Javier S. Zurdo

Mr. Javier S. Zurdo

Arquitectura y Tecnología de Computadores, Rey Juan Carlos University, Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MPMar Pelayo
Mar Pelayo
IPIrene Pelayo-Delgado
Irene Pelayo-Delgado
JSJAVIER SANCHO SAUCO
JAVIER SANCHO SAUCO
Javier S. ZurdoJavier S. Zurdo
Javier S. Zurdo
LALeopoldo Abarca-Martinez
Leopoldo Abarca-Martinez
JAJuan Luis Alcazar
Juan Luis Alcazar
Subjective ultrasound assessment by an expert examiner is meant to be the best option for the differentiation between benign and malignant adnexal masses. Different ultrasound scores can help in the classification, but whether one of them is significantly better than others is still a matter of debate. The main aim of this work is to compare the diagnostic performance of some of these scores in the evaluation of adnexal masses in the same set of patients. This is a retrospective study of a consecutive series of women diagnosed as having a persistent adnexal mass and managed surgically. Ultrasound characteristics were analyzed according to IOTA criteria. Masses were classified according to the subjective impression of the sonographer and other ultrasound scores (IOTA simple rules -SR-, IOTA simple rules risk assessment -SRRA-, O-RADS classification, and ADNEX model -with and without CA125 value-). A total of 122 women were included. Sixty-two women were postmenopausal (50.8%). Eighty-one women had a benign mass (66.4%), and 41 (33.6%) had a malignant tumor. The sensitivity of subjective assessment, IOTA SR, IOTA SRRA, and ADNEX model with or without CA125 and O-RADS was 87.8%, 66.7%, 78.1%, 95.1%, 87.8%, and 90.2%, respectively. The specificity for these approaches was 69.1%, 89.2%, 72.8%, 74.1%, 67.9%, and 60.5%, respectively. All methods with similar AUC (0.81, 0.78, 0.80, 0.88, 0.84, and 0.75, respectively). We concluded that IOTA SR, IOTA SRRA, and ADNEX models with or without CA125 and O-RADS can help in the differentiation of benign and malignant masses, and their performance is similar to the subjective assessment of an experienced sonographer.

23 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MPMar Pelayo
Mar Pelayo
JSJAVIER SANCHO SAUCO
JAVIER SANCHO SAUCO
Javier S. ZurdoJavier S. Zurdo
Javier S. Zurdo
LALeopoldo Abarca-Martinez
Leopoldo Abarca-Martinez
CBCarlota Borrero-Gonzalez
Carlota Borrero-Gonzalez
IPIrene Pelayo-Delgado
Irene Pelayo-Delgado
Background: Several ultrasound (US) features help ultrasound experts in the classification of benign vs. malignant adnexal masses. US scores serve in this differentiation, but they all have misdiagnoses. The main objective of this study is to evaluate what ultrasound characteristics are associated with malignancy influencing ultrasound scores. Methods: This is a retrospective analysis of ultrasound features of adnexal lesions of women managed surgically. Ultrasound characteristics were analyzed, and masses were classified by subjective assessment of the ultrasonographer (SA) and other ultrasound scores (IOTA Simple Rules Risk Assessment SRRA, ADNEX model, and O-RADS). Results: Of a total of 187 adnexal masses studied, 134 were benign (71.7%) and 53 were malignant (28.3%). SA, IOTA SRRA, ADNEX model with or without CA125 and O-RADS had high levels of sensitivity (93.9%, 81.1%, 94.3%, 88.7%, 98.1%) but lower specificity (80.2%, 82.1%, 82.8%, 77.6%, 73.1%) with similar AUC (0.87, 0.87, 0.92, 0.90, 0.86). Ultrasound features significantly related with malignancy were the presence of irregular contour, absence of acoustic shadowing, vascularized solid areas, ≥1 papillae, vascularized septum, and moderate-severe ascites. Conclusion: IOTA SRRA, ADNEX model, and O-RADS can help in the classification of benign and malignant masses. Certain ultrasound characteristics studied in ultrasound scores are associated with malignancy.

