Fanglin Zuo

Mr. Fanglin Zuo


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2023 in IEEE Access
Verified
Journal Article
Open access
Min WangMin Wang
Min Wang
FZFanglin Zuo
Fanglin Zuo
CWChao Wu
Chao Wu
ZYZixuan Yu
Zixuan Yu
YCYuan Chen
Yuan Chen
HWHuilin Wang
Huilin Wang
The load in the power grid is often affected by many factors, and the coupling relationship among them changes dynamically with time. For smart grids with massive amounts of data, a short-term load forecasting technique based on time pattern attention and a long short-term memory network considering time-dependent intrinsic cross correlation (TDICC) is proposed. Based on source-load dynamic correlation analysis, TDICC is proposed to track and correct the multi-timescale dynamic correlation of two signal overruns or lags, which realizes the transformation of correlation description from two-dimensional space to three-dimensional space and expands its ability to describe multi-timescale dynamic correlation. Finally, the actual load data are used for example analysis, and the results show that the proposed method can tap the dynamic correlation between multiple influencing factors and load, and has higher prediction accuracy compared with other models, which provides a more accurate data base for power system dispatching.

20 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
Min WangMin Wang
Min Wang
HWHuilin Wang
Huilin Wang
FZFanglin Zuo
Fanglin Zuo
JZJie Zou
Jie Zou
YCYuan Chen
Yuan Chen
ZYZixuan Yu
Zixuan Yu
With a large amount of distributed power and energy storage access, the traditional three-phase unbalanced treatment of a power distribution system is mainly aimed at the three-phase unbalance of a load, which cannot effectively address the three-phase unbalance problem of a power distribution network after a large number of single-phase photovoltaic access. Therefore, this paper proposes a three-phase unbalanced treatment strategy for the distribution network, which considers the joint regulation ability of single-phase photovoltaic and energy storage and the regulation ability of a reactive power compensation device. Firstly, the joint regulation ability of single-phase photovoltaic and energy storage under different photovoltaic permeability is analyzed. Secondly, according to the joint regulation ability of single-phase photovoltaic and energy storage and the regulation ability of reactive power compensation device, the three-phase power optimization model is constructed to minimize the three-phase unbalance degree and regulation cost, and the JAYA optimization algorithm is used to solve the model. Finally, the 33-node distribution system is used to verify the effectiveness of the proposed strategy.



20 October 2023
Verified
Conference Paper
Closed access
Min WangMin Wang
Min Wang
JZJie Zou
Jie Zou
JZJun Zhou
Jun Zhou
ZZZijian Zhang
Zijian Zhang
Huilin WangHuilin Wang
Huilin Wang
FZFanglin Zuo
Fanglin Zuo
With the development of the new power system, the large number of new energy units in the system leads to inertia decline, and the problem of frequency stability caused by various faults is particularly serious. In order to solve the problem of over-cutting faced by the traditional generator tripping method, an emergency frequency control strategy combining regulation and cutting out new energy units is proposed in this paper. Firstly, based on the improved AHP-MARCOS method to quantify the comprehensive control performance of control means from various factors, the priority problem of system-level emergency control units is solved. Secondly, the system response model is established according to the response characteristics of different new energy units. Finally, the optimized emergency frequency control strategy is proposed according to the built model, and the calculation example is analyzed in combination with a provincial power grid. The effectiveness of the emergency frequency control strategy is verified.