Yun-Sic Bang

Prof. Dr. Yun-Sic Bang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2022 in Journal of Molecular Neuroscience
Verified
Journal Article
Closed access
PDF file
JLJae A. Lee
Jae A. Lee
DBDong Hyuck Bae
Dong Hyuck Bae
WCWoo Hee Choi
Woo Hee Choi
CCChang-Hoon Cho
Chang-Hoon Cho
YBYun-Sic Bang
Yun-Sic Bang
JYJongman Yoo
Jongman Yoo

4 September 2020 in Medicine
Verified
Journal Article
Open access
SPSungchul Park
Sungchul Park
JLJoohyun LEE
Joohyun LEE
HCHyung Rae Cho
Hyung Rae Cho
KKKoeun Kim
Koeun Kim
YBYun-Sic Bang
Yun-Sic Bang
YKYoung Uk Kim
Young Uk Kim
A hypertrophied posterior tibial tendon (PTT) has been considered to be an important morphologic parameter of PTT dysfunction (PTTD). Previous research has demonstrated that the PTT thickness (PTTT) is correlated with early signs of PTTD. However, the thickness is different from hypertrophy. Thus, we devised the PTT cross-sectional area (PTTCSA) as a new predictive parameter for diagnosing the PTTD. The PTT data were acquired from 14 patients with PTTD and from 20 normal individuals who underwent ankle magnetic resonance imaging. We measured the PTTT and PTTCSA at the PTT on the ankle magnetic resonance imaging. The mean PTTT was 2.43 ± 0.39 mm in the normal group and 3.40 ± 0.42 mm in the PTTD group. The average PTTCSA was 16.10 ± 4.27 mm2 in the normal group and 26.93 ± 4.38 mm2 in the PTTD group. The receiver operator characteristic analysis curve demonstrated that the highest predictive value of the PTTT was 3.07 mm, with 85.7% sensitivity, 85.0% specificity. The highest predictive value of the PTTCSA was 22.54 mm 2 , with 92.9% sensitivity, 90.0% specificity. Our findings suggest that the PTTCSA was a more valid predictor of PTTD, even though the PTTT and PTTCSA were both significantly associated with PTTD.

7 May 2019 in Pain Research and Management
Verified
Journal Article
Open access
PDF file
YBYun-Sic Bang
Yun-Sic Bang
JPJunbeom Park
Junbeom Park
SLSun Young Lee
Sun Young Lee
JPJiyeon Park
Jiyeon Park
SPSukhee Park
Sukhee Park
YLYoon-Kyung Lee
Yoon-Kyung Lee
Objective. Thickened inferior glenohumeral ligament (IGHL) is considered as one of the major morphological parameters of adhesive capsulitis (AC). Previous studies reported that the anterior band of inferior glenohumeral ligament thickness (aIGHLT) is correlated with shoulder capsular contracture, luxatio erecta humeri, and AC. However, the thickness varies from the measured angle. To reduce this measurement error, we devised a new morphological parameter, called the anterior band of inferior glenohumeral ligament area (aIGHLA). Methods. The aIGHL samples were collected from 54 patients with AC and from 50 control subjects who underwent shoulder magnetic resonance imaging (MRI) without any evidence of AC. Coronal T2-weighted MRI images were obtained at the shoulder level from each patient. We measured the aIGHLA and aIGHLT at the maximal view of the IGHL in the coronal plane using our picture archiving and communication system. The aIGHLA was measured at the whole cross-sectional area of the IGHL in the most hypertrophied segment of the coronal MR images. The aIGHLT was measured at the thickest point of the IGHL. Results. The average aIGHLA was 55.58 ± 14.16 mm2 in the control group and 83.71 ± 28.45 mm2 in the AC group. The average aIGHLT was 3.47 ± 0.99 mm in the control group and 4.52 ± 1.02 mm in the AC group. AC patients showed significantly greater aIGHLA (p<0.001) and aIGHLT (p<0.001) than control subjects. Receiver operating characteristic (ROC) curve analysis showed that the optimal cut-off score of the aIGHLA was 63.37 mm2, with 79.6% sensitivity, 80.0% specificity, and AUC of 0.84 (95% CI, 0.76–0.92). The optimal cut-off point of the IGHLT was 3.81 mm, with 74.1% sensitivity, 74.0% specificity, and AUC of 0.77 (95% CI, 0.68–0.86). Conclusions. Although the aIGHLA and aIGHLT were both significantly associated with AC, the aIGHLA was a more sensitive diagnostic parameter.

