Shruthi Eshwar

Dr. Shruthi Eshwar

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2023 in Gels
Verified
Journal Article
Open access
PDF file
SEShruthi Eshwar
Shruthi Eshwar
KRKranti Reddy
Kranti Reddy
SMSupriya Manvi
Supriya Manvi
ABAarya N. Bharadwaj
Aarya N. Bharadwaj
SSSudarshan Sajjan
Sudarshan Sajjan
VJVipin Jain
Vipin Jain
Periodontal diseases significantly impact about half of the global population, and their treatment often encompasses relieving symptoms as well as regenerating the destroyed tissues. Revolutionary research in the management of periodontal disease includes biomaterials, a boon to re-generative dentistry owing to their excellent biological properties: non-toxicity, anti-inflammatory, biocompatibility, biodegradability, and adhesion. This study aimed to fabricate an injectable fucoidan containing chitosan hydrogel and prove its effectiveness in periodontal bone regeneration. The injectable hydrogel was prepared using the sol-gel method and was subjected to various physical, chemical, and biological characterizations to understand its efficacy in formation of new bone. The effectiveness of the developed hydrogel was assessed in periodontal bony defects to study the soft and hard tissue changes. A total of 40 periodontitis patients with bony defects were recruited and randomized into two groups to receive fucoidan-chitosan hydrogel and concentrated growth factor, respectively. Customized acrylic stents were used to guide the hydrogel placement into the defect site. Post-surgical changes in clinical parameters were assessed at 3, 6, and 9 months to appreciate the soft and hard tissue changes using repeated measures analysis of variance and Bonferroni’s post hoc test. Significance was kept at 5%. The porosity, water uptake of the prepared hydrogel showed good efficacy, with particle size of the fucoidan containing chitosan hydrogel of 6.000 nm. The MG-63 osteoblasts cell line revealed biocompatibility, biodegradability and showed slow and sustained drug release, increased cell proliferation, and enhanced alkaline phosphatase secretion. Mineralization assay was greatest in the fucoidan containing chitosan hydrogel. Clinically, it exhibited significantly lower probing depth values and a higher mean improvement in clinical attachment level as compared to the concentrated growth factor (CGF) group at the end of 3 and 6 months (p < 0.05). The mean of the defect fills in the fucoidan containing chitosan group was 1.20 at the end of 9 months (p < 0.001) as compared with defect fills observed in the CGF group. The presence of fucoidan in the hydrogel significantly contributed to bone regeneration in humans, thus strengthening its potential in tissue engineering. Fucoidan-chitosan will be a promising biomaterial for bone tissue regeneration.

14 July 2023 in Gels
Verified
Journal Article
Open access
PDF file
PGPoornima Gopalakrishna
Poornima Gopalakrishna
RJRajamma Abburu Jayaramu
Rajamma Abburu Jayaramu
SSSateesha SB
Sateesha SB
SEShruthi Eshwar
Shruthi Eshwar
NSNikhil V. Suresh
Nikhil V. Suresh
EKEl-Sayed Khafagy
El-Sayed Khafagy
Periodontitis is an inflammatory disorder associated with dysbiosis and characterized by microbiologically related, host-mediated inflammation that leads to the damage of periodontal tissues including gingiva, connective tissues, and alveolar bone. The aim of this study was to develop an in situ gel consisting of piperine. Eight in situ gel formulations were designed by varying the concentration of deacylated gellan gum cross-linked with sodium tripolyphosphate, and poloxamer-407. The prepared gels were evaluated for gelation temperature, gelation time, viscosity, piperine-loading efficiency, and piperine release. Finally, the optimized formula was evaluated for anti-inflammatory effectiveness among human patients during a 14-day follow-up. The optimized in situ gel formulation exhibited a gelation temperature of 35 ± 1 °C, gelling of 36 ± 1 s, excellent syringeability, and piperine loading of 95.3 ± 2.3%. This formulation efficiently sustained in vitro drug release for up to 72 h. In vivo studies revealed an efficient sol-to-gel transformation of optimized in situ gel formulation at physiological conditions, permitting an efficient residence time of the formulation within a periodontitis pocket. Most importantly, a clinical study revealed that treatment with the optimized formulation elicited a significant reduction in the mean plaque score (p = 0.001), gingival index (p = 0.003), and pocket depth (p = 0.002), and exerted a potent anti-inflammatory potential, compared to the control group. Collectively, piperine-loaded in situ gel might represent a viable therapeutic approach for the management of gingival and periodontal diseases.

