Ke Sheng

Ke Sheng


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
ATAngelia Tran
Angelia Tran
JZJingjing Zhang
Jingjing Zhang
KWKaley Elizabeth Woods
Kaley Elizabeth Woods
VYVictoria Yu
Victoria Yu
DNDan Nguyen
Dan Nguyen
KSKe Sheng
Ke Sheng
Intensity-modulated proton therapy (IMPT), non-coplanar 4π intensity-modulated radiation therapy (IMRT), and volumetric-modulated arc therapy (VMAT) represent the most advanced treatment methods based on heavy ion and X-rays, respectively. Here we compare their performance for prostate cancer treatment. Ten prostate patients were planned using IMPT with robustness optimization, VMAT, and 4π to an initial dose of 54 Gy to a clinical target volume (CTV) that encompassed the prostate and seminal vesicles, then a boost prescription dose of 25.2 Gy to the prostate for a total dose of 79.2 Gy. The IMPT plans utilized two coplanar, oblique scanning beams 10° posterior of the lateral beam positions. Range uncertainties were taken into consideration in the IMPT plans. VMAT plans used two full, coplanar arcs to ensure sufficient PTV coverage. 4π plans were created by inversely selecting and optimizing 30 beams from 1162 candidate non-coplanar beams using a greedy column generation algorithm. CTV doses, bladder and rectum dose volumes (V40, V45, V60, V65, V70, V75, and V80), R100, R50, R10, and CTV homogeneity index (D95/D5) were evaluated. Compared to IMPT, 4π resulted in lower anterior rectal wall mean dose as well as lower rectum V40, V45, V60, V65, V70, and V75. Due to the opposing beam arrangement, IMPT resulted in significantly (p < 0.05) greater femoral head doses. However, IMPT plans had significantly lower bladder, rectum, and anterior rectal wall max dose. IMPT doses were also significantly more homogeneous than 4π and VMAT doses. Compared to the VMAT and 4π plans, IMPT treatment plans are superior in CTV homogeneity and maximum point organ-at-risk (OAR) doses with the exception of femur heads. IMPT is inferior in rectum and bladder volumes receiving intermediate to high doses, particularly to the 4π plans, but significantly reduced low dose spillage and integral dose, which are correlated to secondary cancer for patients with expected long survival. The dosimetric benefits of 4π plans over VMAT are consistent with the previous publication.

1 February 2015 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JRJean-Claude M. Rwigema
Jean-Claude M. Rwigema
DNDan Nguyen
Dan Nguyen
DHDwight E. Heron
Dwight E. Heron
ACAllen M. Chen
Allen M. Chen
PLPercy Lee
Percy Lee
KSKe Sheng
Ke Sheng

19 April 2019 in Medical Physics
Verified
Journal Article
Closed access
PDF file
NTNuo Tong
Nuo Tong
SGShuiping Gou
Shuiping Gou
SYShuyuan Yang
Shuyuan Yang
MCMinsong Cao
Minsong Cao
KSKe Sheng
Ke Sheng

15 December 2011 in Advances in Urology
Verified
Journal Article
Open access
PDF file
RNRajakumar Nagarajan
Rajakumar Nagarajan
DMDaniel Margolis
Daniel Margolis
SRSteven Raman
Steven Raman
KSKe Sheng
Ke Sheng
CKChristopher King
Christopher King
michael albert thomasmichael albert thomas
michael albert thomas
The purpose of our study was to compare the apparent diffusion coefficient (ADC) derived from diffusion-weighted imaging (DWI) of prostate cancer (PCa) patients with three classes of pathological Gleason scores (GS). Patients whose GS met these criteria (GS 3 + 3 , GS 3 + 4 , and GS 4 + 3 ) were included in this study. The DWI was performed using ???? values of 0, 50, and 400s/mm2 in 44 patients using an endorectal coil on a 1.5T MRI scanner. The apparent diffusion coefficient (ADC) values were calculated from the DWI data of patients with three different Gleason scores. In patients with a high-grade Gleason score ( 4 + 3 ), the ADC values were lower in the peripheral gland tissue, pathologically determined as tumor compared to low grade ( 3 + 3 and 3 + 4 ). The mean and standard deviation of the ADC values for patients with GS 3 + 3 , GS 3 + 4 , and GS 4 + 3 were 1 . 1 3 5 ± 0 . 1 1 9 , 0 . 9 7 6 ± 0 . 1 0 3 and 0 . 8 3 1 ± 0 . 0 8 7 mm2/sec. The ADC values were statistically significant ( ???? < 0 . 0 5 ) between the three different scores with a trend of decreasing ADC values with increasing Gleason scores by one-way ANOVA method. This study shows that the DWI-derived ADC values may help differentiate aggressive from low-grade PCa.

14 October 2015 in Medical Physics
Verified
Journal Article
Closed access
VYVictoria Y. Yu
Victoria Y. Yu
ATAngelia Tran
Angelia Tran
DNDan Nguyen
Dan Nguyen
Minsong CaoMinsong Cao
Minsong Cao
DRDan Ruan
Dan Ruan
KSKe Sheng
Ke Sheng

1 January 2016 in Advances in Radiation Oncology
Verified
Journal Article
Open access
KWKaley Woods
Kaley Woods
DNDan Nguyen
Dan Nguyen
ATAngelia Tran
Angelia Tran
VYVictoria Y. Yu
Victoria Y. Yu
MCMinsong Cao
Minsong Cao
KSKe Sheng
Ke Sheng
The 4π static noncoplanar radiation therapy delivery technique has demonstrated better normal tissue sparing and dose conformity than the clinically used volumetric modulated arc therapy (VMAT). It is unclear whether this is a fundamental limitation of VMAT delivery or the coplanar nature of its typical clinical plans. The dosimetry and the limits of normal tissue toxicity constrained dose escalation of coplanar VMAT, noncoplanar VMAT and 4π radiation therapy are quantified in this study. Clinical stereotactic body radiation therapy plans for 20 liver patients receiving 30 to 60 Gy using coplanar VMAT (cVMAT) were replanned using 3 to 4 partial noncoplanar arcs (nVMAT) and 4π with 20 intensity modulated noncoplanar fields. The conformity number, homogeneity index, 50% dose spillage volume, normal liver volume receiving >15 Gy, dose to organs at risk (OARs), and tumor control probability were compared for all 3 treatment plans. The maximum tolerable dose yielding a normal liver normal tissue control probability 15 Gy by an average of 5 cm3 and 80 cm3, respectively. 4π reduced the 50% dose spillage volume by ∼23% compared with both VMAT plans, and either significantly decreased or maintained OAR doses. The 4π maximum tolerable doses and survival fractions were significantly higher than both cVMAT and nVMAT (P < .05) for all normal liver normal tissue control probability limits used in this study. The 4π technique provides significantly better OAR sparing than both cVMAT and nVMAT and enables more clinically relevant dose escalation for tumor local control. Therefore, despite the current accessibility of nVMAT, it is not a viable alternative to 4π for liver SBRT.