Taoning Guo

Mr. Taoning Guo

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XLXiaohu Liu
Xiaohu Liu
WHWei He
Wei He
Pan GuoPan Guo
Pan Guo
YYYuhang Yang
Yuhang Yang
TGTaoning Guo
Taoning Guo
ZXZheng Xu
Zheng Xu
This article presents a semi-contactless power measurement method aimed at offering power measurements of residential homes, which are power supplied by the single-phase two-wire entrance lines, for studying the nonintrusive load monitoring (NILM) technique. The active power is calculated using the waveforms of the line current and voltage. To measure the line current, a magnetic sensor array consisting of seven tunnel magnetoresistance (TMR) sensors is utilized to detect the magnetic fields around the entrance lines. The single-phase time-domain current is then reversely calculated on real time by matrix multiplication using the time-domain output signals of the TMR sensor array once the entrance line positions are identified through solving the formulated nonlinear least square (NLLS) problem. In terms of the line voltage, a capacitively coupling voltage sensor is proposed to achieve almost in-phase tracking with the line voltage waveform. The voltage ratio of the voltage senor is calibrated using the measured rms value of line voltage from the outlet sockets or power strips in situ by a multimeter (thus called semi-contactless) due to the main disadvantage for capacitively coupling voltage sensing. That is, accuracy in voltage amplitude measurement is low because of the great difficulty in accurately determining the coupling capacitances. Numerical integration method for calculating the active power based on quasi-synchronous algorithm is proposed to eliminate the errors caused by the noninteger period sampling. Prototype instrument is designed and fabricated. Frequency response characterization shows that the TMR sensor (voltage sensor) has an almost constant gain factor (voltage ratio) and an approximate zero-phase shift (<1°) over a frequency range of $50-3.05$ kHz. Laboratory tests for both fundamental current phasor and active power measurement along with their measurement uncertainty evaluations are first conducted to verify the feasibility of the proposed method. Field tests in a residential home are subsequently performed to further demonstrate the effectiveness of the proposed method. A power measurement error of less than 5% can be obtained, which is sufficient for home energy tracking.

11 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TGTaoning Guo
Taoning Guo
WHWei He
Wei He
CWCai Wan
Cai Wan
YZYuxiang Zhang
Yuxiang Zhang
ZXZheng Xu
Zheng Xu
Nuclear magnetic resonance (NMR) magnetometers are considered due to their ability to map magnetic fields with high precision and calibrate other magnetic field measurement devices. However, the low signal-to-noise ratio of low-strength magnetic fields limits the precision when measuring magnetic fields below 40 mT. Therefore, we developed a new NMR magnetometer that combines the dynamic nuclear polarization (DNP) technique with pulsed NMR. The dynamic pre-polarization technique enhances the SNR under a low magnetic field. Pulsed NMR was used in conjunction with DNP to improve measurement accuracy and speed. The efficacy of this approach was validated through simulation and analysis of the measurement process. Next, a complete set of equipment was constructed, and we successfully measured magnetic fields of 30 mT and 8 mT with an accuracy of only 0.5 Hz (11 nT) at 30 mT (0.4 ppm) and 1 Hz (22 nT) at 8mT (3 ppm).