19 April 2018 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
JMJoji Markose
Joji Markose
SEShruthi Eshwar
Shruthi Eshwar
SSSuresh Srinivas
Suresh Srinivas
VJVipin Jain
Vipin Jain

1 January 2021 in Revista Paulista de Pediatria
Verified
Journal Article
Open access
PDF file
RDRuttika Vijay Desai
Ruttika Vijay Desai
NBNivedita Chandrashekhar Badrapur
Nivedita Chandrashekhar Badrapur
HMHarshitha Mittapalli
Harshitha Mittapalli
BSBagepalli Keshavappa Srivastava
Bagepalli Keshavappa Srivastava
SEShruthi Eshwar
Shruthi Eshwar
VJVipin Jain
Vipin Jain
Objective: To investigate the impact of “Brush Up” - a mobile application, on oral hygiene behaviours of 4-6-year-old children in Bangalore city. Methods: In this experimental study, 247 children aged 4-6, were randomly divided into three groups. Considering “Brush Up” is a mobile application, parents of the children in Group 1 (n=82) downloaded the application on their smartphones. Children in Group 2 (n=83) and Group 3 (n=82) received tooth brushing instructions by an educative video and manual demonstration, respectively. Effectiveness of tooth brushing was assessed with plaque scores, which were recorded for all the groups at baseline and one month using Visible Biofilm Index. Results: Wilcoxon signed rank test showed a significant improvement in the tooth brushing behaviour for the Brush Up group, which was indicated by a lower plaque score after a follow-up of one month. Kruskal-Wallis test followed by post-hoc test showed that the mean ranks of plaque scores of Brush Up group are consistently lower than those of video demonstration group and manual demonstration group. Conclusions: The lower plaque score in subsequent follow-up in Brush Up group suggests that using a smart system can enhance learning a correct tooth brushing method in young children and can also help in implementing the required reinforcement and motivation to brush and aid in better plaque control.

1 June 2017 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
SSS Suresh
S Suresh
JMJoji Markose
Joji Markose
SEShruthi Eshwar
Shruthi Eshwar
KRK Rekha
K Rekha
VJVipin Jain
Vipin Jain
Introduction Comparison of platform switched (PS), sloping shoulder, and regular implants on stress reduction in various bone densities with finite element analysis. Materials and methods A total of 12 three-dimensional finite element models were built to analyze the stress distribution model. Nobel Biocare 4.3 × 8 mm regular platform replace select implant with matching diameter easy abutment, Nobel Biocare 4.3 × 8 mm replace select implant PS with 3.5 mm diameter easy abutment, Bicon 4 × 8 mm implant with 4 mm diameter sloping shoulder abutments were created virtually in compact bone density using software. The 130 N axial force and a 90 N oblique loading force were applied to the abutment to analyze the stress. Results Under horizontal and vertical loading, the sloping shoulder implant had lesser stresses in cancellous bone when compared with PS and regular implants. Sloping shoulder implant showed more stress distribution at implant–abutment interface and at crestal area, whereas with regular implants, the stresses were distributed at cortical area. Conclusion Sloping shoulder implant in subcrestal position is much favorable for bone growth, stress distribution, and preservation of remaining bone. Clinical significance Use of sloping shoulder implant design distributes the stress apically and creates lesser stresses when compared with PS implants. How to cite this article Markose J, Suresh S, Eshwar S, Rekha K, Jain V, Manvi S. Comparison of Platform Switched and Sloping Shoulder Implants on Stress Reduction in various Bone Densities: Finite Element Analysis. J Contemp Dent Pract 2017;18(6):510-515.

11 May 2016 in The Open Dentistry Journal
Verified
Journal Article
Open access
SEShruthi Eshwar
Shruthi Eshwar
RKRekha K
Rekha K
VJVipin Jain
Vipin Jain
SMSupriya Manvi
Supriya Manvi
SKShivani Kohli
Shivani Kohli
SBShekhar Bhatia
Shekhar Bhatia
Introduction: : Mouthrinses have been in use for centuries as breath fresheners, medicaments, and antiseptics. Dill is said to be a good source of calcium, manganese and iron. It contains flavonoids known for their antioxidant, anti-inflammatory, and antiviral properties. Dill can help with microbial infections in the mouth; and its anti-oxidants minimize damage caused by free radicals to the gums and teeth. Being a good source of calcium, dill also helps with bone and dental health. Aims and Objectives: : To compare the effectiveness of commercially available 0.2% chlorhexidine gluconate mouthrinse and dill seed oil mouthrinse on plaque levels and gingivitis. Material and Methods: : A randomized controlled, double blind parallel arm study was conducted over 90 days on 90 subjects. The subjects were randomly divided into 2 groups and baseline data was collected using Loe and Silness gingival index and Quigley Hein plaque index and oral prophylaxis was performed on all the subjects. The mouthrinses included in the present study were dill seed oil and Hexodent (0.2% chlorhexidine gluconate). Intervention regarding the mouthrinsing was given to the subjects and were followed up for 45 days and 90 days, after this post intervention changes were assessed using the respective indices. Results: : It was observed that there is no significant difference in gingival & plaque scores among two mouthrinses from baseline to 45 days and 90 days. It was observed that there is statistical difference in gingival and plaque scores when compared with baseline to 45 days (p<0.001), baseline to 90 days (p<0.001) and 45 days to 90 days (p<0.001) when intergroup comparisons were done. Conclusion: : It was concluded that dill seed oil and Hexodent (0.2% chlorhexidine gluconate) mouthrinse have similar antiplaque and antigingival effectiveness.