Christos Boikos

Dr. Christos Boikos

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2023 in Atmospheric Environment
Verified
Journal Article
Closed access
CBChristos Boikos
Christos Boikos
PSPanagiotis Siamidis
Panagiotis Siamidis
SOSonia Oppo
Sonia Oppo
AAAlexandre Armengaud
Alexandre Armengaud
GTGeorge Tsegas
George Tsegas
LNLeonidas Ntziachristos
Leonidas Ntziachristos

5 October 2024 in Building and Environment
Verified
Journal Article
Closed access
CBChristos Boikos
Christos Boikos
GIGiannis Ioannidis
Giannis Ioannidis
NRNikolaos Rapkos
Nikolaos Rapkos
Georgios N TsegasGeorgios N Tsegas
Georgios N Tsegas
PKPetros Katsis
Petros Katsis
LNLeonidas Ntziachristos
Leonidas Ntziachristos

1 September 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
GIGiannis Ioannidis
Giannis Ioannidis
PTPaul Tremper
Paul Tremper
CLChaofan Li
Chaofan Li
TRTill Riedel
Till Riedel
NRNikolaos Rapkos
Nikolaos Rapkos
LNLeonidas Ntziachristos
Leonidas Ntziachristos
Assessing air quality in urban areas is vital for protecting public health, and low-cost sensor networks help quantify the population’s exposure to harmful pollutants effectively. This paper introduces an innovative method to calibrate air-quality sensor networks by combining CFD modeling with dependable AQ measurements. The developed CFD model is used to simulate traffic-related PM10 dispersion in a 1.6 × 2 km2 urban area. Hourly simulations are conducted, and the resulting concentrations are cross-validated against high-quality measurements. By offering detailed 3D information at a micro-scale, the CFD model enables the creation of concentration maps at sensor locations. Through regression analysis, relationships between low-cost sensor (LCS) readings and modeled outcomes are established and used for network calibration. The study demonstrates the methodology’s capability to provide aid to low-cost devices during a representative 24 h period. The precision of a CFD model can also guide optimal sensor placement based on prevailing meteorological and emission scenarios and refine existing networks for more accurate urban air quality representation. The usage of cost-effective air quality networks, high-quality monitoring stations, and high-resolution air quality modeling combines the strengths of both top-down and bottom-up approaches for air quality assessment. Therefore, the work demonstrated plays a significant role in providing reliable pollutant monitoring and supporting the assessment of environmental policies, aiming to address health issues related to urban air pollution.

30 April 2024 in Building and Environment
Verified
Journal Article
Closed access
CBChristos Boikos
Christos Boikos
NRNikolaos Rapkos
Nikolaos Rapkos
GIGiannis Ioannidis
Giannis Ioannidis
SOSonia Oppo
Sonia Oppo
AAAlexandre Armengaud
Alexandre Armengaud
LNLeonidas Ntziachristos
Leonidas Ntziachristos

11 December 2023 in Atmospheric Pollution Research
Verified
Journal Article
Closed access
NRNikolaos Rapkos
Nikolaos Rapkos
CBChristos Boikos
Christos Boikos
GIGiannis Ioannidis
Giannis Ioannidis
LNLeonidas Ntziachristos
Leonidas Ntziachristos

12 March 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
GIGiannis Ioannidis
Giannis Ioannidis
PTPaul Tremper
Paul Tremper
CLChaofan Li
Chaofan Li
TRTill Riedel
Till Riedel
NRNikolaos Rapkos
Nikolaos Rapkos
LNLeonidas Ntziachristos
Leonidas Ntziachristos
Densely populated urban areas often experience poor air quality due to high levels of anthropogenic emissions. The population is frequently exposed to harmful gaseous and particulate pollutants, which are directly linked to various health issues, including respiratory diseases. Accurately assessing and predicting pollutant concentrations within urban areas is therefore crucial. This study developed a computational fluid dynamic (CFD) model designed to capture turbulence effects that influence pollutant dispersion in urban environments. The focus was on key pollutants commonly associated with vehicular emissions, such as carbon monoxide (CO), nitrogen oxides (NOx), volatile organic compounds (VOCs), and particulate matter (PM). The model was applied to the city of Augsburg, Germany, to simulate pollutant behavior at a microscale level. The primary objectives were twofold: first, to accurately predict local pollutant concentrations and validate these predictions against measurement data; second, to evaluate the representativeness of air quality monitoring stations in reflecting the broader pollutant distribution in their vicinity. The approach presented here has demonstrated that when focusing on an area within a specific radius of an air quality station, the representativeness ranges between 10% and 16%. On the other hand, when assessing the representativeness across the street of deployment, the spatial coverage of the sensor ranges between 23% and 80%. This analysis highlights that air quality stations primarily capture pollution levels from high-activity areas directly across their deployment site, rather than reflecting conditions in nearby lower-activity zones. This approach ensures a more comprehensive understanding of urban air pollution dynamics and assesses the reliability of air quality (AQ) monitoring stations.