In order to comply with the trend of global climate change, countries are gradually promoting energy conservation and emission reduction, and prefabricated buildings have become one of the main paths for the construction industry to develop towards carbon peaking and carbon neutrality goals. This paper takes the box-shaped column flange connection achieved by plug welding-core sleeve in the dormitory building of Tongzhou Campus of the Affiliated High School of Capital Normal University in China as the research object. Based on the consumption quota of prefabricated construction projects and the actual project quantity, the carbon emissions of steel structure column connection joints at different phases are calculated by the emission factor method, and it is proposed that the production consumption of building materials plays a key role in energy conservation and emission reduction. This paper concludes that the box-shaped column flange connection achieved by plug welding-core sleeve in the construction phase of an assembled steel building emits 49.5% less carbon dioxide than a conventional full fusion-welded joint. And the reason for the high carbon emissions of the latter is mainly from the amount of materials and machinery required for full penetration welding. It further affirms the green and environmental protection effect of the assembled steel structure plug welding-core sleeve flange connection joint in actual projects, and provides a reference for related research.
This study reviewed some simplified methods of finite element analysis (FEA) for connections in cold-formed steel (CFS) structure, and summarized eight simplified methods divided into three categories. Shear performance tests were performed for six groups of self-piercing riveted (SPR) connection in CFS. A constitutive model of shear behavior for SPR connections was proposed, which was simplified from the load–displacement curve of shear performance test results. The models of SPR connection were established in ABAQUS by the eight simplified methods, and then the FEA results and the test results were compared. The applicable scope of each simplified model was explored, and a simplified method of FEA that was most suitable for the shear behavior of the CFS-SPR connection was proposed. Moreover, the shear performance test of the CFS shear wall with SPR was conducted by considering the rivet spacing, and failure modes and load–deformation curves were obtained. On this basis, numerical models of the CFS-SPR connection shear wall were established. By comparing the test results and the FEA results for the CFS-SPR connection shear wall, the feasibility of a simplified method of FEA applied to the CFS-SPR connection was verified. The main failure modes of the CFS-SPR connection were that the rivet tail pulled out from the bottom sheet and the rivet head pulled over from the top sheet. The SPR connection of the CFS frame could be simplified with a pin or a fastener element, and the SPR connection between the steel frame and the sheathing could be simulated by a Cartesian connector or a Spring2 element. The FEA results were highly similar to the test results for the CFS-SPR shear wall.
19 January 2024 in Journal of Constructional Steel Research