Earlier the methods adopted for the repair and rehabilitation were the external bonding of the damaged component with steel fibers and steel jackets. But the major problem that caused due to this steel components is corrosion. Fiber Reinforced Polymer (FRP) composite materials used for strengthening of components in the form of confinement is of considerable importance in civil engineering. This paper presents the results of axially loaded RC short columns which are strengthened by providing confinement with new material BFRP. The primary objective of this work is to examine the load carrying capacity of concrete columns confined with basalt fiber reinforced polymer jacket (BFRP) which is considered as an abstruse material for strengthening. BFRP materials are non-corrosive, non-magnetic, and chemical resistant and they are progressively being used for repair, rehabilitation, and strengthening of structures that are not stable enough to carry loads. The parameters considered in the study are full and partial wrapping and the number of layers of confinement. The results obtained from the experimental studies and the analytical models precisely shows that the BFRP confinements will upgrade the compressive strength of columns under the given load condition.
Low-density concretes made with lightweight aggregates are known for their enhanced thermal insulation properties. Though the temperature resistance is better than normal concretes, lightweight aggregate concrete (LWAC) experiences significant structural degradation when subjected to extreme conditions, especially those exceeding temperatures of 400°C. Encompassing the safety and durability of structures, auditing the strength of LWAC subject to elevated temperatures is crucial. The present research aims to analyse the density, strength, and microstructural morphology of expanded clay aggregate concrete when subjected to elevated temperatures, particularly 100°C, 200°C, 400°C, and 800°C. Concrete mixes were prepared with crushed stone aggregates replaced with ECA at 0%, 50%, and 100% by volume. The mixes were then further modified by reinforcing the matrix with hybrid fibres at 1.5% (1% steel and 0.5% polypropylene) by volume. The cured specimens were exposed to elevated temperatures and then tested for their mass and strength properties. Notable mass loss was observed for all the mixes post-thermal exposure, and improvement in strength was observed for the mixes when exposed up to 200°C. Further exposure led to a strength degradation. The observed degradation is potentially connected to the complete disintegration of the microstructure, as seen in the Scanning Electron Microscopy (SEM) images.