Purpose: To compare the visual performance of soft contact lenses reported to reduce myopia progression. Methods: In a double-blind, randomized, crossover trial, 30 non-presbyopic myopes wore MiSight™, center-distance Proclear® Multifocal (+2.00 D add), and two prototype lenses for 1 week each. High- and low-contrast visual acuities at 6 m, and 70 and 40 cm; stereopsis at 40 cm; accommodative facility at 33 cm; and horizontal phoria at 3 m and 33 cm were measured after 1 week. Subjective performance was assessed on a numeric rating scale for vision clarity, lack of ghosting, vision stability, haloes, overall vision satisfaction, and ocular comfort. Frequency of eye-strain symptoms and willingness to purchase lenses were also reported with categorical responses. Participants reported wearing times (total and visually acceptable). Linear mixed models and chi-square tests were employed in analysis with level of significance set at 5%. Theoretical optical performance of all lenses was assessed with schematic myopic model eyes (−1.00, −3.00, and −6.00 D) by comparing the slope of the edge spread function (ESF), an indicator for optical performance/resolution and the blur patch size of the line spread function, an indicator for contrast, between the lenses. Results: Proclear Multifocal and MiSight provided the best distance acuities. However, the prototype lenses were rated significantly higher for many subjective variables, and there were no subjective variables where commercial lenses were rated significantly higher than the prototypes. Theoretical optical performance showed steeper slopes of the ESF and greater blur patch sizes of the LSP with commercial lenses, supporting the clinical findings of better visual acuities but reduced subjective performance. Participants wore prototypes longer and reported their vision acceptable for longer each day compared to MiSight. Both prototypes had the highest willingness-to-purchase rate. Conclusions: The prototypes were better tolerated by myopes compared to the commercial soft contact lenses currently used for slowing myopia progression.
1 January 2012 in Eye & Contact Lens: Science & Clinical Practice
Objectives: The aim of this study was to investigate the relationship between solution-induced corneal staining (SICS) and silicone hydrogel contact lens comfort and vision. Methods: A retrospective analysis of a series of open-label studies were conducted with 24 groups of approximately 40 participants, each wearing 1 of 6 silicone hydrogel contact lenses with 1 of 4 lens care products bilaterally for 3 months of daily wear. The presence of SICS and subjective ocular ratings were collected at 2 weeks and at 1 and 3 months. Results: A total of 1,051 participants were enrolled. The participants with SICS rated significantly less favorably than did the participants without SICS for comfort during the day (7.9±1.7 vs. 8.5±1.4, P=0.03), comfort at the end of the day (6.6±2.1 vs. 7.4±1.9, P=0.03), overall dryness (7.4±1.9 vs. 8.0±1.7, P=0.04), dryness at the end of the day (6.7±2.2 vs. 7.5±2.1, P=0.01), feelings of burning and stinging (8.5±2.0 vs. 8.9±1.8, P=0.02), and overall vision (8.2±1.6 vs. 8.7±1.3, P<0.001). Conclusions: The participants with SICS had lower subjective comfort and vision compared with those who did not experience SICS.
To compare the visual performance of prototype contact lenses designed via deliberate manipulation of higher-order spherical aberrations to extend-depth-of-focus with two commercial multifocals, after 1 week of lens wear. In a prospective, participant-masked, cross-over, randomized, 1-week dispensing clinical-trial, 43 presbyopes [age: 42-63 years] each wore AIROPTIX Aqua multifocal (AOMF), ACUVUE OASYS for presbyopia (AOP) and extended-depth-of-focus prototypes (EDOF) appropriate to their add requirements. Measurements comprised high-contrast-visual-acuity (HCVA) at 6m, 70cm, 50cm and 40cm; low-contrast-visual-acuity (LCVA) and contrast-sensitivity (CS) at 6m and stereopsis at 40cm. A self-administered questionnaire on a numeric-rating-scale (1-10) assessed subjective visual performance comprising clarity-of-vision and lack-of-ghosting at various distances during day/night-viewing conditions and overall-vision-satisfaction. EDOF was significantly better than AOMF and AOP for HCVA averaged across distances (p≤0.038); significantly worse than AOMF for LCVA (p=0.021) and significantly worse than AOMF for CS in medium and high add-groups (p=0.006). None of these differences were clinically significant (≤2 letters). EDOF was significantly better than AOMF and AOP for mean stereoacuity (36 and 13 seconds-of-arc, respectively: p≤0.05). For clarity-of-vision, EDOF was significantly better than AOP at all distances and AOMF at intermediate and near (p≤0.028). For lack-of-ghosting averaged across distances, EDOF was significantly better than AOP (p<0.001) but not AOMF (p=0.186). EDOF was significantly better than AOMF and AOP for overall-vision-satisfaction (p≤0.024). EDOF provides better intermediate and near vision performance than either AOMF or AOP with no difference for distance vision after 1 week of lens wear.
1 September 2018 in Eye & Contact Lens: Science & Clinical Practice
Objective: To compare subjective, objective and safety performance of silicone hydrogel (SiHy) daily disposable (DD) with hydrogel (Hy) DD contact lenses. Method: Retrospective analysis on approximately 40 participants (Px) each in 5 trials. Lenses grouped into SiHy (delefilcon A, somofilcon A, narafilcon A) and Hy (omafilcon A, nelfilcon A). Participants attended follow-up visits at baseline, 2 weeks, 1 and 3 months. Subjective ratings (1–10 scale), adverse events (percentage of Px), physiological variables (0–4 scale), and wearing time were collected at each visit and compared between groups. Result: Trials enrolled 201 Px totally. No differences in age, sex, and lens wear experience were found between SiHy and Hy groups (P≥0.09). There was greater increase in limbal redness from baseline in Hy group (0.18±0.38 vs. 0.02±0.47, P<0.001), whereas conjunctival staining and indentation were less in Hy group (P<0.001). No differences in comfortable wearing time were found between groups (P=0.41), and comfort at insertion, during day, and end of day was also no different (P≥0.71). Incidence of corneal infiltrative events (SiHy vs. Hy: 6.7% vs. 2.5%; P=0.32) and mechanical adverse events (SiHy vs. Hy: 0.0% vs. 0.0%; P=1.00) were no different. Conclusion: Though some statistical significance was found between the groups, these differences were within measurement error. Neither material types showed superiority in comfort, and adverse event rates were low with both material types. These findings suggest that choice of material is a patient and practitioner preference; however, for patients at risk of hypoxia-related complications, SiHy materials should be considered.