The related regulations for electric power industry stipulate that CO gas is an important component to be detected when analyzing the gas composition of SF6 equipment. In this study, based on the photoacoustic spectroscopy technology, the quantitative gas detection of CO is carried out. Firstly, in order to avoid the cross-interference effects of other component gases on photoacoustic spectroscopy detection of CO, the characteristic absorption spectrum of CO in 4291.5 cm-1 (which’s wavelength is 2330.2nm) is determined. Secondly, the non-resonant photoacoustic cell is optimized in this study. After that, designing and building a trace gas photoacoustic spectroscopy detection platform around the developed photoacoustic cell, using the built detection platform to perform photoacoustic spectroscopy detection of the concentration of CO, obtaining photoacoustic signals of different concentrations of CO, the photoacoustic signals increase linearly as the concentration increases. With SF6 as the background gas, the lower detection limit of CO gas reaches 20.5 ppm, and with N2 as the background gas, it reaches 5.6 ppm. After all, the influence mechanism of the background gas on the photoacoustic signal is studied, based on the influence mechanism, the lower detection limit of CO with the background gas of different mixing ratios of SF6/N2 is predicted. The verified experiment is basically consistent with the predicted results, which proves the accuracy of the forecast. This study provides guidance for the engineering application of CO photoacoustic spectroscopy detection in SF6 equipment.
Gas detection based on photoacoustic (PA) spectroscopy has attracted extensive attention due to high sensitivity and portability. Herein, to achieve the simultaneously detection of the transformer oil carbide gases, C 2 H 2 and CO, a gas-detection system based on one cantilever beam sensor and single-pass PA cell was proposed. The infrared light beams were coupled by the coarse wavelength division multiplexer (CWDM) and fiber coupler, the vibration of the cantilever beam was measured by the vibration meter, and the gas detection experiment was carried out. The results showed that cantilever could distinguish multiple kinds of acoustic waves, in the frequency domain, the simultaneous detection of C 2 H 2 and CO can be realized by extracting the fast Fourier transform (FFT) values at 20 and 55 Hz. The system exhibits a good repeatability, and a linear relationship between the pure PA signals and gas concentration was confirmed with the correlation coefficient greater than 0.9. In addition, the pure PA signals also show linear trend with the coupling ratio. The minimum detection limit and resolution of C 2 H 2 are 0.27 and 0.12 per part million (ppm), respectively, when the CWDM is used to couple the light beams, whereas they are 23.42 and 14.94 ppm of CO. Especially, it was found that the PA signals have good superposition whether the modulation frequencies of the external lasers are same or not. This article provides an idea for simultaneous detection of multicomponent in gas mixture.
As an alternative to sulfur hexafluoride (SF 6 ) with great potential for application, heptafluoroisobutyronitrile–carbon dioxide (C 4 F 7 N–CO 2 ) gas mixture has been applied in various gas-insulated equipment. The insulation performance of the gas mixture is closely related to the mixing ratio. Therefore, accurate quantification of C 4 F 7 N in the C 4 F 7 N–CO 2 gas mixture has very important engineering significance. At present, there are few reports on the rapid quantitative detection of the concentration of C 4 F 7 N in the gas mixture. In this paper, a rapid analytical method for C 4 F 7 N concentration based on ultraviolet (UV) absorption spectroscopy is constructed. The UV spectral characteristics of C 4 F 7 N molecules are calculated by density functional theory. The appropriate bands that can be detected are determined by analyzing the calculated results. A concentration detection system of C 4 F 7 N based on UV absorption spectroscopy is built. Through analysis of the calculated results and experimental results, a quantitative detection method of C 4 F 7 N in the C 4 F 7 N/CO 2 gas mixture is determined. The method can achieve accurate detection of the concentration of the gas mixture in the conventional application range (including 4–10% C 4 F 7 N). The coefficient of the determination R 2 of the concentration inversion curve reaches 0.999 and the inversion error ratio does not exceed 5%. The related research results provide an important reference for the engineering application of the gas mixture.
24 June 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
SO 2 F 2 and SOF 2 are important characteristic decomposition components of SF 6 . Accurate detection of these two gases is helpful for fault diagnosis of gas-insulated switchgear (GIS). In this article, the infrared characteristic peaks of SO 2 F 2 and SOF 2 were obtained by comparing the simulation and experimental infrared spectrum. Then, cross interference analysis was performed with SF 6 characteristic components such as H 2 S, SO 2 , CO, and SF 6 background gas to determine the appropriate detection bands for SO 2 F 2 and SOF 2 . Tunable diode laser absorption spectroscopy (TDLAS) experiment platform was built based on quantum cascade laser with center wavelength at 1506.4 and 1340.2 cm −1 . The concentration of SO 2 F 2 and SOF 2 is detected through this platform. And the concentration information of gas is deduced by detecting the voltage value of second harmonic signal. The experimental results show that, for SO 2 F 2 gas between 1.01 and 19.88 ppm, the $R^{2}$ is 0.989 and the maximum relative error is 2.044%. For SOF 2 gas between 1.03 and 9.00 ppm, the ${R}^{{2}}$ is 0.992 and the maximum relative error is 0.728%. SO 2 gas may cause weak interference to SOF 2 detection, which has some regularities, and the interference can be eliminated by selecting the appropriate SOF 2 fitting linear equation. The research results provide a feasible scheme for the quantitative detection of SO 2 F 2 and SOF 2 gases.
In view of the insufficient signal detection sensitivity of Gas Insulated Switchgear (GIS), partial discharge (PD), ultra-high frequency (UHF), and failure to conform with GIS surface structure when the existing rigid stereo structure UHF sensor is built in, this paper, using rectangular patch antenna equivalent technique, trapezoidal ground plane technique, and coplanar waveguide (CPW) feed line index asymptotic linearization technique, conducts research on a flexible built-in high-sensitivity elliptic monopole antenna. The flexible antenna, with a thickness of only 0.28 mm, can be kept at a voltage standing wave ratio (VSWR) of less than three in the 300 MHz to 3 GHz band under the curvature radius of 0, 100, 300, and 500 mm, and at less than two in the 650 MHz to 3 GHz band. Through the true 220 kV-GIS partial discharge experimental platform built to analyze the high frequency electromagnetic wave detection performance of the built-in flexible antenna, it is shown that the flexible built-in high-sensitivity elliptical monopole antenna designed in this paper can effectively detect the characteristic signals of high-frequency electromagnetic waves emitted by partial discharges with an average discharge amount below 10 pC.