Accurate measurement of magnetic fields holds immense significance across various disciplines, such as IC circuit measurement, geological exploration, and aerospace. The sensitivity and noise parameters of magnetic field sensors play a vital role in detecting minute fluctuations in magnetic fields. However, the current detection capability of tunneling magnetoresistance (TMR) is insufficient to meet the requirements for weak magnetic field measurement. This study investigates the impact of structural and fabrication parameters on the performance of TMR sensors. We fabricated series-connected TMR sensors with varying long-axis lengths of the elliptical cross-section and adjusted their performance by modifying annealing magnetic fields and magnetic field bias along the easy axis. The results demonstrate that TMR sensitivity decreases with increasing long-axis length, increases initially and then decreases with an annealing magnetic field, and decreases with a higher bias magnetic field along the easy axis. The voltage noise level of TMR sensors decreases as the long-axis length increases. Notably, the detection capability of TMR sensors exhibits a non-monotonic dependence on long-axis length. Moreover, we optimized the hysteresis of TMR sensors by applying a magnetic field bias along the easy axis. When the bias along the easy axis reached 16 Oe or −40 Oe, the hysteresis level was reduced to below 0.5 Oe. After encapsulating the TMR devices into a full Wheatstone bridge structure, we achieved a detection capability of 17 nT/@1Hz. This study highlights that the detection capability of TMR devices is jointly influenced by fabrication parameters. By optimizing parameter configuration, this work provides theoretical guidance for further enhancing the performance of TMR devices in magnetic field measurements.
Measuring weak magnetic fields proposes significant challenges to the sensing capabilities of magnetic field sensors. The magnetic field detection capacity of tunnel magnetoresistance (TMR) sensors is often insufficient for such applications, necessitating targeted optimization strategies to improve their performance in weak-field measurements. Utilizing magnetic flux concentrators (MFCs) offers an effective approach to enhance TMR sensitivity. In this study, the finite element method was employed to analyze the effects of different MFC geometric structures on the uniformity of the magnetic field in the air gap and the magnetic circuit gain (MCG). It was determined that the MCG of the MFC is not directly related to the absolute values of its parameters but rather to their ratios. Simulation analyses evaluated the impact of these parameter ratios on both the MCG and its spatial distribution uniformity, leading to the formulation of MFC design optimization principles. Building on these simulation-derived principles, several MFCs were fabricated using the 1J85 material, and an experimental platform was established to validate the simulation findings. The fabricated MFCs achieved an MCG of 7.325 times. Based on the previously developed TMR devices, a detection sensitivity of 2.46 nT/ @1Hz was obtained. By optimizing parameter configurations, this work provides theoretical guidance for further enhancing the performance of TMR sensors in magnetic field measurements.