Jeremy Dahl

Dr. Jeremy Dahl


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2008 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
MPM.L. Palmeri
M.L. Palmeri
MWM.H. Wang
M.H. Wang
JDJeremy Dahl
Jeremy Dahl
KFK.D. Frinkley
K.D. Frinkley
KNK.R. Nightingale
K.R. Nightingale

14 July 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MBMuyinatu A. Lediju Bell
Muyinatu A. Lediju Bell
GTGregg E. Trahey
Gregg E. Trahey
BBBrett C. Byram
Brett C. Byram
JDJeremy Dahl
Jeremy Dahl
Conventional ultrasound images are formed by delay-and-sum beamforming of the backscattered echoes received by individual elements of the transducer aperture. Although the delay-and-sum beamformer is well suited for ultrasound image formation, it is corrupted by speckle noise and challenged by acoustic clutter and phase aberration. We propose an alternative method of imaging utilizing the short-lag spatial coherence (SLSC) of the backscattered echoes. Compared with matched B-mode images, SLSC images demonstrate superior SNR and contrast-to-noise ratio in simulated and experimental speckle-generating phantom targets, but are shown to be challenged by limited point target conspicuity. Matched B-mode and SLSC images of a human thyroid are presented. The challenges and opportunities of real-time implementation of SLSC imaging are discussed.

19 June 2006 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
GPG.F. Pinton
G.F. Pinton
JDJeremy Dahl
Jeremy Dahl
GTG.E. Trahey
G.E. Trahey
Time-delay estimators, such as normalized cross correlation and phase-shift estimation, form the computational basis for elastography, blood flow measurements, and acoustic radiation force impulse (ARFI) imaging. This paper examines the performance of these algorithms for small displacements (less than half the ultrasound pulse wavelength). The effects of noise, bandwidth, stationary echoes, kernel size, downsampling, interpolation, and quadrature demodulation on the accuracy of the time delay estimates are measured in terms of bias and jitter. Particular attention is given to the accuracy and resolution of the displacement measurements and to the computational efficiency of the algorithms. In most cases, Loupas' two-dimensional (2-D) autocorrelator performs as well as the gold standard, normalized cross correlation. However, Loupas' algorithm's calculation time is significantly faster, and it is particularly suited to operate on the signal data format most commonly used in ultrasound scanners. These results are used to implement a real-time ARFI imaging system using a commercial ultrasound scanner and a computer cluster. Images processed with the algorithms are examined in an ex vivo liver ablation study.

21 April 2009 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
GPGianmarco F. Pinton
Gianmarco F. Pinton
JDJeremy Dahl
Jeremy Dahl
SRStephen Rosenzweig
Stephen Rosenzweig
GTGregg E. Trahey
Gregg E. Trahey
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain (FDTD). Three-dimensional solutions of the equation are verified with water tank measurements of a commercial diagnostic ultrasound transducer and are shown to be in excellent agreement in terms of the fundamental and harmonic acoustic fields and the power spectrum at the focus. The linear and nonlinear components of the algorithm are also verified independently. In the linear nonattenuating regime solutions match results from Field II, a well established software package used in transducer modeling, to within 0.3 dB. Nonlinear plane wave propagation is shown to closely match results from the Galerkin method up to 4 times the fundamental frequency. In addition to thermoviscous attenuation we present a numerical solution of the relaxation attenuation laws that allows modeling of arbitrary frequency dependent attenuation, such as that observed in tissue. A perfectly matched layer (PML) is implemented at the boundaries with a numerical implementation that allows the PML to be used with high-order discretizations. A -78 dB reduction in the reflected amplitude is demonstrated. The numerical algorithm is used to simulate a diagnostic ultrasound pulse propagating through a histologically measured representation of human abdominal wall with spatial variation in the speed of sound, attenuation, nonlinearity, and density. An ultrasound image is created in silico using the same physical and algorithmic process used in an ultrasound scanner: a series of pulses are transmitted through heterogeneous scattering tissue and the received echoes are used in a delay-and-sum beam-forming algorithm to generate a images. The resulting harmonic image exhibits characteristic improvement in lesion boundary definition and contrast when compared with the fundamental image. We demonstrate a mechanism of harmonic image quality improvement by showing that the harmonic point spread function is less sensitive to reverberation clutter.

8 March 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DHDongwoon Hyun
Dongwoon Hyun
LBLeandra L. Brickson
Leandra L. Brickson
KLKevin T. Looby
Kevin T. Looby
JDJeremy Dahl
Jeremy Dahl
With traditional beamforming methods, ultrasound B-mode images contain speckle noise caused by the random interference of subresolution scatterers. In this paper, we present a framework for using neural networks to beamform ultrasound channel signals into speckle-reduced B-mode images. We introduce log-domain normalization-independent loss functions that are appropriate for ultrasound imaging. A fully convolutional neural network was trained with simulated channel signals that were co-registered spatially to ground truth maps of echogenicity. Networks were designed to accept 16 beamformed subaperture radiofrequency signals. Training performance was compared as a function of training objective, network depth, and network width. The networks were then evaluated on simulation, phantom, and in vivo data and compared against existing speckle reduction techniques. The most effective configuration was found to be the deepest (16 layer) and widest (32 filter) networks, trained to minimize a normalization-independent mixture of the ℓ1 and multi-scale structural similarity losses. The neural network significantly outperformed delay-and-sum and receive-only spatial compounding in speckle reduction while preserving resolution and exhibited improved detail preservation over a non-local means methods. This work demonstrates that ultrasound B-mode image reconstruction using machine-learned neural networks is feasible and establishes that networks trained solely in silico can be generalized to real-world imaging in vivo to produce images with significantly reduced speckle.

15 April 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
GPGianmarco F Pinton
Gianmarco F Pinton
GTGregg E Trahey
Gregg E Trahey
JDJeremy Dahl
Jeremy Dahl
A full-wave equation that describes nonlinear propagation in a heterogeneous attenuating medium is solved numerically with finite differences in the time domain (FDTD). This numerical method is used to simulate propagation of a diagnostic ultrasound pulse through a measured representation of the human abdomen with heterogeneities in speed of sound, attenuation, density, and nonlinearity. Conventional delay-andsum beamforming is used to generate point spread functions (PSF) that display the effects of these heterogeneities. For the particular imaging configuration that is modeled, these PSFs reveal that the primary source of degradation in fundamental imaging is reverberation from near-field structures. Reverberation clutter in the harmonic PSF is 26 dB higher than the fundamental PSF. An artificial medium with uniform velocity but unchanged impedance characteristics indicates that for the fundamental PSF, the primary source of degradation is phase aberration. An ultrasound image is created in silico using the same physical and algorithmic process used in an ultrasound scanner: a series of pulses are transmitted through heterogeneous scattering tissue and the received echoes are used in a delay-and-sum beamforming algorithm to generate images. These beamformed images are compared with images obtained from convolution of the PSF with a scatterer field to demonstrate that a very large portion of the PSF must be used to accurately represent the clutter observed in conventional imaging.