Taha mohamed Taha Ahmed

Dr. Taha mohamed Taha Ahmed

Radiation Protection, Egyptian Atomic Energy Authority, Cairo, Al Qāhirah, Egypt
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
TATaha mohamed Taha Ahmed
Taha mohamed Taha Ahmed
FAF.H. Al-Ghorabie
F.H. Al-Ghorabie
RKR.A. Kutbi
R.A. Kutbi
WSW.K. Saib
W.K. Saib
Assessment of entrance skin doses for patients in conventional diagnostic radiology examinations should be made as a means for the optimization of the radiation protection of the patients. We estimated the entrance skin dose received by patients undergoing diagnostic X-ray examinations, including the entrance skin doses for 500 patients in six types of X-ray examinations. The entrance skin dose was determined indirectly via measurements and from knowledge of X-ray output factors. We entered the measurements parameters such as X-ray dose output, back scatter factor, and focus to skin distance and we used questionnaire physical parameters such as mAs and kV in mathematical model. The mean and standard deviation for entrance skin doses for chest PA, skull AP, abdomen, C-spine, pelvic AP, hand and foot were 0.138 ± 0.04, 2.07 ± 0.12, 2.5 ± 0.140, 0.18 ± 0.11, 5.41 ± 0.33, and 0.102 ± 0.01 mGy, respectively. The results obtained were compared with the reference levels of the International Atomic Energy Agency. The entrance skin dose calculation was took into account the patient thickness. Further studies are required for minimization of radiation doses to sensitive organs

1 January 2020 in Journal of Nuclear Technology in Applied Science
Verified
Journal Article
Closed access
PDF file
TATaha mohamed Taha Ahmed
Taha mohamed Taha Ahmed
SASaud Hamed Allehyani
Saud Hamed Allehyani
AMAnas Alaa Mihdhir
Anas Alaa Mihdhir
MOMufeed Mohamed Otiabey
Mufeed Mohamed Otiabey
The current study is aimed to estimate the diagnostic reference dose levels (DRLs), the volume computer tomogram dose index (CTDIvol), the CT air kerma-length product (PKL,CT) and the effective dose (E) for head, chest and chest-abdomen-pelvic CT examinations performed on adults in King Abdullah Medical City (KAMC), Saudi Arabia. Demographic parameters (such as age, gender, weight, height) for a sample of 535 computed tomography (CT) patients and physical scan parameters (such as patient tube voltage (kV), reference and effective mill ampere-second (mAs), scan length, number of slices, and pitch factor) were collected from a picture archiving and communication system (PACS). CTDIvol and PKL,CT were studied for different patients weights (40 -60 kg, 60-80 kg, 80-100 kg and 100-120 kg). Mean CTDIvol, PKL,CT and effective dose for a standard weight (70 kg ±10%) was evaluated according to the three CT protocols considered and the results were, as follows: for head examinations – 61.8 mGy, 1212 mGy.cm and 2.55 mSv, respectively; for chest examinations- 13.1 mGy, 657.5 mGy.cm and 9.21 mSv, respectively; for chest-abdomen-pelvic examinations - 13.9 mGy, 782.5 mGy.cm and 11.73 mSv, respectively. The effective dose for the chest examinations was lower than the corresponding value communicated by the European study group under European Commission. The effective dose for head examinations, was slightly higher than the one communicated by the European Commission study due to differences in the scan length. It needs optimizing the radiation dose delivered to patients via periodical review of scan parameters for a protocol under study.

15 October 2025 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
TATaha mohamed Taha Ahmed
Taha mohamed Taha Ahmed
MEMohamed El-Ashkar
Mohamed El-Ashkar
MSMohamed Soliman
Mohamed Soliman

12 September 2022 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
TATaha mohamed Taha Ahmed
Taha mohamed Taha Ahmed
TMTarek Morsi
Tarek Morsi

5 February 2024 in Research Square
Verified
Preprint
Open access
PDF file
TATaha mohamed Taha Ahmed
Taha mohamed Taha Ahmed
TMTarek M Morsi
Tarek M Morsi
Background: Owing to the increasing use of radioisotopes whether in nuclear medicine or research. The current research paper uses a whole-body counter to assess internal contamination for individuals working in nuclear medicine and research laboratories. High purity germanium detector Whole Body Counter with a relative efficiency of 25%; aluminum endcap with 1.5 mm was calibrated using a mixed gamma source. It consists of three parts; high purity germanium detector gamma ray spectrometer, shielding room, and Phantom. Gamma internal monitoring was performed on eight volunteers inhaled with 131I and two individuals contaminated with 99mTc in organ geometry. Results: The committed effective dose for individuals was lower than dose constrain and within the dose limit according to ICRP recommendations. Conclusions: The study indicates that the HpGe whole body counter has the capability to detect organ contamination such as 131I in thyroid gland, 99mTc in whole body geometry.

9 July 2024 in Research Square
Verified
Preprint
Open access
PDF file
TATaha mohamed Taha Ahmed
Taha mohamed Taha Ahmed
There is a trend in public worldwide to use ceramic tiles in domestic decoration , monitoring the radiation risk for individuals due to used ceramic materials is needed. The current study aims at assessing the radiological impact to individuals associated with natural radioactivity levels in ceramic materials. The specific activity of natural radionuclides was measured in the investigated ceramic materials using high purity germanium detector gamma spectrometry (HPGe) with 25% coaxial efficiency. The raw materials of the ceramic are made of a mixture of bicarbonate perc, clay, feldspar, glass sand, limestone, talc, kaolin minerals, and zalouky and zirconium silicates. The Radium equivalent activity, annual effective dose, and external hazard indexes (Hex) and excess cancer life risk (ECLR) were assessed using standard protocols. The present results indicated that the annual effective dose resulting from 226Ra, 232Th, 40K is within dose constrains and lower than the public dose limit recommended by ICRP.