28 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MPMar Pelayo
Mar Pelayo
JSJAVIER SANCHO SAUCO
JAVIER SANCHO SAUCO
Javier S. ZurdoJavier S. Zurdo
Javier S. Zurdo
BPBelén Pérez-Mies
Belén Pérez-Mies
LALeopoldo Abarca-Martínez
Leopoldo Abarca-Martínez
IPIrene Pelayo-Delgado
Irene Pelayo-Delgado
Background: Ultrasound features help to differentiate benign from malignant masses, and some of them are included in the ultrasound (US) scores. The main aim of this work is to describe the ultrasound features of certain adnexal masses of difficult classification and to analyse them according to the most frequently used US scores. Methods: Retrospective studies of adnexal lesions are difficult to classify by US scores in women undergoing surgery. Ultrasound characteristics were analysed, and masses were classified according to the Subjective Assessment of the ultrasonographer (SA) and other US scores (IOTA Simple Rules Risk Assessment-SRRA, ADNEX model with and without CA125 and O-RADS). Results: A total of 133 adnexal masses were studied (benign: 66.2%, n:88; malignant: 33.8%, n:45) in a sample of women with mean age 56.5 ± 7.8 years. Malignant lesions were identified by SA in all cases. Borderline ovarian tumors (n:13) were not always detected by some US scores (SRRA: 76.9%, ADNEX model without and with CA125: 76.9% and 84.6%) nor were serous carcinoma (n:19) (SRRA: 89.5%), clear cell carcinoma (n:9) (SRRA: 66.7%) or endometrioid carcinoma (n:4) (ADNEX model without CA125: 75.0%). While most teratomas and serous cystadenomas have been correctly differentiated, other benign lesions were misclassified because of the presence of solid areas or papillae. Fibromas (n:13) were better identified by SA (23.1% malignancy), but worse with the other US scores (SRRA: 69.2%, ADNEX model without and with CA125: 84.6% and 69.2%, O-RADS: 53.8%). Cystoadenofibromas (n:10) were difficult to distinguish from malignant masses via all scores except SRRA (SA: 70.0%, SRRA: 20.0%, ADNEX model without and with CA125: 60.0% and 50.0%, O-RADS: 90.0%). Mucinous cystadenomas (n:12) were misdiagnosed as malignant in more than 15% of the cases in all US scores (SA: 33.3%, SRRA: 16.7%, ADNEX model without and with CA125: 16.7% and 16.7%, O-RADS:41.7%). Brenner tumors are also difficult to classify using all scores. Conclusion: Some malignant masses (borderline ovarian tumors, serous carcinoma, clear cell carcinoma, endometrioid carcinomas) are not always detected by US scores. Fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present solid components/papillae that may induce confusion with malignant lesions. Most teratomas and serous cystadenomas are usually correctly classified.

23 December 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Javier S. ZurdoJavier S. Zurdo
Javier S. Zurdo
JLJosé San Martín López
José San Martín López
The number of vulnerabilities identified annually has increased substantially, thereby raising the risks associated with online services. The implementation of cybersecurity management measures in accordance with the European NIS2 Directive is optional at the local authority level. This study analyzes the external perimeter of nearly 7000 municipalities and proposes a simplified security framework that provides a comprehensive view of security across regions. A complete data set was assembled on the Technological and Competence profiles of all municipalities in Spain over a two-year period. The data were gathered from the external perimeter in relation to security, availability and SEO posture areas. A survey was conducted to determine the level of concern among citizens regarding cybersecurity issues in online municipal services, with 188 respondents. Some regions were identified as exhibiting particularly high and homogeneous levels of security. In contrast, other regions were found to be below the expected level. The presence of supra-local entities, such as the “Diputaciones”, has been demonstrated to facilitate the harmonization of regional security, while simultaneously reducing technological fragmentation and operational expenditure.

28 September 2025 in Electronics
Verified
Journal Article
Open access
PDF file
Javier S. ZurdoJavier S. Zurdo
Javier S. Zurdo
JLJosé San Martín López
José San Martín López
Due to their vast number and heterogeneity, local public administrations can act as entry points (or attack surfaces) for adversaries targeting national infrastructure. The individual vulnerabilities of these entities function as entry points that can be exploited to compromise higher-level government assets. This study presents a nationwide risk analysis of the exposed perimeter of 7000 municipalities, achieved through the massive collection of 93 technological and contextual variables over three consecutive years and the application of supervised machine learning algorithms. The findings of this study demonstrate that geographical factors are a key predictor of external perimeter cyber risk, suggesting that supra-local entities providing unified, shared security services are better positioned in terms of risk exposure and therefore more resilient. Furthermore, the analysis confirms, contrary to conventional wisdom, that IT budget allocation lacks a significant statistical correlation with external perimeter risk mitigation. It is concluded that large-scale data collection frameworks, enhanced by Artificial Intelligence, provide policymakers with an objective and transparent tool to optimize cybersecurity investments and protection strategies.