The association of short-term blood pressure (BP) variability (BPV) with cardiovascular events (CVEs) is controversial. Aim of this study was to investigate whether BPV measured as weighted 24-h SD was associated with CVE in a prospective cohort study of young patients screened for stage 1 hypertension. We performed 24-h ambulatory BP monitoring in 1206 participants aged 33.1 ± 8.5 years, untreated at baseline examination. Participants were divided into two categories with low (<12.8 mmHg) or high (≥12.8 mmHg) SBPV. Hazard ratios for CVE associated with BPV expressed either as continuous or categorical variable were computed from multivariable Cox models. During 15.4 ± 7.4 years of follow-up there were 69 fatal and nonfatal CVE. In multivariable Cox models, high SBPV was an independent predictors of CVE [2.75 (1.65–4.58); P = 0.0001] and of coronary events [3.84 (2.01–7.35), P < 0.0001]. Inclusion in the model of development of hypertension requiring treatment during the follow-up, did not reduce the strength of the associations. Addition of SBPV to fully adjusted models had significant impact on risk reclassification and integrated discrimination (relative integrated discrimination improvement for BPV as continuous variable: 13.5%, P = 0.045, and for BPV as categorical variable: 26.6%, P = 0.001). When the coefficient of variation was used as BPV metric similar results were obtained. Of note, in all Cox models average 24-h BP was no longer an independent predictor of outcome after BPV was included. Short-term BPV adds to the risk stratification for cardiovascular events in young-to-middle-age patients screened for stage 1 hypertension over and above traditional 24-h ambulatory monitoring indexes.
17 January 2015 in European Journal of Epidemiology
Objectives: Although the upper arm has the shape of a truncated cone, cylindrical cuffs and bladders are currently used for blood pressure (BP) measurement. The aim of this study was to ascertain whether cylindrical and tronco-conical cuffs provide different readings according to arm size and shape. Design: We studied 220 individuals with arm circumference ranging from 22 to 42.5 cm. Four different cylindrical and four different tronco-conical bladders of appropriate size were used. Sequential same-arm measurements were performed in triplicate by two observers using the two cuffs in a random order. In 100 individuals, the actual pressure transmitted to the arm surface by the two cuffs at the central point was also measured. Results: Upper arm shape was tronco-conical in all of the individuals. In a multiple regression, conicity was related to arm circumference (P < 0.001) and length (P = 0.001). Arm conicity and size were independently related to the between-cuff SBP (P = 0.001 and 0.002, respectively) and DBP (P = 0.001 and <0.001, respectively) discrepancies. In the group with arm circumference of 37.5–42.5 cm, the cylindrical cuff overestimated BP measured with the tronco-conical cuff by 2.0 ± 0.4/1.8 ± 0.3 mmHg (P = 0.001 and <0.001). In this group, 15% of individuals found hypertensive with the cylindrical cuff were normotensive when assessed with the conical cuff. Differences as great as 9.7/7.8 mmHg were found in individuals with large arms and slant angle equal to or less than 83°. Conclusion: In obese people, the upper arm may have a pronounced tronco-conical shape and cylindrical cuffs may overestimate BP. Tronco-conical cuffs should be used for BP measurement in individuals with large arms.
