Mengwei Niu

Prof. Dr. Mengwei Niu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
YHYao Han
Yao Han
FLFan Li
Fan Li
LYLan Yang
Lan Yang
XGXudong Guo
Xudong Guo
XDXue Dong
Xue Dong
YSYansong Sun
Yansong Sun
The rapid and ongoing spread of the coronavirus disease (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), emphasizes the urgent need for an easy and sensitive virus detection method. Here, we describe an immunocapture magnetic bead-enhanced electrochemical biosensor for ultrasensitive SARS-CoV-2 detection based on clustered regularly interspaced short palindromic repeats (CRISPR) and CRISPR-associated (Cas) proteins, collectively known as CRISPR-Cas13a technology. At the core of the detection process, low-cast and immobilization-free commercial screen-printed carbon electrodes are used to measure the electrochemical signal, while streptavidin-coated immunocapture magnetic beads are used to reduce the background noise signal and enhance detection ability by separating the excessive report RNA, and a combination of isothermal amplification methods in the CRISPR-Cas13a system is used for nucleic acid detection. The results showed that the sensitivity of the biosensor increased by two orders of magnitude when the magnetic beads were used. The proposed biosensor required approximately 1 h of overall processing time and demonstrated an ultrasensitive ability to detect SARS-CoV-2, which could be as low as 1.66 aM. Furthermore, owing to the programmability of the CRISPR-Cas13a system, the biosensor can be flexibly applied to other viruses, providing a new approach for powerful clinical diagnostics.

12 November 2026 in Molecules
Verified
Journal Article
Open access
PDF file
DLDong Li
Dong Li
YLYanting Lu
Yanting Lu
WSWei Shen
Wei Shen
WLWenjun Li
Wenjun Li
MNMengwei Niu
Mengwei Niu
GDGang Dong
Gang Dong
Hendra virus (HeV) is a zoonotic pathogen that can cause severe disease in humans. Because early symptoms are nonspecific and no licensed human vaccine or specific antiviral treatment is available, rapid testing may support timely clinical management. We developed an amplification-free CRISPR-field-effect transistor (CRISPR-FET) assay for HeV RNA. This study reports a novel amplification-free nucleic acid detection platform (CRISPR-FET) that integrates the specific collateral cleavage activity of CRISPR/Cas13a with the sensitive transduction capability of FETs. The CRISPR-FET platform achieves sensitive detection of Hendra virus nucleic acids with a limit of detection as low as 101 copies/μL (Ct value 33.0), eliminating the need for target nucleic acid preamplification and significantly streamlining the diagnostic process. To validate the specificity and reliability of this approach, we conducted cross-reactivity tests using eight RNA viruses with clinically similar symptoms and evaluated detection performance with 26 simulated clinical samples. However, the current study was performed using simulated rather than authentic clinical specimens, and the assay provides qualitative rather than quantitative results. Further validation with a larger number of clinical samples are required before clinical application.