Subchondroplasty is a new minimally invasive surgical technique developed to treat bone marrow lesions (BML) and early osteoarthritis (OA). During the procedure, engineered calcium phosphate compound (CPC) is injected. It is claimed by the manufacturer that during the healing process, the CPC is replaced with new bone. The purpose of this study was to verify the replacement of CPC with new bone after subchondroplasty for the first time in humans. A 76-year old woman was referred for resistant medial knee pain. Standing radiographs showed varus knee OA and magnetic resonance imaging (MRI) revealed BML. She was treated with subchondroplasty of medial femoral condyle. Excellent relief of pain was achieved after procedure. Afterwards, the pain worsened, the radiographs confirmed the OA progression and the patient was treated with a total knee arthroplasty (TKA) 4 years after primary procedure. The resected bone was examined histologically and with micro-computed tomography (CT). Histologically, bone trabeculae of subcortical bone were embedded in the amorphous mass. However, no signs of CPC resorption and/or bone replacement have been found with micro-CT. In short term, excellent pain relief could be expected after the subchondroplasty procedure. However, there was no replacement of CPC with bone and the technique probably did not influence the natural process of knee OA.
The majority of contemporary total hip arthroplasty (THA) implants are constructed from Ti alloys, which are generally believed to generate fewer adverse local tissue reactions (ALTRs) compared to CoCr alloys. This study presents a case of unusual primary THA failure where a substantial release of Ti alloy debris was observed. A 52-year-old active male underwent THA after post-traumatic aseptic necrosis of the femoral head in 2006. Seventeen years after the procedure, the patient presented with groin pain and a restricted range of motion. X-rays revealed the protrusion of the alumina ceramic head through the Ti6Al4V acetabular cup. Trace element analysis indicated significantly elevated levels of serum Ti, Al, and V. CT and MRI confirmed Ti alloy cup failure and a severe ALTR. During revision surgery, it was found that the worn-out ceramic head was in direct contact with the acetabular cup, having protruded through a central hole it had created over time. No acetabular liner was found. Histological analysis of his tissue samples showed wear-induced synovitis with areas of multinucleated foreign body giant cells and the accumulation of numerous metal particles but no acute inflammatory response. Six months after the revision THA, the patient has experienced favourable outcomes. This case provides an instructive illustration for studying the consequences of the substantial release of Ti alloy debris from orthopedic implants.
2 March 2023 in Forensic Science, Medicine and Pathology
We present a case of a complex suicide of a 66-year-old man with a history of several psychiatric disorders. He attempted to commit suicide by inflicting cut wounds on his forearms, wrists, and neck but afterwards changed the method of suicide by using an electric power drill. After several unsuccessful attempts to drill a hole in either his head, thorax, or abdomen, he managed to perforate the common carotid artery on the right side of his neck and subsequently died from exsanguination.
The majority of contemporary total hip arthroplasty (THA) implants are constructed from Ti-alloys, which are generally believed to generate fewer adverse local tissue reactions (ALTR) compared to CoCr-alloys. This study presents a case of unusual primary THA failure where a substantial release of Ti-alloy debris was observed. A 52-year-old active male underwent THA after posttraumatic aseptic necrosis of the femoral head in 2006. Seventeen years after the procedure, the patient presented with groin pain and restricted range of motion. X-rays revealed protrusion of the alumina ceramic head through the Ti6Al4V acetabular cup. Trace element analysis indicated significantly elevated levels of serum Ti, Al and V. CT and MRI confirmed Ti-alloy cup failure and severe ALTR. During revision surgery, the worn-out ceramic head was in direct contact with the acetabular cup, having protruded through the central hole it created over time. Histological analysis of tissue samples showed wear-induced synovitis with areas of multinucleated foreign-body giant cells and accumulation of numerous metal particles but no acute inflammatory response. Six months after the revision THA, the patient has experienced favourable outcomes. This case provides an instructive illustration for studying the consequences of substantial release of Ti-alloy debris from orthopaedic implants.
Purpose: Ablation procedures are common and standard therapeutic interventions for symptomatic patients with persistent atrial fibrillation (AF). Various complications have been observed after the procedure, with one of the most fatal being atrio-esophageal fistula (AEF). Although rare, AEF has very high morality. Diagnosis of AEF is challenging, especially in emergency settings, because of its unspecific clinical signs, such as atypical neurological signs after food or air embolism. Case Presentation: A 46-year-old woman with a 10-year history of AF underwent ethanol infusion of the Marshall vein. Almost a month after the procedure, the patient collapsed and was brought to the emergency department with signs of right side hemiparesis. Occlusion of the left middle cerebral artery was identified with no ischemic change in brain parenchyma. During thrombectomy the patient had a sudden episode of hematemesis. After esophagogastroscopy, she was immediately transferred to the operating room for emergency surgery, but died on the operating table. Autopsy confirmed a clinical suspicion of AEF with massive gastrointestinal bleeding and systemic food embolism. We present this case to improve clinical recognition of the signs of AEF after alcohol ablation for AF. We also recommend active surveillance for patients who undergo similar procedures, including regular check-ups.