The aim of this study was to investigate the effect of cigarette smoking on peripheral and central blood pressure (BP) in a group of young stage I hypertensives. A total of 344 untreated subjects from the HARVEST study were examined (mean age 37±10 years). Patients were divided into three groups based on smoking status: non-smokers, light smokers (⩽5 cigarettes/day) and moderate-to-heavy smokers (>5 cigarettes/day); and into three groups by age: 18–29, 30–39 and ⩾40 years. Central BP measurements and augmentation index (AIx) were calculated from brachial pressure waveform, with applanation tonometry, by means of the Specaway DAT System plus a Millar tonometer. The central waveform was derived from peripheral BP using the same software system of the SphygmoCor System pulse wave analysis. In addition, two indirect measurements of arterial stiffness were calculated: pulse pressure (PP) and systolic BP amplification. Central systolic BP and PP were higher in smokers than in non-smokers (systolic BP: 121.9±13.1 mmHg in non-smokers, 127.2±16.5 mmHg in light smokers, 126.7±15.3 mmHg in those who smoked >5 cigarettes/day, p=0.009; PP: 37.7±9.8 mmHg, 41.5±13.1 mmHg, 41.9±10.5 mmHg, respectively, p=0.005). Lower systolic BP amplification (p<0.001) and PP amplification (p=0.001) were observed in smokers compared to non-smokers. In a two-way ANCOVA analysis, systolic BP amplification markedly declined across the three age groups (p=0.0002) and from non-smokers to smokers (p=0.0001), with a significant interaction between smoking and age group (p=0.05). The AIx was higher in smokers compared to non-smokers (p=0.024). In young hypertensives, smoking has a detrimental effect on central BP, accelerating the age-related decline in BP amplification.
The role of pulse pressure in young individuals remains controversial. The aim of the present study was to investigate the clinical significance of elevated pulse pressure in young- to middle-aged subjects screened for stage 1 hypertension. We examined 1241 subjects (mean age, 33.1±8.4 years) from the HARVEST (Hypertension Ambulatory Recording Venetia Study), during a median follow-up of 12.1 years. To evaluate the predictive value of pulse pressure and mean blood pressure for future hypertension needing treatment and for cardiovascular events, participants were grouped into pressure tertiles. Significant determinants of pulse pressure were male sex ( P =0.029), younger age ( P <0.001), physical activity ( P =0.003), heart rate ( P <0.001), systolic white-coat effect ( P <0.001), and stroke volume (n=829; P <0.001). During follow-up, 65.1% of participants developed hypertension requiring pharmacological treatment and 5.1% experienced a cardiovascular event. Participants in the highest pulse pressure tertile had a reduced risk of incident hypertension compared with those of the bottom tertile (hazard ratio, 0.75; 95% confidence interval, 0.62–0.91; P =0.003). In contrast, participants in the top mean blood pressure tertile had an increase in risk (1.91; 1.57–2.33; P <0.001). In addition, participants in the highest pulse pressure tertile had a reduced risk of cardiovascular events (0.35; 0.17–0.73; P =0.005) and those in the top mean blood pressure tertile had an increase in risk (3.06; 1.32–7.09; P =0.009). Our data show that in subjects <45 years, only mean blood pressure is a predictor of adverse outcome whereas high pulse pressure even carries a reduced risk.
Objective: Rectangular (cylindrical) cuffs and bladders are currently used for blood pressure (BP) measurement at the upper arm. However, large arms have a troncoconical shape, which make cylindrical cuffs potentially unsuitable. Aim of this study was to investigate the effect of the shape of the cuff on BP measurement in very obese participants. Methods: In 33 participants with upper arm mid-circumference at least 42 cm and 33 participants of control, cylindrical and troncoconical cuffs of appropriate size were compared. In addition, in the obese participants, the pressure transmitted to the arm under the cuffs was measured at five cuff pressure levels using a paper-thin pressure sensor. Results: In all obese participants, the upper arm shape was troncoconical (mean ± SD slant angle, 84.1 ± 1.4°). In this group, SBP and DBP differences between the troncoconical and the cylindrical cuff were −5.3 ± 4.0 and −3.0 ± 4.3 mmHg, respectively (P < 0.001/=0.01 versus controls). In the obese participants of the top BP quintile, the between-cuff SBP difference was −9.1 ± 5.1 mmHg. Arm slant angle was an independent predictor of the between-cuff SBP discrepancy (P = 0.003). When the cylindrical cuff was used, measurement with the pressure sensor showed a marked disagreement between the pressure in the cuff and the pressure transmitted to the arm (mean difference, −10.2 ± 5.2 mmHg) a difference, which increased with increasing level of the pressure pumped in the cuff. Conclusion: In very obese people, cylindrical cuffs overestimate BP chiefly in people with high SBP and thus only troncoconical cuffs should be used.