The flow pattern in a pumping station intake basin has a significant influence on the inlet conditions of the pumping machine. For the purpose of solving the problems of flow disorder and the uneven flow velocity distribution in the intake basin of a lateral-inlet pumping station with a truncated-type canal, this study takes a flood discharge pumping station as an example and then studies and analyzes the flow pattern in the inlet pool of a lateral-inlet pumping station with a truncated-type canal. The Revit2018 modeling software is used to establish a three-dimensional model, CFD fluid calculation software is used to simulate the fluid, and the reliability of the numerical simulation results is verified using physical model tests. This paper proposes a new type of separated guide wall rectification measure, which is combined with a guide pier and other optimization measures to improve the flow of the inlet pool and is composed of a variety of programs. The results show that the optimization scheme of a “closed flow guide wall and flow guide pier” is the most effective. Compared with the original scheme, the lateral flow velocity distribution ratio and the mean square error (MSE) are reduced, while the axial flow velocity uniformity is increased by 52.24% and the axial flow velocity weighted average angle is increased by 5.92°. The optimal spacing of the dividing deflector wall is investigated using the response surface methodology, and further optimization of the scheme results in a further increase of 2.23% in the flow uniformity.
The outlet pressure box culvert is often used as the drainage building of a pumping station. Because of its compact structure, it produces transverse flow velocity and then forms poor flow patterns, such as bias flow, reflux, and flow separation, which affect the discharge efficiency of the pumping station. Based on the combination of a physical model test and numerical simulation, the hydraulic characteristics of an eccentric tapering outlet pressure box culvert were analyzed. Focusing on the poor flow pattern in the box culvert, different optimization schemes were proposed to adjust the flow pattern. The flow pattern, transverse velocity distribution ratio (which represents the proportion of transverse velocity in velocity), average angle of the axial velocity, axial velocity uniformity, and pressure distribution of each scheme were compared to obtain the best scheme. The results show that the combination scheme of “diversion pier position and angle with deflecting flow baseplate” has the best optimization effect on the flow pattern. This scheme can effectively improve the bad flow pattern, significantly reduce the transverse velocity distribution ratio, and make the pressure distribution on both sides of the long diversion pier uniform. The axial velocity uniformity was increased by 17.45%, and the average angle of the axial velocity was increased by 8.23°.