Yi Lin

Yi Lin


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

3 September 2022 in BMC Cancer
Verified
Journal Article
Open access
PDF file
YMYanqing Ma
Yanqing Ma
JLJie Li
Jie Li
XXXiren Xu
Xiren Xu
YZYang Zhang
Yang Zhang
YLYi Lin
Yi Lin
Object: To evaluate the difference between multiple primary lung adenocarcinoma (MPLA) and solitary primary lung adenocarcinoma (SPLA) by delta-radiomics based machine learning algorithms in CT images. Methods: A total of 1094 patients containing 268 MPLAs and 826 SPLAs were recruited for this retrospective study between 2014 to 2020. After the segmentation of volume of interest, the radiomic features were automatically calculated. The patients were categorized into the training set and testing set by a random proportion of 7:3. After feature selection, the relevant classifiers were constructed by the machine learning algorithms of Bayes, forest, k-nearest neighbor, logistic regression, support vector machine, and decision tree. The relative standard deviation (RSD) was calculated and the classification model with minimal RSD was chosen for delta-radiomics analysis to explore the variation of tumor during follow-up surveillance in the cohort of 225 MPLAs and 320 SPLAs. According to the different follow-up duration, it was divided into group A (3–12 months), group B (13–24 months), and group C (25–48 months). Then the corresponding delta-radiomics classifiers were developed to predict MPLAs. The area under the receiver operator characteristic curve (AUC) with 95% confidence interval (CI) was quantified to evaluate the efficiency of the model. Results: To radiomics analysis, the forest classifier (FC-radio) with the minimal RSD showed the better stability with AUCs of 0.840 (95%CI, 0.810–0.867) and 0.670 (95%CI, 0.611–0.724) in the training and testing set. The AUCs of the forest classifier based on delta-radiomics (FC-delta) were higher than those of FC-radio. In addition, with the extension of follow-up duration, the performance of FC-delta in Group C were the best with AUCs of 0.998 (95%CI, 0.993–1.000) in the training set and 0.853 (95%CI, 0.752–0.940) in the testing set. Conclusions: The machine-learning approach based on radiomics and delta-radiomics helped to differentiate SPLAs from MPLAs. The FC-delta with a longer follow-up duration could better distinguish between SPLAs and MPLAs.

7 February 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YMYanqing Ma
Yanqing Ma
HCHanbo Cao
Hanbo Cao
JLJie Li
Jie Li
MLMu Lin
Mu Lin
XGXiangyang Gong
Xiangyang Gong
YLYi Lin
Yi Lin
Small-field-of-view reconstruction CT images (sFOV-CT) increase the pixel density across airway structures and reduce partial volume effects. Multi-instance learning (MIL) is proposed as a weakly supervised machine learning method, which can automatically assess the image quality. The aim of this study was to evaluate the disparities between conventional CT (c-CT) and sFOV-CT images using a lung nodule system based on MIL and assessments from radiologists. 112 patients who underwent chest CT were retrospectively enrolled in this study between July 2021 to March 2022. After undergoing c-CT examinations, sFOV-CT images with small-field-of-view were reconstructed. Two radiologists analyzed all c-CT and sFOV-CT images, including features such as location, nodule type, size, CT values, and shape signs. Then, an MIL-based lung nodule system objectively analyzed the c-CT (c-MIL) and sFOV-CT (sFOV-MIL) to explore their differences. The signal-to-noise ratio of lungs (SNR-lung) and contrast-to-noise ratio of nodules (CNR-nodule) were calculated to evaluate the quality of CT images from another perspective. The subjective evaluation by radiologists showed that feature of minimal CT value (p = 0.019) had statistical significance between c-CT and sFOV-CT. However, most features (all with p < 0.05), except for nodule type, location, volume, mean CT value, and vacuole sign (p = 0.056–1.000), had statistical differences between c-MIL and sFOV-MIL by MIL system. The SNR-lung between c-CT and sFOV-CT had no statistical significance, while the CNR-nodule showed statistical difference (p = 0.007), and the CNR of sFOV-CT was higher than that of c-CT. In detecting the difference between c-CT and sFOV-CT, features extracted by the MIL system had more statistical differences than those evaluated by radiologists. The image quality of those two CT images was different, and the CNR-nodule of sFOV-CT was higher than that of c-CT.

