Udit Saxena

Dr. Udit Saxena

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2016 in International Journal of Research in Medical Sciences
Verified
Journal Article
Open access
PDF file
SSSuhani Sharma
Suhani Sharma
RTRajesh Tripathy
Rajesh Tripathy
USUdit Saxena
Udit Saxena
Speech in noise tests that measure the perception of speech in presence of noise are now an important part of audiologic tests battery and hearing research as well. There are various tests available to estimate the perception of speech in presence of noise, for example, connected sentence test, hearing in noise test, words in noise, quick speech-in-noise test, bamford-kowal-bench speech-in-noise test, and listening in spatialized noise-sentences. All these tests are different in terms of target age, measure, procedure, speech material, noise, normative, etc. Because of the variety of tests available to estimate speech-in-noise abilities, audiologists often select tests based on their availability, ease to administer the test, time required in running the test, age of the patient, hearing status, type of hearing disorder and type of amplification device if using. A critical appraisal of these speech-in-noise tests is required for the evidence based selection and to be used in audiology clinics. In this article speech-in-noise tests were critically appraised for their conceptual model, measurement model, normatives, reliability, validity, responsiveness, item/instrument bias, respondent burden and administrative burden. Selection of a standard speech-in-noise test based on this critical appraisal will also allow an easy comparison of speech-in-noise ability of any hearing impaired individual or group across audiology clinics and research centers. This article also describes the survey which was done to grade the speech in noise tests on the various appraisal characteristics.

1 January 2018 in Indian Journal of Otology
Verified
Journal Article
Closed access
PDF file
HVHimanshu Verma
Himanshu Verma
BSBhanu Shukla
Bhanu Shukla
BRB Srinivasa Rao
B Srinivasa Rao
USUdit Saxena
Udit Saxena
Aim: The present study aimed to investigate speech in noise perception abilities in normal-hearing adults using different types of noise (i.e., speech babble, traffic noise, and speech spectrum noise) and at different signal-to-noise ratios (SNRs) (i.e., +5 dB, 0 dB, −5 dB, and −10 dB). Methods: A total of 109 individuals with mean age of 23 years were participated in the study. All participants had English as second language and Telugu as native and first language. English disyllabic words (Hrish et al.) were used as speech stimuli under different noises and different SNRs. Results: Results have shown that for any type of noise the speech perception scores changed with the variance in SNRs, the scores have decreased when the SNRs were decreased from 0 dB to −10 dB SNR, and the scores have increased when SNRs increased from 0 dB to +5 dB SNR. Conclusion: From this study, it can be concluded that speech perception score in noise depends on the type of noise used in testing the speech in noise abilities. This factor is very important in the selection of the noise type when measuring speech perception in the presence of noise. It was also seen that change in noise level also had a different impact on speech perception in noise abilities.

30 March 2015 in International Journal of Audiology
Verified
Journal Article
Closed access
USUdit Saxena
Udit Saxena
CAChris Allan
Chris Allan
PAPrudence Allen
Prudence Allen
Previous data suggested that children with suspected auditory processing disorders (APD) often show elevated or absent acoustic reflex thresholds, especially in crossed conditions (e.g. Allen & Allan, 2014 ). This study further explored these effects by measuring acoustic reflex growth functions (ARGF). Crossed and uncrossed ARGF slopes were obtained by linear fits between reflex amplitudes and increases in activator level from threshold to 15 dB above it. Normal-hearing adults, typically developing children and children with reported listening difficulties and suspected of having an APD, participated. The ARGF slopes were shallower in crossed than in uncrossed conditions for all groups but the magnitude of the effect was significantly greater in the children with suspected APD. There were no differences between the typically developing children and the adults. The results suggest shallower ARGFs in children with suspected APD. Given the role of the acoustic reflex in facilitating hearing speech in noise these findings may begin to shed light on physiologic explanations for some of the difficulties that are reported by children with suspected APD.

30 April 2021
Verified
Journal Article
Open access
PDF file
USUdit Saxena
Udit Saxena
GCGish Chacko
Gish Chacko
SKS B Rathna Kumar
S B Rathna Kumar
VNVikas Nagabathula
Vikas Nagabathula
VDVenkata Damarla
Venkata Damarla
Purpose: For ten months the world has witnessed a global pandemic “COVID-19”, which disturbed many lives either directly and/or indirectly. COVID-19 has proven challenging to the public health system and considering the hearing healthcare, an internet-based survey was conducted on how COVID-19 affected the services to Cochlear Implant users and which consecutively affected their communication needs. Methods: The study was carried out during the period of June–August 2020. The questionnaire consisted of 38 questions, developed and presented via “Google forms”. The questions were based on the common problems faced by the Cochlear Implant users. The nature of the questions was generally focused on how COVID-19 affected their child’s communication due to limited services. The questionnaire was self-administered and the time taken would be 10–15 minutes. The parents of the Cochlear Implanted children were asked to answer the survey with the best of their experience. Results: The overall survey results showed that majority of the respondents observed a variety of problems related to the usage, management and maintenance of Cochlear Implant during this COVID-19 pandemic condition. Conclusions: This report suggests that hearing health care requires a radical rethinking of service delivery and create the momentum to rapidly formulate innovative digital and tele-health approaches in response to these changing situations.