20 October 2023 in Medicine
Verified
Journal Article
Open access
CPChunghyun Park
Chunghyun Park
TKTaeyeon Kim
Taeyeon Kim
SOSoojeong Oh
Soojeong Oh
YBYun-Sic Bang
Yun-Sic Bang
Thermoregulation is important for maintaining homeostasis in the body. It can be easily broken under anesthesia. An appropriate method for measuring core body temperature is needed, especially for elderly patients, because the efficiency of thermoregulation gradually decreases with age. Zero-heat-flux (ZHF) thermometry (SpotOn) is an alternative, noninvasive method for continuous temperature monitoring at the skin surface. The aim of this study was to examine the accuracy and feasibility of using the SpotOn sensor in lower extremity orthopedic surgery in elderly patients aged over 80 years by comparing a SpotOn sensor with 2 other reliable minimally invasive methods: a tympanic membrane thermometer and a bladder thermometer. This study enrolled 45 patients aged over 80 years who were scheduled to undergo lower extremity surgery. Body temperature was measured using a SpotOn sensor, a tympanic membrane thermometer and a bladder thermometer. Agreements between the SpotOn sensor and the other 2 methods were assessed using Bland and Altman plots for repeated measures adjusted for unequal numbers of measurements per patient. Compared with bladder temperature, bias and limits of agreement for SpotOn temperature were 0.07°C ± 0.58°C. Compared with tympanic membrane temperature, bias and limits of agreement for SpotOn temperature were −0.28°C ± 0.61°C. The 3M SpotOn sensor using the ZHF method for patients aged over 80 years undergoing lower extremity surgery showed feasible measurement value and sensitivity.

15 October 2021 in Medicine
Verified
Journal Article
Open access
JYJung-min Yi
Jung-min Yi
HJHye-Won Jeong
Hye-Won Jeong
HCHyung Rae Cho
Hyung Rae Cho
KKKeum Nae Kang
Keum Nae Kang
JLJonghyuk Lee
Jonghyuk Lee
YKYoung Uk Kim
Young Uk Kim
Carpal tunnel syndrome (CTS) is a common neuropathy. Although CTS progression is known to be associated with thenar muscle (TM) atrophy, the diagnostic value of TM atrophy for CTS has not been established. In this research, the thenar muscle cross-sectional area (TMCSA) was evaluated to analyze the relationship between the TMCSA and CTS. We assumed that TMCSA is a major diagnostic parameter in the CTS. Both TMCSA and thenar muscle thickness (TMT) samples were acquired from 18 CTS patients, and from 18 control subjects who underwent wrist magnetic resonance imaging with no evidence of CTS. T2-weighted transverse magnetic resonance imaging images were obtained. We measured the TMCSA and TMT at the level of first carpometacarpal joint. The average TMCSA was 296.98 ± 49.39 mm2 in the normal group and 203.36 ± 72.13 mm2 in the CTS group. The average TMT was 8.54 ± 1.45 mm in the normal group and 7.38 ± 1.14 mm in the CTS group. CTS group had significantly lower TMCSA and TMT. Receiver operator characteristics curve analysis showed that the best cutoff point for the TMCSA was 260.18 mm2, with 77.8% sensitivity, 77.8% specificity. The best cutoff point of the TMT was 7.70 mm, with 61.1% sensitivity, 66.7% specificity. Although the TMCSA and TMT were both significantly associated with CTS, the TMCSA was a much more sensitive measurement parameter. Thus, to evaluate CTS patients, the physician should more carefully inspect the TMCSA than TMT.

7 October 2022 in Medicine
Verified
Journal Article
Open access
YJYoung Joo
Young Joo
JMJee Youn Moon
Jee Youn Moon
YLYoon Jin Lee
Yoon Jin Lee
YBYun-Sic Bang
Yun-Sic Bang
JYJungmin Yi
Jungmin Yi
YKYoung Uk Kim
Young Uk Kim
Carpal tunnel syndrome (CTS) is correlated with increased intracarpal canal pressure (ICP). The effect of palmaris longus tendon (PLT) loading on ICP is documented in previous researches. PLT loading induces the greatest absolute increase in ICP. Therefore, to analyze the connection between the PLT and CTS, we newly made the measurement of the PLT cross-sectional area (PLTCSA). We assumed that PLTCSA is a reliable diagnostic parameter in the CTS. PLTCSA measurement data were acquired from 21 patients with CTS, and from 21 normal subjects who underwent wrist magnetic resonance imaging (W-MRI). We measured the PLTCSA at the level of pisiform on W-MRI. The PLTCSA was measured on the outlining of PLT. The two different cutoff values in the analysis were determined using receiver operating characteristic (ROC) analysis. The mean PLTCSA was 2.34 ± 0.82 mm2 in the normal group and 3.97 ± 1.18 mm2 in the CTS group. ROC curve analysis concluded that the best cutoff point for the PLTCSA was 2.81 mm2, with 76.2% sensitivity, 71.4% specificity, and area under the curve of 0.88 (95% CI, 0.78‐0.98). PLTCSA is a sensitive, new, objective morphological parameter for evaluating CTS.