James W. Pritchett

Dr. James W. Pritchett


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2015 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
JPJames W. Pritchett
James W. Pritchett
One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42–84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20–24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%–93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%–96 %) at 23 years. At followup, the mean age of the patients was 84 years (range, 63–101 years), the mean flexion was 117° (range, 90°–130°), the mean American Knee Society score improved from a preoperative mean of 42 (range, 26–49) to 91 (range, 61–100; p < .001). Twenty-two knees in 21 patients (5.6%) were revised, most commonly because of polyethylene wear. ACL sacrifice may be an unnecessary concession during TKA. This study found satisfactory survivorship and function after more than 20 years of use for patients receiving a bicruciate-retaining TKA implant. A TKA that preserves cruciate ligaments provides a stable, well-functioning knee with a low likelihood of revision at long-term followup. Retaining both cruciate ligaments during knee arthroplasty is an attractive concept that is worth considering. Level IV, therapeutic study.

1 July 2011 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
JPJames W. Pritchett
James W. Pritchett

15 May 2012 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
JPJames W. Pritchett
James W. Pritchett
LHLouis S. Habryl
Louis S. Habryl
Background Trapeziometacarpal joint osteoarthritis is a painful, disabling condition that primarily affects women who are postmenopausal. Arthroplasty has been performed to treat this condition; however, subluxation has been a problem with all previous implants. We report the results of hemiarthroplasty using a prosthesis designed to address the problems associated with previous implants. Questions/purposes We wished to (1) determine if this prosthesis results in pain relief and functional improvement and preserves the appearance of the thumb, (2) assess the prosthetic reconstruction during followup, (3) assess complications that occur with the use of this prosthesis, and (4) determine the survivorship of this prosthesis. Methods We performed 159 basal joint hemiarthroplasties (138 patients) to treat osteoarthritis of the trapeziometacarpal joint. The mean age of the patients was 63 years, 78% were women, and all had Eaton-Littler Stage II or III changes. Only the damaged articular surfaces of the metacarpal and trapezium were excised; no tendon grafts or transfers were performed. Seven patients (seven thumbs) were lost to followup and seven (nine thumbs) died, leaving 124 patients (143 thumbs) for review. Clinical and radiographic assessments were made preoperatively, 12 weeks postoperatively, and annually thereafter. Minimum followup was 35 months (mean, 72.1 months; range, 35–120 months). Results At latest followup, pain relief occurred in 135 thumbs, function improved in 138 thumbs, 139 thumbs were excellent or good in overall assessment, and 142 thumbs had good or excellent cosmetic appearance. The mean tip pinch improved from 4.9 kg preoperatively to 6.44 kg postoperatively. Mean postoperative Buck-Gramcko score was 49 (excellent); overall Kaplan-Meier analysis with revision as the end point showed 94% implant survivorship at a mean followup of 72.1 months. Conclusions Our results are superior to those of other implants and support continued use of this implant. Studies with longer followup are required to confirm these results. Level of Evidence Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

1 January 2011 in Journal of Long-Term Effects of Medical Implants
Verified
Journal Article
Closed access
JPJames W. Pritchett
James W. Pritchett
In order to determine the magnitude of temperature increases in resurfaced hips, temperature sensors were placed percutaneously in both hip joints of 12 volunteer patients who had 1 or both joints resurfaced. Temperature recordings were made with patients at rest (baseline) and after patients walked for 20 and 60 minutes. The hip resurfacing procedures were performed 12 to 36 months prior to this study using 9 different acetabular bearing surface components. At baseline (resting), a ceramic femoral prosthesis articulating with a poly-ether-ether-ketone (PEEK) acetabular prosthesis generated a temperature increase of 4°C compared to a normal contralateral hip. After 60 minutes of walking, a ceramic femoral prosthesis articulating with a polyurethane acetabular prosthesis generated a temperature increase of 5°C, whereas a ceramic femoral prosthesis articulating with a metal acetabular prosthesis generated a temperature increase of 6°C, a cobalt-chromium alloy femoral prosthesis on a polyethylene acetabular prosthesis generated a temperature increase of 7°C, and a cobalt-chromium alloy metal-on-metal prosthesis generated a temperature increase of 8°C. Resurfaced hips generate more heat than arthritic and normal hips, and arthritic hips generate more heat than normal hips. A resurfaced hip with a ceramic femoral and PEEK or polyurethane acetabulum generated less heat than a resurfaced hip of the same design using a cobalt-chromium femur and either cobalt-chromium, or polyethylene for the acetabulum. Frictional heat generated in a resurfaced hip is not immediately dissipated and may result in increased bearing surface wear. Extended periods of elevated temperature within joints may inhibit periarticular cell growth and perhaps contribute to bone resorption or component loosening over the long term.

1 January 2006 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
JPJames W. Pritchett
James W. Pritchett
Temperature sensors were placed in 50 knees in 25 patients who had one or both joints replaced. Temperature recordings were made before walking, after walking, and after cycling. The heat generated in healthy, arthritic, and replaced knees was measured. The knee replacements were done using eight different prostheses. A rotating hinge knee prosthesis generated a temperature increase of 7 degrees C in 20 minutes and 9 degrees C in 40 minutes. An unconstrained ceramic femoral prosthesis articulating with a polyethylene tibial prosthesis generated a temperature increase of 4 degrees C compared with a healthy resting knee. The other designs using a cobalt-chrome alloy and high-density polyethylene had temperature increases of 5 degrees-7 degrees C with exercise. Frictional heat generated in a prosthetic knee is not immediately dissipated and may result in wear, creep, and other degenerative processes in the high-density polyethylene. Extended periods of elevated temperature in joints may inhibit cell growth and perhaps contribute to adverse performance via bone resorption or component loosening. Prosthetic knees generate more heat with activity than healthy or arthritic knees. More-constrained knee prostheses generate more heat than less-constrained prostheses. A knee with a ceramic femoral component generates less heat than a knee with the same design using a cobalt-chromium alloy.

1 May 2008 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
JPJames W. Pritchett
James W. Pritchett
Hip resurfacing is an attractive concept because it preserves rather than removes the femoral head and neck. Most early designs had high failure rates, but one unique design had a femoral stem. Because that particular device appeared to have better implant survival, this study assessed the clinical outcome and long-term survivorship of a hip resurfacing prosthesis. Four hundred forty-five patients (561 hips) were retrospectively reviewed after a minimum of 20 years' followup or until death; 23 additional patients were lost to followup. Patients received a metal femoral prosthesis with a small curved stem. Three types of acetabular reconstructions were used: (1) cemented polyurethane; (2) metal-on-metal; and (3) polyethylene secured with cement or used as the liner of a two-piece porous-coated implant. Long-term results were favorable with the metal-on-metal combination only. The mean overall Harris hip score was 92 at 2 years of followup. None of the 121 patients (133 hips) who received metal-on-metal articulation experienced failure. The failure rate with polyurethane was 100%, and the failure rate with cemented polyethylene was 41%. Hip resurfacing with a curved-stem femoral component had a durable clinical outcome when a metal-on-metal articulation was used. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.