Shigeru Toyama

Dr. Shigeru Toyama

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2000 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
STShigeru Toyama
Shigeru Toyama
NDNarumasa Doumae
Narumasa Doumae
ASAtsumu Shoji
Atsumu Shoji
YIYoshihito Ikariyama
Yoshihito Ikariyama

1 January 2012 in Frontiers in Neurology
Verified
Journal Article
Open access
PDF file
STShigeru Toyama
Shigeru Toyama
KTKouji Takano
Kouji Takano
KKKenji Kansaku
Kenji Kansaku
A non-invasive brain–machine interface (BMI) or brain–computer interface is a technology for helping individuals with disabilities and utilizes neurophysiological signals from the brain to control external machines or computers without requiring surgery. However, when applying electroencephalography (EEG) methodology, users must place EEG electrodes on the scalp each time, and the development of easy-to-use electrodes for clinical use is required. In this study, we developed a conductive non-adhesive solid-gel electrode for practical non-invasive BMIs. We performed basic material testing, including examining the volume resistivity, viscoelasticity, and moisture-retention properties of the solid-gel. Then, we compared the performance of the solid-gel, a conventional paste, and an in-house metal-pin-based electrode using impedance measurements and P300-BMI testing. The solid-gel was observed to be conductive (volume resistivity 13.2 Ωcm) and soft (complex modulus 105.4 kPa), and it remained wet for a prolonged period (>10 h) in a dry environment. Impedance measurements revealed that the impedance of the solid-gel-based and conventional paste-based electrodes was superior to that of the pin-based electrode. The EEG measurement suggested that the signals obtained with the solid-gel electrode were comparable to those with the conventional paste-based electrode. Moreover, the P300-BMI study suggested that systems using the solid-gel or pin-based electrodes were effective. One of the advantages of the solid-gel is that it does not require cleaning after use, whereas the conventional paste adheres to the hair, which requires washing. Furthermore, the solid-gel electrode was not painful compared with a metal-pin electrode. Taken together, the results suggest that the solid-gel electrode worked well for practical BMIs and could be useful for bedridden patients such as those with amyotrophic lateral sclerosis.

1 March 2003 in Analytical Biochemistry
Verified
Journal Article
Closed access
TKTetsuo Kuwabara
Tetsuo Kuwabara
TNTomohide Noda
Tomohide Noda
HOHideki Ohtake
Hideki Ohtake
TOToshihito Ohtake
Toshihito Ohtake
STShigeru Toyama
Shigeru Toyama
YIYoshihito Ikariyama
Yoshihito Ikariyama

1 September 1998 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
STShigeru Toyama
Shigeru Toyama
ASAtsumu Shoji
Atsumu Shoji
YYYasuhiko Yoshida
Yasuhiko Yoshida
SYShigeru Yamauchi
Shigeru Yamauchi
YIYoshihito Ikariyama
Yoshihito Ikariyama

31 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
STShigeru Toyama
Shigeru Toyama
YTYasuhiro Tanaka
Yasuhiro Tanaka
SSSatoshi SHIROGANE
Satoshi SHIROGANE
TNTakashi Nakamura
Takashi Nakamura
TUTokio Umino
Tokio Umino
HIHiroshi Igarashi
Hiroshi Igarashi
A sheet-type shear force sensor and a measurement system for the sensor were developed. The sensor has an original structure where a liquid electrolyte is filled in a space composed of two electrode-patterned polymer films and an elastic rubber ring. When a shear force is applied on the surface of the sensor, the two electrode-patterned films mutually move so that the distance between the internal electrodes of the sensor changes, resulting in current increase or decrease between the electrodes. Therefore, the shear force can be calculated by monitoring the current between the electrodes. Moreover, it is possible to measure two-dimensional shear force given that the sensor has multiple electrodes. The diameter and thickness of the sensor head were 10 mm and 0.7 mm, respectively. Additionally, we also developed a measurement system that drives the sensor, corrects the baseline of the raw sensor output, displays data, and stores data as a computer file. Though the raw sensor output was considerably affected by the surrounding temperature, the influence of temperature was drastically decreased by introducing a simple arithmetical calculation. Moreover, the influence of pressure simultaneously decreased after the same calculation process. A demonstrative measurement using the sensor revealed the practical usefulness for on-site monitoring.

1 July 2002 in Electrochemistry Communications
Verified
Journal Article
Closed access
STShigeru Toyama
Shigeru Toyama
OTOsamu Takei
Osamu Takei
MTMasashi Tsuge
Masashi Tsuge
RURon Usami
Ron Usami
KHKoki Horikoshi
Koki Horikoshi
SKSeishi Kato
Seishi Kato