Llorenç Cremonesi

Dr. Llorenç Cremonesi

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2018 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
Davide Raffaele CerattiDavide Raffaele Ceratti
Davide Raffaele Ceratti
YRYevgeny Rakita
Yevgeny Rakita
LCLlorenç Cremonesi
Llorenç Cremonesi
RTRon Tenne
Ron Tenne
VKVyacheslav Kalchenko
Vyacheslav Kalchenko
DCDavid Cahen
David Cahen

12 March 2021 in Materials Horizons
Verified
Journal Article
Open access
PDF file
Davide Raffaele CerattiDavide Raffaele Ceratti
Davide Raffaele Ceratti
ACA. V. Cohen
A. V. Cohen
RTR. Tenne
R. Tenne
YRY. Rakita
Y. Rakita
LSL. Snarski
L. Snarski
DCD. Cahen
D. Cahen
We find significant differences between degradation and healing at the surface or in the bulk for each of the different APbBr3 single crystals (A = CH3NH3 +, methylammonium (MA); HC(NH2)2 +, formamidinium (FA); and cesium, Cs+). Using 1- and 2-photon microscopy and photobleaching we conclude that kinetics dominate the surface and thermodynamics the bulk stability. Fluorescence-lifetime imaging microscopy, as well as results from several other methods, relate the (damaged) state of the halide perovskite (HaP) after photobleaching to its modified optical and electronic properties. The A cation type strongly influences both the kinetics and the thermodynamics of recovery and degradation: FA heals best the bulk material with faster self-healing; Cs+ protects the surface best, being the least volatile of the A cations and possibly through O-passivation; MA passivates defects via methylamine from photo-dissociation, which binds to Pb2+. DFT simulations provide insight into the passivating role of MA, and also indicate the importance of the Br3 − defect as well as predicts its stability. The occurrence and rate of self-healing are suggested to explain the low effective defect density in the HaPs and through this, their excellent performance. These results rationalize the use of mixed A-cation materials for optimizing both solar cell stability and overall performance of HaP-based devices, and provide a basis for designing new HaP variants.

3 May 2018 in Climate of the Past
Verified
Journal Article
Open access
PDF file
MSMarius Folden Simonsen
Marius Folden Simonsen
LCLlorenç Cremonesi
Llorenç Cremonesi
GBGiovanni Baccolo
Giovanni Baccolo
SBSamuel Bosch
Samuel Bosch
BDBarbara Delmonte
Barbara Delmonte
PVPaul Vallelonga
Paul Vallelonga
The Klotz Abakus laser sensor and the Coulter counter are both used for measuring the size distribution of insoluble mineral dust particles in ice cores. While the Coulter counter measures particle volume accurately, the equivalent Abakus instrument measurement deviates substantially from the Coulter counter. We show that the difference between the Abakus and the Coulter counter measurements is mainly caused by the irregular shape of dust particles in ice core samples. The irregular shape means that a new calibration routine based on standard spheres is necessary for obtaining fully comparable data. This new calibration routine gives an increased accuracy to Abakus measurements, which may improve future ice core record intercomparisons. We derived an analytical model for extracting the aspect ratio of dust particles from the difference between Abakus and Coulter counter data. For verification, we measured the aspect ratio of the same samples directly using a single-particle extinction and scattering instrument. The results demonstrate that the model is accurate enough to discern between samples of aspect ratio 0.3 and 0.4 using only the comparison of Abakus and Coulter counter data.

11 March 2022 in Advanced Functional Materials
Verified
Journal Article
Closed access
SASigalit Aharon
Sigalit Aharon
Davide Raffaele CerattiDavide Raffaele Ceratti
Davide Raffaele Ceratti
NJNaga Prathibha Jasti
Naga Prathibha Jasti
LCLlorenç Cremonesi
Llorenç Cremonesi
YFYishay Feldman
Yishay Feldman
DCDavid Cahen
David Cahen

26 April 2023 in Toxics
Verified
Journal Article
Open access
PDF file
Gloria MelziGloria Melzi
Gloria Melzi
ENEmma Nozza
Emma Nozza
MFMaria Agostina Frezzini
Maria Agostina Frezzini
SCSilvia Canepari
Silvia Canepari
RVRoberta Vecchi
Roberta Vecchi
Emanuela CorsiniEmanuela Corsini
Emanuela Corsini
The toxicity of particulate matter (PM) is strictly associated with its physical-chemical characteristics, such as size or chemical composition. While these properties depend on the origin of the particles, the study of the toxicological profile of PM from single sources has rarely been highlighted. Hence, the focus of this research was to investigate the biological effects of PM from five relevant sources of atmospheric PM: diesel exhaust particles, coke dust, pellet ashes, incinerator ashes, and brake dust. Cytotoxicity, genotoxicity, oxidative, and inflammatory response were assessed in a bronchial cell line (BEAS-2B). BEAS-2B cells were exposed to different concentrations (25, 50, 100, and 150 μg/mL medium) of particles suspended in water. The exposure lasted 24 h for all the assays performed, except for reactive oxygen species, which were evaluated after 30 min, 1 h, and 4 h of treatment. The results showed a different action of the five types of PM. All the tested samples showed a genotoxic action on BEAS-2B, even in the absence of oxidative stress induction. Pellet ashes seemed to be the only ones able to induce oxidative stress by boosting the formation of reactive oxygen species, while brake dust resulted in the most cytotoxic. In conclusion, the study elucidated the differential response of bronchial cells to PM samples generated by different sources. The comparison could be a starting point for a regulatory intervention since it highlighted the toxic potential of each type of PM tested.

13 January 2020 in Aerosol Science and Technology
Verified
Journal Article
Closed access
LCLlorenç Cremonesi
Llorenç Cremonesi
APAndrea Passerini
Andrea Passerini
ATAgostino Tettamanti
Agostino Tettamanti
BPBruno Paroli
Bruno Paroli
BDBarbara Delmonte
Barbara Delmonte
MPMarco Potenza
Marco Potenza
We describe a robust, portable, deployable instrument for multiparametric optical characterization of single airborne particles. It is based on the Single Particle Extinction and Scattering method with additional sensors at 45° and 90° angles. Four independent optical parameters are associated to each particle. Basically, it provides a rigorous measurement of the extinction cross section and the complex amplitude of the forward scattered field. Moreover, thanks to the multiparametric single particle approach, it is possible to roughly classify the particles within a size range from a few hundreds of nanometers to some micrometers. By assigning a reasonable single scattering albedo for each population, our data are enough to fit the phase function with acceptable uncertainties. We report here the results of tests performed with water droplets, generating well controlled data without any free parameters. Data analysis is described in detail. We also report measurements performed on urban aerosol collected in the city of Milan by recovering the optical properties and feeding radiative transfer models. The findings reported here support the importance of an accurate measurement of the phase function, as already established by the Community. Copyright © 2019 American Association for Aerosol Research