Piezoresistive pressure sensors exhibit inherent nonlinearity and sensitivity to ambient temperature, requiring multidimensional compensation to achieve accurate measurements. However, recent studies on software compensation mainly focused on developing advanced and intricate algorithms while neglecting the importance of calibration data and the limitation of computing resources. This paper aims to present a novel compensation method which generates more data by learning the calibration process of pressure sensors and uses a larger dataset instead of more complex models to improve the compensation effect. This method is performed by the proposed aquila optimizer optimized mixed polynomial kernel extreme learning machine (AO-MPKELM) algorithm. We conducted a detailed calibration experiment to assess the quality of the generated data and evaluate the performance of the proposed method through ablation analysis. The results demonstrate a high level of consistency between the generated and real data, with a maximum voltage deviation of only 0.71 millivolts. When using a bilinear interpolation algorithm for compensation, extra generated data can help reduce measurement errors by 78.95%, ultimately achieving 0.03% full-scale (FS) accuracy. These findings prove the proposed method is valid for high-accuracy measurements and has superior engineering applicability.
The complex and time-varying external climate conditions and multi-equipment variable coupling characteristics make it challenging to optimize the Heating, Ventilation, and Air Conditioning (HVAC) systems in existing buildings effectively. Additionally, the intricate energy exchange processes within HVAC systems present difficulties in developing accurate and generalizable energy consumption models. In response to these challenges, this paper proposes an Ant Lion Optimizer with Enhancements (ALOE) that can dynamically adjust the number of populations and the movement trend to improve the convergence speed and optimization ability, and randomly adjust the movement amplitude to enhance the local optimal escape ability. Finally, a case study of an office building in Hangzhou was carried out, and an overall energy consumption model of the HVAC system based on parameter identification and a general mechanism model was established. In this model, the energy-saving optimization effects of various advanced swarm intelligence optimization algorithms were compared. The experimental results demonstrate that under high, medium, and low load conditions, the ALOE algorithm achieves energy-saving rates of 28.16%, 28.26%, and 24.85%, respectively, the overall energy-saving rate for the entire day reaches 29.06%, which indicates the ALOE has significant superiority. This work will contribute to the development of energy-saving and emission-reduction technologies.