Yunxiang Ma

Dr. Yunxiang Ma

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Journal of Structural Engineering
Verified
Journal Article
Closed access
PDF file
YMYunxiang Ma
Yunxiang Ma
Qingli DaiQingli Dai
Qingli Dai
WPWeichiang Pang
Weichiang Pang
The supportive structures of power grids are vital but susceptible to weather-related events, such as extreme wind and icing rain with concurrent wind. The objective of this paper is to assess the reliability of the power grids subjected to high wind and ice accretion. The material and geometry uncertainty and the strength deterioration of poles due to decay are included in probabilistic models considering the bending failure of the poles and tensile failure of the wires. The extreme wind speed and icing accretion thickness are modeled with the Weibull distribution and generalized Pareto distribution, respectively. The fragility and reliability are analyzed with a Monte Carlo simulation for the comparison of two example locations with different hazard conditions. Case studies are implemented with a notional system and the system of Centerville, a fictitious study domain. The results illustrated that the fragility of wires is noteworthy in icing hazard reliability assessment. During icing rain, the concurrent wind speed significantly impacts the reliability of the power grids. The system reliability subjected to wind hazards is more sensitive to pole strength deterioration than in icing scenarios. The presented analysis framework will be beneficial for the design and maintenance of power grids subjected to both wind and icing hazards.

1 April 2021 in Construction and Building Materials
Verified
Journal Article
Closed access
YMYunxiang Ma
Yunxiang Ma
MMMunkaila Musah
Munkaila Musah
RSRuizhe Si
Ruizhe Si
Qingli DaiQingli Dai
Qingli Dai
Xinfeng XieXinfeng Xie
Xinfeng Xie
RRRobert J. Ross
Robert J. Ross

6 March 2024 in Construction and Building Materials
Verified
Journal Article
Closed access
MMMunkaila Musah
Munkaila Musah
YMYunxiang Ma
Yunxiang Ma
XWXiping Wang
Xiping Wang
RRRobert Ross
Robert Ross
RHReza Hosseinpourpia
Reza Hosseinpourpia
Xinfeng XieXinfeng Xie
Xinfeng Xie


14 May 2026 in Buildings
Verified
Journal Article
Open access
PDF file
YMYunxiang Ma
Yunxiang Ma
Qingli DaiQingli Dai
Qingli Dai
DHDa Huang
Da Huang
MLMiaomiao LI
Miaomiao LI
XZXiang Zhao
Xiang Zhao
The post-tensioned cross-laminated timber (CLT) rocking wall is a recently developed resilient CLT lateral force-resisting system with a self-centering feature. The structural responses of the systems with different designs need to be determined and evaluated efficiently to promote the development and standardization of industrial applications. This study developed a computationally efficient, component-assembled numerical model for post-tensioned cross-laminated timber (PT CLT) rocking walls that captures decompression, post-tension self-centering, and energy dissipation within a framework. The single wall model was assembled using nonlinear zero-length springs for the compression at the CLT bottom, truss bar element for the PT tendon, and elastic shell element for the CLT panel deformation. The energy dissipation device, the UFP, was modeled with nonlinear one-dimensional springs between the wall panels in the coupled wall model. The wall models were separately calibrated considering the wall designs of single-panel walls and coupled walls. Both single and coupled wall models predicted the initial stiffness, decompression, yielding, post-yield stiffness, and reloading/unloading stiffness. The residual drift and nonlinear unloading captured with the PT model were also validated with the test data. A two-story platform structure model was established based on the NHERI Tallwood project, assembled with the coupled wall model and CLT slab in shell elements and columns in Euler beam elements. With recorded ground acceleration signals from the test, the platform structure’s peak story displacement and inter-story drift were simulated with less than 30% differences for most cases. Unlike existing detailed contact-based models, the proposed approach balances local damage fidelity and computational efficiency. The validated model provides a framework for evaluating PT CLT wall design parameters considering their influence on full structures.

19 March 2026 in Buildings
Verified
Journal Article
Open access
PDF file
YMYunxiang Ma
Yunxiang Ma
Qingli DaiQingli Dai
Qingli Dai
XZXiang Zhao
Xiang Zhao
Because of concentrated connection damage, the impact of sequential hazards on CLT shear wall systems is much more severe than that on traditional concrete and steel structures considering ductile component behaviors. The present paper evaluated the dynamic response of CLT wall structures in wind-only and sequential seismic–wind scenarios and compared the structural dynamic responses and damage levels of different CLT wall systems. The structural models were established separately based on an SOM benchmark structure, a SOFIE project three-story CLT shear wall structure, and a PT CLT wall platform structure from the NHERI Tall Wood project. The equivalent fluctuating wind load was calculated with the ASCE 7 average wind speed, the reference ESDU wind profile, calibrated wind pressure distribution, and simulated fluctuation from the NatHaz Online Wind Simulator. The sequential load was applied to the structural models in the order of seismic excitation, resting time, and then dynamic wind load. The dynamic responses of different CLT wall structures were compared among loading scenarios with increasing seismic and wind intensities. The wind-excited peak story displacement and acceleration for both CLT structures were significantly magnified in the sequential seismic–wind scenarios compared with the wind-only scenarios. The simulation results indicated that the sequential seismic–wind scenarios caused significant acceleration in damaged connections for the conventional CLT shear wall structure. The PT CLT wall structure had minor displacement and acceleration, which were linear to the wind loading factors. For the conventional CLT shear wall structure, the magnification of the acceleration was found to have a strong correlation with the natural frequencies of the damaged structure. This study demonstrated that the wind responses of the PT wall structures were in a safe range after the seismic event, and conventional CLT wall structures need to be re-evaluated under sequential scenarios for structural resilience assessment.