Wenning Di

Dr. Wenning Di


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2015 in Sensors
Verified
Journal Article
Open access
PDF file
DLDongxu Liu
Dongxu Liu
QYQingwen Yue
Qingwen Yue
JDJi Deng
Ji Deng
DLDongxu Liu
Dongxu Liu
XLXiaobing Li
Xiaobing Li
Haosu LuoHaosu Luo
Haosu Luo
5–6 MHz PMNT/epoxy 1–3 composites were prepared by a modified dice-and-fill method. They exhibit excellent properties for ultrasonic transducer applications, such as ultrahigh thickness electromechanical coupling coefficient kt (85.7%), large piezoelectric coefficient d33 (1209 pC/N), and relatively low acoustic impedance Z (1.82 × 107 kg/(m2·s)). Besides, two types of Time-of-Flight Diffraction (TOFD) ultrasonic transducers have been designed, fabricated, and characterized, which have different matching layer schemes with the acoustic impedance of 4.8 and 5.7 × 106 kg/(m2·s), respectively. In the detection on a backwall of 12.7 mm polystyrene, the former exhibits higher detectivity, the relative pulse-echo sensitivity and −6 dB relative bandwidth are −21.93 dB and 102.7%, respectively, while the later exhibits broader bandwidth, the relative pulse-echo sensitivity and −6 dB relative bandwidth are −24.08 dB and 117.3%, respectively. These TOFD ultrasonic transducers based on PMNT/epoxy 1–3 composite exhibit considerably improved performance over the commercial PZT/epoxy 1–3 composite TOFD ultrasonic transducer.

7 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
RCrui chen
rui chen
Jie JiaoJie Jiao
Jie Jiao
ZCZiyun Chen
Ziyun Chen
YWYuhang Wang
Yuhang Wang
AAAA AAAAA
AA AAAAA
Haosu LuoHaosu Luo
Haosu Luo
With the popularity of electric vehicles, the ever-increasing demand for high-capacity batteries highlights the need for monitoring the health status of batteries. In this article, we proposed a magnetic imaging technique (MIT) to investigate the health status of power batteries nondestructively. This technique is based on a magnetic sensor array, which consists of a 16-channel high-performance magnetoelectric sensor, and the noise equivalent magnetic induction (NEB) of each channel reaches 3–5 pT/Hz1/2@10 Hz. The distribution of the magnetic field is imaged by scanning the magnetic field variation of different positions on the surface. Therefore, the areas of magnetic anomalies are identified by distinguishing different magnetic field abnormal results. and it may be possible to classify the battery failure, so as to put forward suggestions on the use of the battery. This magnetic imaging method expands the application field of this high-performance magnetoelectric sensor and contributes to the battery’s safety monitoring. Meanwhile, it may also act as an important role in other nondestructive testing fields.

19 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
QYQingwen Yue
Qingwen Yue
DLDongxu Liu
Dongxu Liu
WWWei Wang
Wei Wang
WDWenning Di
Wenning Di
DLDongxu Liu
Dongxu Liu
Haosu LuoHaosu Luo
Haosu Luo
Doppler sonographic measurement of flow velocity in the basal cerebral arteries through the intact skull was developed using a pulsed Doppler technique and 2 MHz emitting frequency. Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) were chosen to be the piezoelectric transducer material due to their ultrahigh piezoelectric coefficients, high electromechanical coupling coefficients and low dielectric loss. The pulse-echo response of the transducer was measured using the conventional pulse-echo method in a water bath at room temperature. The −6 dB bandwidth of the transducer is 68.4% and the sensitivity is −17.4 dB. In order to get a good match between transducer and detection system, different transmission powers have been regulated by changing the impedance of the transmitting electric circuit. In the middle cerebral artery (MCA) measurement photograph results, as the transmission power is increasing, the detection results become clearer and clearer. A comparison at the same transmission power for different transducers shows that the detection photograph obtained by the crystal transducer was clearer than that obtained with a commercial transducer, which should make it easier for doctors to find the cerebral arteries.

6 July 2020 in Journal of Materials Science: Materials in Electronics
Verified
Journal Article
Closed access
PDF file
FHFei Hu
Fei Hu
RZRongfeng Zhu
Rongfeng Zhu
LLLi Lu
Li Lu
ZCZiyun Chen
Ziyun Chen
RCRui Chen
Rui Chen
Haosu LuoHaosu Luo
Haosu Luo

4 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
RZRongfeng Zhu
Rongfeng Zhu
JZJing Zhao
Jing Zhao
Jianwei ChenJianwei Chen
Jianwei Chen
Bijun FangBijun Fang
Bijun Fang
HXHaiqing Xu
Haiqing Xu
Haosu LuoHaosu Luo
Haosu Luo
Mn:0.15Pb(In1/2Nb1/2)O3-0.55Pb(Mg1/3Nb2/3)O3-0.30PbTiO3 (Mn:PIMNT) pyroelectric chips were prepared by a two-step annealing method. For the two steps, annealing temperatures dependence of microstructure, defects, surface stress, surface roughness, dielectric properties and pyroelectric properties were studied comprehensively. The controlling factors influencing the pyroelectric properties of the Mn:PIMNT crystals were analyzed and the optimum annealing temperature ranges for the two steps were determined: 600–700 °C for the first step and 500–600 °C for the second step. The pyroelectric properties of the thin Mn:PIMNT chips were significantly enhanced by the two-step annealing method via tuning oxygen vacancies and eliminating surface stress. Based on Mn:PIMNT pyroelectric chips annealed at the most favorable conditions (annealed at 600 °C for the first step and 500 °C for the second step), infrared detectors were prepared with specific detectivity D* = 1.63 × 109 cmHz1/2W−1, nearly three times higher than in commercial LiTaO3 detectors.