Ana Carolina Dias Barreto de Souza

Ms. Ana Carolina Dias Barreto de Souza

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
ASAna Carolina Dias Barreto de Souza
Ana Carolina Dias Barreto de Souza
FVFilipe Menezes de Vasconcelos
Filipe Menezes de Vasconcelos
GMGabriel Abel Massunanga Moreira
Gabriel Abel Massunanga Moreira
JAJoão Alves
João Alves
Jonathan Muñoz TaboraJonathan Muñoz Tabora
Jonathan Muñoz Tabora
ANAndreia Antloga Do Nascimento
Andreia Antloga Do Nascimento
The growth of electric vehicles (EVs) and their integration into existing and future buildings bring new considerations for energy efficiency (EE) and balance when combined with renewable energy. However, for buildings with an energy efficiency label, such as Near Zero Energy Building (NZEB) or Positive Energy Building (PEB), the introduction of EVs may result in the declassification of the EE label due to the additional energy required for the charging infrastructure. This underscores the increasing relevance of demand-side management techniques to effectively manage and utilize energy consumption and generation in buildings. This paper evaluates the influence of electric vehicle (EV) charging on NZEB/PEB-labeled buildings of the Brazilian Building Labeling Program (PBE Edifica). Utilizing on-site surveys, computational modeling, and thermos-energetic analysis with software tools such as OpenStudio v. 1.1.0 and EnergyPlus v. 9.4.0, an energy classification was conducted in a building in the city of Belem, State of Para, Brazil. Subsequently, power flow simulations employing probabilistic models and Monte Carlo approaches were executed in the OpenDSS software v. 10.0.0.2 to examine the impact of EV integration, both with and without the implementation of demand-side management techniques. Analyses using the labeling methodology demonstrated that the building has EE level C and NZEB self-sufficiency classification. The assessment of the impact of EV integration on the building’s total energy consumption in the base (current) scenario was carried out in two scenarios, with (2) and without (1) supply management. Scenario 01 generated a 69.28% increase in energy consumption, reducing the EE level to D and resulting in the loss of the NZEB class. Scenario 02 resulted in a smaller increase in energy consumption of 40.50%, and guaranteed the return of the NZEB class lost in scenario 1, but it was not enough to return the EE level to class C. The results highlight the need for immediate and comprehensive energy management strategies, as the findings show that the two scenarios present a difference of 41.55% in energy consumption. Nonetheless, these strategies are not enough if other consumption restrictions or energy efficiency measures are not applied to other building systems.

7 October 2024 in Encontro Nacional de Tecnologia Do Ambiente ConstruÍdo
Verified
Conference Paper
Open access
PDF file
BCBianca Beatriz Silva Correa
Bianca Beatriz Silva Correa
KFKlayton Marcondes Ferreira
Klayton Marcondes Ferreira
ASAna Beatriz Rocha Sousa
Ana Beatriz Rocha Sousa
ASAna Carolina Dias Barreto de Souza
Ana Carolina Dias Barreto de Souza
FVFilipe Menezes de Vasconcelos
Filipe Menezes de Vasconcelos
CCCarminda Célia Moura de Moura Carvalho
Carminda Célia Moura de Moura Carvalho
As edificações representam 50% do consumo da produção da energia elétrica do Brasil. O estudo propõe o retrofit do sistema de iluminação para um prédio público, buscando demonstrar a eficácia desse tipo de projeto que incorpora medidas de eficiência energética para a redução do consumo de energia, especialmente no contexto de um retrofit. Por meio de uma abordagem metodológica robusta, que inclui a coleta de dados in loco, simulação computacional e etiquetagem do sistema de iluminação por meio da INI-C, foi possível avaliar de forma precisa o impacto dessas intervenções na redução do consumo do sistema. Ao final, a aplicação da referida se mostrou efetiva, pois a redução de consumo foi de 68,15%, porcentual maior que o associado a edificações construídas que é de 30%, segundo a literatura. Realizou-se o cálculo dos custos associados à implementação e da viabilidade financeira, que mostra a viabilidade econômica do projeto, tendo um payback de 1,28 anos. Estes resultados mostram o potencial de redução de consumo da edificação e demonstram que o investimento nesse tipo de projeto propagam a eficiência energética e são benéficos para o conforto dos usuários do local, pois demonstra com dados palpáveis a redução de consumo de projetos que associam retrofit e eficiência energética.