted analyses of six random computed tomography scans showed mean errors for alignment and bone resection within 1.7° and 0.8 mm (maximum, 2.3° and 1.2 mm, respectively). Patient-specific templates are a practical alternative to conventional instrumentations, but additional clinical validation is required before clinical use.

1 March 2008 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
PMP. E. Murtha
P. E. Murtha
Mahmoud A HafezMahmoud A Hafez
Mahmoud A Hafez
BJB. Jaramaz
B. Jaramaz
ADA. M. DiGioia
A. M. DiGioia
Three-dimensional surface models of the normal hemipelvis derived from volumetric CT data on 42 patients were used to determine the radius, depth and orientation of the native acetabulum. A sphere fitted to the lunate surface and a plane matched to the acetabular rim were used to calculate the radius, depth and anatomical orientation of the acetabulum. For the 22 females the mean acetabular abduction, anteversion, radius and normalised depth were 57.1° (50.7° to 66.8°), 24.1° (14.0° to 33.3°), 25 mm (21.7 to 30.3) and 0.79 mm (0.56 to 1.04), respectively. The same parameters for the 20 males were 55.5° (47.7° to 65.9°), 19.3° (8.5° to 32.3°), 26.7 mm (24.5 to 28.7) and 0.85 mm (0.65 to 0.99), respectively. The orientation of the native acetabulum did not match the safe zone for acetabular component placement described by Lewinnek. During total hip replacement surgeons should be aware that the average abduction angle of the native acetabulum exceeds that of the safe zone angle. If the concept of the safe zone angle is followed, abduction of the acetabular component should be less than the abduction of the native acetabulum by approximately 10°.

21 April 2005 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Closed access
PDF file
Mahmoud A HafezMahmoud A Hafez
Mahmoud A Hafez
RSR. M. Smith
R. M. Smith
SMS. J. Matthews
S. J. Matthews
GKG. Kalap
G. Kalap
KSK. P. Sherman
K. P. Sherman

1 December 2013 in The Knee
Verified
Journal Article
Closed access
ETEmmanuel Thienpont
Emmanuel Thienpont
FPFrederic Paternostre
Frederic Paternostre
MPMartin Pietsch
Martin Pietsch
Mahmoud A HafezMahmoud A Hafez
Mahmoud A Hafez
Stephen HowellStephen Howell
Stephen Howell

Verified
Journal Article
Open access
PDF file
CRCarlo Luca Romanò
Carlo Luca Romanò
HAHazem Alkhawashki
Hazem Alkhawashki
TBThami Benzakour
Thami Benzakour
SBSvetlana Bozhkova
Svetlana Bozhkova
HSHernán del Sel
Hernán del Sel
Lorenzo DragoLorenzo Drago
Lorenzo Drago
The definition of peri-prosthetic joint infection (PJI) has a strong impact on the diagnostic pathway and on treatment decisions. In the last decade, at least five different definitions of peri-prosthetic joint infection (PJI) have been proposed, each one with intrinsic limitations. In order to move a step forward, the World Association against Infection in Orthopedics and Trauma (W.A.I.O.T.) has studied a possible alternative solution, based on three parameters: 1. the relative ability of each diagnostic test or procedure to Rule OUT and/or to Rule IN a PJI; 2. the clinical presentation; 3. the distinction between pre/intra-operative findings and post-operative confirmation. According to the WAIOT definition, any positive Rule IN test (a test with a specificity > 90%) scores +1, while a negative Rule OUT test (a test with a sensitivity > 90%) scores −1. When a minimum of two Rule IN and two Rule OUT tests are performed in a given patient, the balance between positive and negative tests, interpreted in the light of the clinical presentation and of the post-operative findings, allows to identify five different conditions: High-Grade PJI (score ≥ 1), Low-Grade PJI (≥0), Biofilm-related implant malfunction, Contamination and No infection (all scoring < 0). The proposed definition leaves the physician free to choose among different tests with similar sensitivity or specificity, on the basis of medical, logistical and economic considerations, while novel tests or diagnostic procedures can be implemented in the definition at any time, provided that they meet the required sensitivity and/or specificity thresholds. Key procedures to confirm or to exclude the diagnosis of PJI remain post-operative histological and microbiological analysis; in this regard, given the biofilm-related nature of PJI, microbiological investigations should be conducted with proper sampling, closed transport systems, antibiofilm processing of tissue samples and explanted biomaterials, and prolonged cultures. The proposed WAIOT definition is the result of an international, multidisciplinary effort. Next step will be a large scale, multicenter clinical validation trial.