Wenbin Guo

Dr. Wenbin Guo

Institute of Engineering Thermophysics, Chinese Academy of Science, Beijing 100190, P. R. China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
ZLZhihua Lin
Zhihua Lin
Zhitao ZuoZhitao Zuo
Zhitao Zuo
WGWenbin Guo
Wenbin Guo
SJSun Jianting
Sun Jianting
QLQi Liang
Qi Liang
HCHaisheng Chen
Haisheng Chen
The impeller backside cavity (IBC) is a unique structure of centrifugal compressor in compressed air energy storage (CAES) systems, which affects the aerodynamic performance of centrifugal compressor, and the angle change of the downstream coupled adjustable vaned diffusers (AVDs) will affect the flow field inside the cavity and compressor performance. This paper relies on the closed test facility of the high-power intercooling compressor to measure static pressure and static temperature at different radii on the static wall of the IBC. The coupling relationship between the IBC and compressor under variable operating conditions is analyzed, and the influence of AVDs on the internal flow in IBC is studied. The results show that static pressure and static temperature rise along the direction of increasing radius, but static temperature drops near the coupling between the impeller outlet and the cavity inlet. Under AVDs’ design angle, static pressure and static temperature at each point, static pressure loss and static temperature loss in the direction of decreasing radius all increase as the flow decreases. Under variable AVDs’ angles, static pressure and static temperature will change differently, and respective loss will also be different.

29 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
JCJixiang Chen
Jixiang Chen
Zhitao ZuoZhitao Zuo
Zhitao Zuo
XZXin Zhou
Xin Zhou
SJSun Jianting
Sun Jianting
JLJingxin Li
Jingxin Li
HCHaisheng Chen
Haisheng Chen
The oblique flow compressor is one of the important components in the compressed air energy storage (CAES) system. The structural shape of the radial inlet chamber (RIC) directly affects the compressor performance, and a reasonable RIC design should achieve the smallest total pressure loss and outlet distortion as much as possible to meet the structural design. To study the influence of splitter blades, 4 RICs equipped with different numbers of splitter blades are designed, and the performance of 4 RICs and the overall performance of the compressor is calculated. The results show that with the increase in the number of splitter blades, the stall margin increases from 6.3% to 13.94%. At the design point, the isentropic efficiency is highest for the RIC with 17 splitter blades, and the pressure ratio is highest for the RIC with 11 splitter blades. Compared with the direct axial intake mode, the uniformity of the relative leakage distribution and the attack angle distribution of the impeller leading edge under 4 radial intake modes are poor. However, with an increase in the number of splitter blades, the uniformity of the relative tip leakage and the attack angle distribution gradually increase. The flow loss of RIC will increase simultaneously, though the uniformity of the outlet aerodynamic parameters distribution improves, and the influence on the downstream component performance gradually weakens. There is an optimal number of splitter blades in RIC, which balances the total pressure loss and distortion coefficient.