27 June 2019 in International Journal of Otorhinolaryngology and Head and Neck Surgery
Verified
Journal Article
Open access
PDF file
BSBhanu Pratap Singh
Bhanu Pratap Singh
RMRajendra Basayya Metgudmath
Rajendra Basayya Metgudmath
DSDivya Singh
Divya Singh
USUdit Saxena
Udit Saxena
Background: The approach to sphenoid sinus still remains a clinical challenge, despite the arrival of endoscopy, computed tomography (CT) and functional endoscopic sinus surgery (FESS). The complex and variable anatomy of the sphenoid sinus can be difficult to appreciate with standard axial or coronal CT images of the sinus. The study was done with the objective to study the anatomy of the sphenoid sinus and its variations, and to compare the prevalence of variants obtained in our study with the reported cases in the literature.Methods: The CT scans of 168 normal slides obtained from 84 patients with paranasal sinus were analysed using triplanar imaging provided by 64-slice spiral CT. The prevalence of each of the sphenoid sinus variation was also analysed. Results: Results showed that the prevalence of pneumatization of the anterior clinoid process, greater wing of the sphenoid, and the pterygoid process was 17.85%, 22.61% and 32.14%, respectively. Protrusion of the internal carotid artery, optic nerve, maxillary nerve, and the vidian nerve was 47.61%, 36.90%, 25% and 26.19%, respectively. Dehiscence of internal carotid artery, optic nerve, maxillary nerve, and the vidian nerve was 30.95%, 29.76%, 14.28% and 22.61%, respectively. The prevalence of pneumatization in the Onodi cells was seen in 17.85% of the cases. Association of septa with an internal carotid artery was seen in 29.7% of the cases. Septa attachment to the optic nerve was also observed in 27.3% of the cases.Conclusions: The triplanar imaging (section thickness of 1 mm) is a better three-dimensional image of the sphenoid sinus, compared to coronal imaging. Triplanar imaging guides the surgical approach of the sphenoid sinus with mentally reconstructed three-dimensional images.

1 June 2017 in Journal of the American Academy of Audiology
Verified
Journal Article
Closed access
PDF file
USUdit Saxena
Udit Saxena
CAChris Allan
Chris Allan
PAPrudence Allen
Prudence Allen
Background:Previous studies have suggested elevated reflex thresholds in children with auditory processing disorders (APDs). However, some aspects of the child’s ear such as ear canal volume and static compliance of the middle ear could possibly affect the measurements of reflex thresholds and thus impact its interpretation. Sound levels used to elicit reflexes in a child’s ear may be higher than predicted by calibration in a standard 2-cc coupler, and lower static compliance could make visualization of very small changes in impedance at threshold difficult. For this purpose, it is important to evaluate threshold data with consideration of differences between children and adults.Purpose:A set of studies were conducted. The first compared reflex thresholds obtained using standard clinical procedures in children with suspected APD to that of typically developing children and adults to test the replicability of previous studies. The second study examined the impact of ear canal volume on estimates of reflex thresholds by applying real-ear corrections. Lastly, the relationship between static compliance and reflex threshold estimates was explored.Research Design:The research is a set of case‐control studies with a repeated measures design.Study Sample:The first study included data from 20 normal-hearing adults, 28 typically developing children, and 66 children suspected of having an APD. The second study included 28 normal-hearing adults and 30 typically developing children.Data Collection and Analysis:In the first study, crossed and uncrossed reflex thresholds were measured in 5-dB step size. Reflex thresholds were analyzed using repeated measures analysis of variance (RM-ANOVA). In the second study, uncrossed reflex thresholds, real-ear correction, ear canal volume, and static compliance were measured. Reflex thresholds were measured using a 1-dB step size. The effect of real-ear correction and static compliance on reflex threshold was examined using RM-ANOVA and Pearson correlation coefficient, respectively.Results:Study 1 replicated previous studies showing elevated reflex thresholds in many children with suspected APD when compared to data from adults using standard clinical procedures, especially in the crossed condition. The thresholds measured in children with suspected APD tended to be higher than those measured in the typically developing children. There were no significant differences between the typically developing children and adults. However, when real-ear calibrated stimulus levels were used, it was found that children’s thresholds were elicited at higher levels than in the adults. A significant relationship between reflex thresholds and static compliance was found in the adult data, showing a trend for higher thresholds in ears with lower static compliance, but no such relationship was found in the data from the children.Conclusions:This study suggests that reflex measures in children should be adjusted for real-ear-to-coupler differences before interpretation. The data in children with suspected APD support previous studies suggesting abnormalities in reflex thresholds. The lack of correlation between threshold and static compliance estimates in children as was observed in the adults may suggest a nonmechanical explanation for age and clinically related effects.