17 June 2022 in Research Square
Verified
Preprint
Open access
PDF file
YMYanqing Ma
Yanqing Ma
JLJie Li
Jie Li
XXXiren Xu
Xiren Xu
YZYang Zhang
Yang Zhang
YLYi Lin
Yi Lin
Object: To evaluate the difference between multiple primary lung carcinoma (MPLC) and solitary primary lung carcinoma (SPLC) by delta-radiomics based machine learning algorithms in CT images. Methods A cohort of 1094 patients containing 268 MPLCs and 826 SPLCs were enrolled for radiomic study. After the segmentation of volume of interest, the radiomic features were automatically calculated. The patients were divided into the training set and validation set with a random proportion of 7:3. After the methods of feature selection, the relevant classifiers were constructed by the machine learning algorithms of Bayes, forest, k-nearest neighbor, logistic regression, support vector machine, and decision tree. The relative standard deviation (RSD) was calculated and the classification model with minimal RSD was chosen for delta-radiomics analysis to explore the variation of tumor during follow-up surveillance in the cohort of 225 MPLCs and 320 SPLCs. According to the different follow-up duration, three groups were divided into group A (3–12 months), group B (13–24 months), and group C (25–48 months). Then the corresponding delta-radiomics classifiers were developed to evaluate MPLCs. The area under the receiver operator characteristic curve (AUC) with 95% confidence interval (CI) was quantified to evaluate the efficiency of the model. Results To radiomics analysis, the forest classifier (FC-radio) with the minimal RSD showed the better stability was chosen with AUCs of 0.840 (95%CI, 0.810–0.867) and 0.670 (95%CI, 0.611–0.724) in the training and validation set. The AUCs of the forest classifier based on delta-radiomics (FC-delta) were higher than those of FC-radio. In addition, with the extension of follow-up duration, the performance of FC-delta in Group C were the best with AUCs of 0.998 (95%CI, 0.993-1.000) in the training set and 0.853 (95%CI, 0.752–0.940) in the validation set. Conclusions The machine-learning approach based on radiomics and delta-radiomics helped to differentiate SPLCs from MPLCs. The FC-delta with longer follow-up duration better differentiated SPLCs from MPLCs.

22 July 2022 in Research Square
Verified
Preprint
Open access
PDF file
YMYanqing Ma
Yanqing Ma
HCHanbo Cao
Hanbo Cao
JLJie Li
Jie Li
MLMu Lin
Mu Lin
XGXiangyang Gong
Xiangyang Gong
YLYi Lin
Yi Lin
Background To subjectively and objectively assess the performance of conventional CT (c-CT) and small-field-of-view reconstruction CT (sFOV-CT) by radiologists and a multi-instance learning (MIL) based lung nodule system. Methods A cohort of 112 patients were enrolled between July 2021 to March 2022 in this prospective study. After taking c-CT examinations, the sFOV-CT images with small-field-of-view were reconstructed. All the c-CT and sFOV-CT images were subjectively analyzed by two radiologists, including features of location, nodule type, size, CT values, and shape sign. Then a lung nodule system based on MIL objectively analyzed the c-CT (c-MIL) and sFOV-CT (sFOV-MIL) to explore their difference. Additionally, the signal-to-noise ratio of lung (SNR-lung) and contrast-to-noise ratio of nodule(CNR-nodule) were calculated to evaluate the quality of CT images. Results The subjective evaluation by two radiologists showed that only the features of minimal CT value (p = 0.019) had statistical significance between c-CT and sFOV-CT. While, to the objective analysis by MIL system, the most features (all the p < 0.05) except for nodule type, location, volume, mean CT value, and vacuole sign (p = 0.056-1.000) had statistical difference between c-MIL and sFOV-MIL. The SNR-lung between c-CT and sFOV-CT had no statistical significance, while the CNR-nodule showed statistical difference (p = 0.007) and the CNR of sFOV-CT was higher than that of c-CT (median, inter-quartile: 2.203, 1.620–2.793 vs. 1.850, 1.027–2.558). Conclusions The MIL system were more sensitive than radiologists’ subjective evaluation in detecting the difference between c-CT and sFOV-CT. The image quality of those two CT images were different, and the CNR-nodule of sFOV-CT was higher than that of c-CT.