Jun Pu

Jun Pu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
Qiming LiuQiming Liu
Qiming Liu
QLQifan Lu
Qifan Lu
YCYezi Chai
Yezi Chai
ZTZhengyu Tao
Zhengyu Tao
QWQizhen Wu
Qizhen Wu
JPJun Pu
Jun Pu
Purpose: This study aimed to assess the value of radiomic features derived from the myocardium (MYO) and papillary muscle (PM) for left ventricular hypertrophy (LVH) detection and hypertrophic cardiomyopathy (HCM) versus hypertensive heart disease (HHD) differentiation. Methods: There were 345 subjects who underwent cardiovascular magnetic resonance (CMR) examinations that were analyzed. After quality control and manual segmentation, the 3D radiomic features were extracted from the MYO and PM. The data were randomly split into training (70%) and testing (30%) datasets. Feature selection was performed on the training dataset. Five machine learning models were evaluated using the MYO, PM, and MYO+PM features in the detection and differentiation tasks. The optimal differentiation model was further evaluated using CMR parameters and combined features. Results: Six features were selected for the MYO, PM, and MYO+PM groups. The support vector machine models performed best in both the detection and differentiation tasks. For LVH detection, the highest area under the curve (AUC) was 0.966 in the MYO group. For HCM vs. HHD differentiation, the best AUC was 0.935 in the MYO+PM group. Comparing the radiomics models to the CMR parameter models for the differentiation tasks, the radiomics models achieved significantly improved the performance (p = 0.002). Conclusions: The radiomics model with the MYO+PM features showed similar performance to the models developed from the MYO features in the detection task, but outperformed the models developed from the MYO or PM features in the differentiation task. In addition, the radiomic models performed better than the CMR parameters’ models.

1 July 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Qiming LiuQiming Liu
Qiming Liu
QLQifan Lu
Qifan Lu
YCYezi Chai
Yezi Chai
ZTZhengyu Tao
Zhengyu Tao
QWQizhen Wu
Qizhen Wu
JPJun Pu
Jun Pu
Purpose: In the past decade, there has been a rapid increase in the development of automatic cardiac segmentation methods. However, the automatic quality control (QC) of these segmentation methods has received less attention. This study aims to address this gap by developing an automatic pipeline that incorporates DL-based cardiac segmentation and radiomics-based quality control. Methods: In the DL-based localization and segmentation part, the entire heart was first located and cropped. Then, the cropped images were further utilized for the segmentation of the right ventricle cavity (RVC), myocardium (MYO), and left ventricle cavity (LVC). As for the radiomics-based QC part, a training radiomics dataset was created with segmentation tasks of various quality. This dataset was used for feature extraction, selection, and QC model development. The model performance was then evaluated using both internal and external testing datasets. Results: In the internal testing dataset, the segmentation model demonstrated a great performance with a dice similarity coefficient (DSC) of 0.954 for whole heart segmentations. Images were then appropriately cropped to 160 × 160 pixels. The models also performed well for cardiac substructure segmentations. The DSC values were 0.863, 0.872, and 0.940 for RVC, MYO, and LVC for 2D masks and 0.928, 0.886, and 0.962 for RVC, MYO, and LVC for 3D masks with an attention-UNet. After feature selection with the radiomics dataset, we developed a series of models to predict the automatic segmentation quality and its DSC value for the RVC, MYO, and LVC structures. The mean absolute values for our best prediction models were 0.060, 0.032, and 0.021 for 2D segmentations and 0.027, 0.017, and 0.011 for 3D segmentations, respectively. Additionally, the radiomics-based classification models demonstrated a high negative detection rate of >0.85 in all 2D groups. In the external dataset, models showed similar results. Conclusions: We developed a pipeline including cardiac substructure segmentation and QC at both the slice (2D) and subject (3D) levels. Our results demonstrate that the radiomics method possesses great potential for the automatic QC of cardiac segmentation.