In order to realize the online detection of ARINC bus cable fault, a method of spread spectrum time-domain reflectometry (SSTDR) is proposed in this article, which can minimize the influence between the ARINC bus signal and incident signal, and meet the requirements of aircraft airworthiness. First, the impedance characteristics and reflection characteristics of the aircraft ARINC bus cables are analyzed so that the online detection model based on SSTDR is constructed. Then, the SSTDR incident signal is designed by studying the relationship between the incident signal parameters and the ARINC bus characteristics. Finally, the proposed method is verified through the online detection platform of ARINC 429/825 bus cable fault, and the experimental signals are analyzed in the time domain and the frequency domain, respectively, which indicates that the ARINC bus signal and the incident signal do not interfere with each other. The experimental results prove that the method of SSTDR is effective and feasible to the online detection of ARINC bus cable fault.
20 June 2022 in IEEE Transactions on Aerospace and Electronic Systems
Aviation cables are an essential part of aircraft, which transmits signals and power. Aviation cable faults often occur due to drastic changes in temperature and humidity and the effects of vibration. Obvious cable faults, such as open circuits and short circuits, can be detected during maintenance. However, some soft faults like the loose connection of the connector, damage of the insulation layer, and improper cable bending radius cannot be detected. Spread Spectrum Time Domain Reflectometry (SSTDR) is a diagnostic method for cable faults; however, the amplitude of the reflected signal is low when the soft fault occurs. SSTDR is only sensitive to apparent faults, but it is insufficient to detect soft faults. This paper proposes an aviation cable fault detection and location method, Augmented Spread Spectrum Time Domain Reflectometry (ASSTDR), to detect soft faults effectively. Firstly, the SSTDR results are decomposed into some Intrinsic Mode Functions (IMFs) using the improved Variational Mode Decomposition (VMD) and selects the IMF with the highest kurtosis to analyze. Secondly, Short-time Fourier Transform (STFT) is applied to deal with the selected IMF to enhance the amplitude characteristics. Then, Reassign Spectrogram (RSP) is computed to improve the resolution of STFT time-frequency distribution images to locate the location of soft faults. Finally, the effectiveness of ASSTDR is verified by experiments with different fault types and fault degrees. The comparative experiments demonstrate that the method can accurately detect soft faults.
The widespread use of composite materials with low electrical conductivity in modern advanced aircraft has placed higher requirements on lightning protection for airborne equipment. To ensure the safe operation of aircraft under a lightning environment, the internal cables and cable tracks of composite aircraft are modeled. The lightning protection performance of cables is calculated for different types and shielding parameters, and the effect of the cable layout inside a composite aircraft on the protection performance is analyzed. The role of the cable track in lightning protection is also verified. The calculation results show that the cable shield and track structure can provide good lightning protection for the cable in the electromagnetic exposure area, and the layout of the cable inside the aircraft has a greater impact on the protection performance. The analysis of cable shielding measures and their influencing factors can provide a reference for the performance improvement of cable screening measures for the lightning protection of composite aircraft.
12 September 2024 in IEEE Transactions on Electromagnetic Compatibility
Characteristic impedance is the key characteristic parameter to measure the impedance uniformity of coaxial cable. In the traditional impedance test method, the multiple reflection phenomenon caused by the internal impedance discontinuity point of the cable is one of the main causes of the cable impedance test error. Although a variety of methods have been used in the past and a lossless cable impedance reconstruction algorithm has been designed to quantify multiple reflection components, most of the calculation processes are complex and ignore the influence of cable attenuation on impedance testing, so that the test results still have large errors. Therefore, this article effectively compensates the signal transmission loss by establishing the cable attenuation characteristic model, and further optimizes the lossless cable impedance reconstruction algorithm. Combined with the attenuation characteristic model, the attenuation component is introduced in the multiple reflection calculation, and a new lossy cable impedance reconstruction algorithm is proposed. The frequency domain simulation verification is carried out in advanced design system software, and the vector network analyzer is used for experimental verification. The results show that the lossy reconstruction algorithm can obtain more accurate impedance test values, and the error is less than 2.5%.
In order to calculate the impedance of metal return network connected with composite skin, the volume based partial element equivalent circuit method is used to model the return network, and the impedance between the nodes of the return network at different frequencies is calculated. The influence of the contact resistance between the elements of the current return networks on the impedance is also considered. Moreover, the influence of some component parameters on impedance is analysed. The calculation results verify the applicability of the algorithm and the correctness of the calculation results and provide some references for the composite aircraft current return networks in the fault management and electrical protection system design.
9 November 2023 in IEEE Transactions on Aerospace and Electronic Systems
DC series arc is one of the most common faults of aircraft systems, which is very difficult to self-extinguish and being detected. Therefore, studying the dynamic characteristics of the arc and establishing an accurate simulation model are of great value for fault impact analysis and fault detection techniques design. Within this study, a heuristic average model is proposed based on the principle of arc power balance, and a current-controlled arc noise simulation method is provided based on the correlation mechanism between arc noise and arc current. By superimposing the arc noise on the proposed average model, the dynamic characteristics of the DC series arc can be accurately described. By comparing with existing models, the proposed model in this work has significantly improved simulation accuracy of the DC series arc.